Effect of improper scan alignment on retinal nerve fiber layer thickness measurements using Stratus optical coherence tomograph

被引:54
|
作者
Vizzeri, Gianmarco [1 ]
Bowd, Christopher [1 ]
Medeiros, Felipe A. [1 ]
Weinreb, Robert N. [1 ]
Zangwill, Linda M. [1 ]
机构
[1] Univ Calif San Diego, Dept Ophthalmol, Hamilton Glaucoma Ctr, La Jolla, CA 92093 USA
关键词
imaging; stratus optical coherence tomography; retinal nerve fiber layer thickness; reproducibility;
D O I
10.1097/IJG.0b013e31815c3aeb
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: Misalignment of the Stratus optical coherence tomograph scan circle placed by the operator around the optic nerve head (ONH) during each retinal nerve fiber layer (RNFL) examination can affect the instrument reproducibility and its theoretical ability to detect true structural changes in the RNFL thickness over time. We evaluated the effect of scan circle placement on RNFL measurements. Design: Observational clinical study. Methods: Sixteen eyes of 8 normal participants were examined using the Stratus optical coherence tomograph Fast RNFL thickness acquisition protocol (software version 4.0.7; Carl Zeiss Meditec, Dublin, CA). Four consecutive images were taken by the same operator with the circular scan centered oil the optic nerve head. Four images each with the scan displaced superiorly, inferiorly, temporally, and nasally were also acquired. Differences in average and sectoral RNFL thicknesses were determined. For the centered scans, the coefficients of variation (CV) and the intraclass correlation coefficient for the average RNFL thickness measured were calculated. Results: When the average RNFL thickness of the centered scans was compared with the average RNFL thickness of the displaced scans individually using analysis of variance with post-hoc analysis, no difference was found between the average RNFL thickness of the nasally (105.2 mu m), superiorly (106.2 mu m), or inferiorly (104.1 mu m) displaced scans and the centered scans (106.4 mu m). However, a significant difference (analysis of variance with Dunnett's test: F = 8.82, P < 0.0001) was found between temporally displaced scans (115.8 mu m) and centered scans. Significant differences in sectoral RNFL thickness measurements were found between centered and each displaced scan. The coefficient of variation for average RNFL thickness was 1.75% and intraclass correlation coefficient was 0.95. Conclusions: In normal eyes, average RNFL thickness measurement are robust and similar with significant superior, inferior. and nasal scan displacement, but average RNFL thickness is greater when scans are displaced temporally. Parapapillary scan misalignment produces significant changes in RNFL assessment characterized by an increase in measured RNFL thickness in the quadrant in which the scan is closer to the disc, and a significant decrease in RNFL thickness in the quadrant in which the scan is displaced further from the optic disc.
引用
下载
收藏
页码:341 / 349
页数:9
相关论文
共 50 条
  • [21] Reproducibility of Retinal Nerve Fiber Layer and Macular Thickness Measurements Using Spectral Domain Optical Coherence Tomography
    Sood, Amit
    Paliwal, Rahul Omprakash
    Mishra, Rishu Yogesh
    GALICIAN MEDICAL JOURNAL, 2021, 28 (04)
  • [22] Retinal nerve fiber layer thickness measurements of normal Northern Nigerian adults using optical coherence tomography
    Sani, Rabi Yahaya
    Abdu, Lawal
    Pam, Victoria
    ANNALS OF AFRICAN MEDICINE, 2016, 15 (02) : 52 - 57
  • [23] Optical Coherence Tomography Measurements of Retinal Nerve Fiber Layer Thickness in Chinese Children and Teenagers
    Qian, Jin
    Wang, Weijun
    Zhang, Xian
    Wang, Fenghua
    Jiang, Yuan
    Wang, Wenqiu
    Xu, Shan
    Wu, Ying
    Su, Yi
    Xu, Xun
    Sun, Xiaodong
    JOURNAL OF GLAUCOMA, 2011, 20 (08) : 509 - 513
  • [24] Modelling the normal retinal nerve fibre layer thickness as measured by Stratus optical coherence tomography
    Jesper Leth Hougaard
    Carl Ostenfeld
    Anders Heijl
    Boel Bengtsson
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2006, 244 : 1607 - 1614
  • [25] Improved reproducibility of retinal nerve fiber layer thickness measurements with the repeat-scan protocol using the Stratus OCT in normal and glaucomatous eyes
    Tzamalis, Argyrios
    Kynigopoulos, Myron
    Schlote, Torsten
    Haefliger, Ivan
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2009, 247 (02) : 245 - 252
  • [26] Improved reproducibility of retinal nerve fiber layer thickness measurements with the repeat-scan protocol using the Stratus OCT in normal and glaucomatous eyes
    Argyrios Tzamalis
    Myron Kynigopoulos
    Torsten Schlote
    Ivan Haefliger
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2009, 247 : 245 - 252
  • [27] Modelling the normal retinal nerve fibre layer thickness as measured by Stratus optical coherence tomography
    Hougaard, Jesper Leth
    Ostenfeld, Carl
    Heijl, Anders
    Bengtsson, Boel
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 244 (12) : 1607 - 1614
  • [28] Impact of optical coherence tomography scan direction on the reliability of peripapillary retinal nerve fiber layer measurements
    Venkataraman, Abinaya Priya
    Andersson, Josefine
    Fivelsdal, Lina
    Nilsson, Maria
    Dominguez-Vicent, Alberto
    PLOS ONE, 2021, 16 (02):
  • [29] Influence of pupil size and cataract on retinal nerve fiber layer thickness measurements by stratus OCT
    Savini, Giacomo
    Zanini, Maurizio
    Barboni, Piero
    JOURNAL OF GLAUCOMA, 2006, 15 (04) : 336 - 340
  • [30] A robust algorithm for retinal thickness measurements using optical coherence tomography (Stratus OCT)
    Gregori, G
    Knighton, RW
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U50 - U50