Effect of improper scan alignment on retinal nerve fiber layer thickness measurements using Stratus optical coherence tomograph

被引:54
|
作者
Vizzeri, Gianmarco [1 ]
Bowd, Christopher [1 ]
Medeiros, Felipe A. [1 ]
Weinreb, Robert N. [1 ]
Zangwill, Linda M. [1 ]
机构
[1] Univ Calif San Diego, Dept Ophthalmol, Hamilton Glaucoma Ctr, La Jolla, CA 92093 USA
关键词
imaging; stratus optical coherence tomography; retinal nerve fiber layer thickness; reproducibility;
D O I
10.1097/IJG.0b013e31815c3aeb
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: Misalignment of the Stratus optical coherence tomograph scan circle placed by the operator around the optic nerve head (ONH) during each retinal nerve fiber layer (RNFL) examination can affect the instrument reproducibility and its theoretical ability to detect true structural changes in the RNFL thickness over time. We evaluated the effect of scan circle placement on RNFL measurements. Design: Observational clinical study. Methods: Sixteen eyes of 8 normal participants were examined using the Stratus optical coherence tomograph Fast RNFL thickness acquisition protocol (software version 4.0.7; Carl Zeiss Meditec, Dublin, CA). Four consecutive images were taken by the same operator with the circular scan centered oil the optic nerve head. Four images each with the scan displaced superiorly, inferiorly, temporally, and nasally were also acquired. Differences in average and sectoral RNFL thicknesses were determined. For the centered scans, the coefficients of variation (CV) and the intraclass correlation coefficient for the average RNFL thickness measured were calculated. Results: When the average RNFL thickness of the centered scans was compared with the average RNFL thickness of the displaced scans individually using analysis of variance with post-hoc analysis, no difference was found between the average RNFL thickness of the nasally (105.2 mu m), superiorly (106.2 mu m), or inferiorly (104.1 mu m) displaced scans and the centered scans (106.4 mu m). However, a significant difference (analysis of variance with Dunnett's test: F = 8.82, P < 0.0001) was found between temporally displaced scans (115.8 mu m) and centered scans. Significant differences in sectoral RNFL thickness measurements were found between centered and each displaced scan. The coefficient of variation for average RNFL thickness was 1.75% and intraclass correlation coefficient was 0.95. Conclusions: In normal eyes, average RNFL thickness measurement are robust and similar with significant superior, inferior. and nasal scan displacement, but average RNFL thickness is greater when scans are displaced temporally. Parapapillary scan misalignment produces significant changes in RNFL assessment characterized by an increase in measured RNFL thickness in the quadrant in which the scan is closer to the disc, and a significant decrease in RNFL thickness in the quadrant in which the scan is displaced further from the optic disc.
引用
下载
收藏
页码:341 / 349
页数:9
相关论文
共 50 条
  • [31] The Effect of Pupillary Dilation on Retinal Nerve Fiber Layer Thickness Measurements Taken by Spectral Domain Optical Coherence Tomography
    Cam, Duygu
    Karabag, Revan Yildirim
    Arikan, Gul
    Gunenc, Uzeyir
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2014, 44 (06): : 454 - 457
  • [32] REPRODUCIBILITY OF NERVE-FIBER LAYER THICKNESS MEASUREMENTS USING OPTICAL COHERENCE TOMOGRAPHY
    SCHUMAN, JS
    HEE, MR
    PEDUTKLOIZMAN, T
    WONG, C
    ARYA, AV
    HERTZMARK, E
    PULIAFITO, CA
    FUJIMOTO, JG
    SWANSON, EA
    IZATT, JA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S971 - S971
  • [33] Evaluation of Peripapillary Retinal Nerve Fiber Layer Thickness of Myopic and Hyperopic Patients: A Controlled Study by Stratus Optical Coherence Tomography
    Oner, Veysi
    Tas, Mehmet
    Turkcu, Fatih Mehmet
    Alakus, Mehmet Fuat
    Iscan, Yalcin
    Yazici, Ahmet Taylan
    CURRENT EYE RESEARCH, 2013, 38 (01) : 102 - 107
  • [34] Horizontal Deviation of Retinal Nerve Fiber Layer Peak Thickness With Stratus Optical Coherence Tomography in Glaucoma Patients and Glaucoma Suspects
    Lee, Jennifer C.
    Shields, Milton Bruce
    JOURNAL OF GLAUCOMA, 2010, 19 (05) : 299 - 303
  • [35] Effect of photorefractive keratectomy for myopia on measurement of retinal nerve fiber layer thickness using optical coherence tomography
    Carpineto, P
    Ciancaglini, M
    Zuppardi, E
    Doronzo, E
    Di Stefano, N
    Mastropasqua, L
    JOURNAL OF REFRACTIVE SURGERY, 2001, 17 (06) : 676 - 681
  • [36] Effect of Peripapillary Vitreous Opacity on Retinal Nerve Fiber Layer Thickness Measurement Using Optical Coherence Tomography
    Hwang, Young Hoon
    Kim, Yong Yeon
    ARCHIVES OF OPHTHALMOLOGY, 2012, 130 (06) : 789 - 792
  • [37] Factors associated with variability in retinal nerve fiber layer thickness measurements obtained by optical coherence tomography
    Wu, Ziqiang
    Vazeen, Matti
    Varma, Rohit
    Chopra, Vikas
    Walsh, Alexander C.
    LaBree, Laurie D.
    Sadda, Srinivas R.
    OPHTHALMOLOGY, 2007, 114 (08) : 1505 - 1512
  • [38] The effect of phacoemulsification cataract surgery on the measurement of retinal nerve fiber layer thickness using optical coherence tomography
    El-Ashry, Mohamed
    Appaswamy, Shivashankar
    Deokule, Sunil
    Pagliarini, Sergio
    CURRENT EYE RESEARCH, 2006, 31 (05) : 409 - 413
  • [39] Retinal nerve fiber layer thickness measurements with optical coherence tomography in glaucoma patients and healthy controls
    Mardin, Christian Yahya
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2019, 236 (06) : 784 - 790
  • [40] Retinal Nerve Fiber Layer Thickness Measurements in Rats with Spectral Domain-Optical Coherence Tomography
    Huang, Jinhai
    Savini, Giacomo
    Feng, Yifan
    Wang, Qinmei
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (02) : 749 - 750