Intraoperative Imaging With a 3D C-Arm System After Zygomatico-Orbital Complex Fracture Reduction

被引:76
|
作者
Wilde, Frank [1 ,2 ]
Lorenz, Kai [2 ,3 ]
Ebner, Ann-Kathrin [4 ]
Krauss, Oliver [2 ,5 ]
Mascha, Frank [1 ,2 ]
Schramm, Alexander [1 ,2 ]
机构
[1] Mil Hosp Ulm, Dept Oral & Maxillofacial Surg, D-89081 Ulm, Germany
[2] Univ Ulm, Acad Hosp, D-89081 Ulm, Germany
[3] Mil Hosp Ulm, Dept Otolaryngol Head & Neck Surg, D-89081 Ulm, Germany
[4] Univ Ulm, Dept Dent, D-89081 Ulm, Germany
[5] Mil Hosp Ulm, Dept Ophthalmol, D-89081 Ulm, Germany
关键词
COMPUTED-TOMOGRAPHY; BLINDNESS; SURGERY; TRAUMA;
D O I
10.1016/j.joms.2012.10.031
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: During the repair of zygomatico-orbital complex (ZMC) fractures, the lateral orbital wall and/or the orbital floor is often reduced by merely reducing the zygoma. Intraoperative 3D imaging can help surgeons decide whether the orbit must be reconstructed as well. The purpose of this study was therefore to assess the usefulness of intraoperative 3D C-arm imaging in evaluating the adequacy of fracture reduction. Methods: A total of 21 patients with unilateral ZMC fractures were enrolled in this retrospective study. Four fractures were treated with a closed reduction technique. Seventeen fractures were repaired with open reduction and internal fixation of the zygomaticomaxillary buttress area. Intraoperative 3D C-arm imaging was performed in all cases. All patients underwent postoperative computed tomography and a clinical examination no earlier than 5 months after the procedure. Results: After reduction of the ZMC fractures, intraoperative 3D scans showed inadequate repair of the orbital floor in 2 patients and inadequate repair of the lateral orbit in 1 patient. Zygoma and zygomatic arch fracture reduction had to be corrected in 1 further case. The other 17 patients did not need an additional procedure. Postoperative imaging showed that no patient required a secondary operation. No postoperative diplopia or enophthalmos developed in any patient. Conclusions: Intraoperative 3D C-arm imaging appears to be an effective tool for evaluating ZMC fracture reduction. It helps avoid additional procedures and thus helps reduce morbidity. In addition, there appears to be no need for postoperative imaging. (C) 2013 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 71:894-910, 2013
引用
收藏
页码:894 / 910
页数:17
相关论文
共 50 条
  • [31] A method for extracting 3D information of cylinder in C-arm image
    Wu, Jian
    BMEI 2008: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOL 2, 2008, : 544 - +
  • [32] Mobile C-arm 3D Reconstruction in the Presence of Uncertain Geometry
    Rottman, Caleb
    McBride, Lance
    Cheryauka, Arvidas
    Whitaker, Ross
    Joshi, Sarang
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2015, PT II, 2015, 9350 : 692 - 699
  • [33] 3D-imaging of the facial skeleton with an isocentric mobile C-arm system (Siremobil ISO-C3D)
    Heiland, M
    Schulze, D
    Adam, G
    Schmelzle, R
    DENTOMAXILLOFACIAL RADIOLOGY, 2003, 32 (01) : 21 - 25
  • [34] 3D-imaging of the facial skeleton with an isocentric mobile C-arm system (Siremobil Iso-C3D)
    Schulze, D
    Heiland, M
    Adam, G
    Schmelzle, R
    Rother, U
    RADIOLOGY, 2002, 225 : 565 - 565
  • [35] Intraoperative imaging with the ISO C 3D [Intraoperative bildgebung mit dem ISO C 3D]
    Wich M.
    Spranger N.
    Ekkernkamp A.
    Der Chirurg, 2004, 75 (10): : 982 - 987
  • [36] A low-cost tracked C-arm (TC-arm) upgrade system for versatile quantitative intraoperative imaging
    Amiri, Shahram
    Wilson, David R.
    Masri, Bassam A.
    Anglin, Carolyn
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2014, 9 (04) : 695 - 711
  • [37] A low-cost tracked C-arm (TC-arm) upgrade system for versatile quantitative intraoperative imaging
    Shahram Amiri
    David R. Wilson
    Bassam A. Masri
    Carolyn Anglin
    International Journal of Computer Assisted Radiology and Surgery, 2014, 9 : 695 - 711
  • [38] Can Postoperative CT Imaging in Spine Surgery Be Replaced by Intraoperative 3D Rotation With the C-Arm?: Results of a Prospective Single Center Cohort Study
    Banat, Mohammed
    Wach, Johannes
    Salemdawod, Abdallah
    Domurath, Lisa
    Scorzin, Jasmin
    Vatter, Hartmut
    FRONTIERS IN SURGERY, 2021, 8
  • [39] Exact 3D cone-beam reconstruction from two short-scans using a C-arm imaging system
    Ramamurthi, K
    Strobel, N
    Prince, JL
    COMPUTATIONAL IMAGING III, 2005, 5674 : 87 - 98
  • [40] Model of a vascular C-arm for 3D augmented fluoroscopy in interventional radiology
    Gorges, S
    Kerrien, E
    Berger, MO
    Trousset, Y
    Pescatore, J
    Anxionnat, R
    Picard, L
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2005, PT 2, 2005, 3750 : 214 - 222