Reproducibility of Retinal Nerve Fiber Layer and Macular Thickness Measurements Using Spectral Domain Optical Coherence Tomography

被引:0
|
作者
Sood, Amit [1 ]
Paliwal, Rahul Omprakash [2 ]
Mishra, Rishu Yogesh [3 ]
机构
[1] Autonomous State Med Coll, Dept Ophthalmol, Shahjahanpur, Uttar Pradesh, India
[2] Autonomous State Med Coll, Dept Anat, Shahjahanpur, Uttar Pradesh, India
[3] Autonomous State Med Coll, Dept Pharmacol, Shahjahanpur, Uttar Pradesh, India
关键词
Diagnostic Laboratory Technique; Reproducibility; Macular Thickness; Retinal Nerve Fiber Layer; Spectral Domain Optical Coherence Tomography; INSTRUMENTS;
D O I
10.21802/gmj.2021.4.7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The objective of the research was to assess the reproducibility of retinal nerve fiber layer (RNFL) and macular thickness using spectral domain optical coherence tomography and to establish whether the same investigator can get the same or similar results when performing the scan thrice in an hour, without reference to the previous scan and the repeat function. Materials and Methods. In this prospective observational study, 200 subjects who fulfilled the inclusion and exclusion criteria were scanned 3 times according to predefined guidelines at 0, 30 and 60 minutes on the same day, by the same investigator, using spectral domain optical coherence tomography for measurements of RNFL and macular thickness; observations were statistically analyzed and correlated. Results. In RNFL thickness, the temporal sector showed the worst reproducibility as compared to other sectors. RNFL was the greatest in the superior quadrant and the thinnest in the temporal quadrant. For macular thickness, the temporal sector (mid zone) showed the worst reproducibility, while in the outer zone, the inferior sector showed the worst reproducibility; macular thickness was the thinnest at the central zone (innermost 1-mm ring), the thickest within the inner 3-mm ring and diminished peripherally. Conclusions. RNFL and macular thickness measurements using spectral domain optical coherence tomography by the same observer at 0, 30 and 60 minutes were very reproducible, except for the sectors specifically mentioned. The greater the thickness of the RNFL in any sector the better was the reproducibility in that sector. For macular thickness, the temporal sector (mid zone) showed the worst reproducibility.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Reproducibility of Retinal Nerve Fiber Layer Thickness Measurements Using Spectral Domain Optical Coherence Tomography
    Wu, Huijuan
    de Boer, Johannes F.
    Chen, Teresa C.
    [J]. JOURNAL OF GLAUCOMA, 2011, 20 (08) : 470 - 476
  • [2] Reproducibility of Retinal Nerve Fiber Thickness Measurements Using Spectral-Domain Optical Coherence Tomography in Glaucoma Patients
    Monsalve, B.
    Ferreras, A.
    Pajarin, A. B.
    Pablo, L. E.
    Urcelay, J. L.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [3] Comparison of Time Domain and Spectral Domain Optical Coherence Tomography in Retinal Nerve Fiber Layer Thickness Measurements
    Bhartiya, S.
    Kumar, M.
    Kumar, V.
    Khanduja, S.
    Mishra, S. K.
    Dada, T.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [4] Reproducibility of corneal, macular and retinal nerve fiber layer thickness measurements using the iVue-100 optical coherence tomography
    Mashige, Khathutshelo P.
    [J]. AFRICAN HEALTH SCIENCES, 2017, 17 (04) : 1222 - 1228
  • [5] Retinal Nerve Fiber Layer Thickness Measurements in Rats with Spectral Domain-Optical Coherence Tomography
    Huang, Jinhai
    Savini, Giacomo
    Feng, Yifan
    Wang, Qinmei
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (02) : 749 - 750
  • [6] Effects of Misalignments in the Retinal Nerve Fiber Layer Thickness Measurements with Spectral Domain Optical Coherence Tomography
    Barella, Kleyton A.
    Cremasco, Fernanda
    Zangalli, Camila
    Costa, Vital P.
    [J]. JOURNAL OF OPHTHALMOLOGY, 2014, 2014
  • [7] Reproducibility of nerve fiber layer thickness measurements using optical coherence tomography
    Schuman, JS
    PedutKloizman, T
    Hertzmark, E
    Hee, MR
    Wilkins, JR
    Coker, JG
    Puliafito, CA
    Fujimoto, JG
    Swanson, EA
    [J]. OPHTHALMOLOGY, 1996, 103 (11) : 1889 - 1898
  • [8] Reproducibility of nerve fiber layer thickness measurements using Optical Coherence Tomography
    Williams, JM
    Zangwill, LM
    Berry, CC
    Blumenthal, E
    Girkin, C
    Weinreb, RN
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S75 - S75
  • [9] Normative spectral domain optical coherence tomography data on macular and retinal nerve fiber layer thickness in Indians
    Appukuttan, Bindu
    Giridhar, Anantharaman
    Gopalakrishnan, Mahesh
    Sivaprasad, Sobha
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2014, 62 (03) : 316 - 321
  • [10] Reproducibility of Retinal Nerve Fiber Layer and Macular Ganglion Cell Layer Thickness Measurements by Optical Coherence Tomography in Myopic Eyes
    Park, Sang Min
    Lee, Kwan Bok
    Kim, Kyoung Nam
    Hwang, Young Hoon
    [J]. JOURNAL OF GLAUCOMA, 2021, 30 (09) : 834 - 838