Voltage Controlled Oscillator with Impedance Spectroscopy for Non-invasive Glucose Application

被引:1
|
作者
Lai, Wen-Cheng [1 ]
Jang, Sheng-Lyang
Wang, Jyun-Jhih
机构
[1] Natl Taiwan Univ Sci & Technol, Dept Elect Engn, Taipei, Taiwan
关键词
triple phase; class C VCO; current reuse; back gate coupling; impedance spectroscopy; non-invasive glucose application; PHASE-NOISE; COLPITTS VCO; DESIGN;
D O I
10.1109/ISM.2018.00013
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A new three-phase voltage controlled oscillator (VCO) implemented in TSMC 0.18 mu m 1P6M CMOS process. The designed VCO consists of three single-ended current-reused VCOs coupled via a back gate coupling to reduce the power consumption for impedance spectroscopy sensor. Tuning range of VCO is 0.689 GHz, from 4.45 GHz to 5.14 GHz, while the control voltage was tuned from OV to 1.8V and the VCO core power consumption is 4mW at the supply voltage of 1 V. The measured phase noise is -128.08 dBc/Hz at 1MHz offset frequency from 4.46 GHz. The VCO occupies a chip area of 1.000x0.772mm(2) and provides a figure of merit of -195.05 dBc/Hz setup in non-invasive glucose application.
引用
收藏
页码:25 / 28
页数:4
相关论文
共 50 条
  • [41] Non-invasive obstetric anal sphincter injury diagnostics using impedance spectroscopy
    Katarzyna Borycka-Kiciak
    Marcel Młyńczak
    Adam Kiciak
    Piotr Pietrzak
    Adam Dziki
    [J]. Scientific Reports, 9
  • [42] Non invasive glucose monitoring using a multisensor concept based on impedance spectroscopy
    Caduff, Andreas
    Talary, Mark
    Donath, Marc
    Klisic, Jelena
    [J]. DIABETES, 2007, 56 : A106 - A106
  • [43] Non-invasive Blood Glucose Measurement Based on mid-Infrared Spectroscopy
    Chen, Yang
    Liu, Jiang
    Pan, Zhenni
    Shimamoto, Shirgeru
    [J]. 2020 IEEE 17TH ANNUAL CONSUMER COMMUNICATIONS & NETWORKING CONFERENCE (CCNC 2020), 2020,
  • [44] Influence of cholesterol on non-invasive blood glucose sensing studied with NIR spectroscopy
    Jiang, Jingying
    Zhang, Lingling
    Gong, Qiliang
    Xu, Kexin
    [J]. DYNAMICS AND FLUCTUATIONS IN BIOMEDICAL PHOTONICS VIII, 2011, 7898
  • [45] Non-invasive tracking and monitoring glucose content using near infrared spectroscopy
    Tamilselvi, M.
    Ramkumar, G.
    [J]. 2015 IEEE INTERNATIONAL CONFERENCE ON COMPUTATIONAL INTELLIGENCE AND COMPUTING RESEARCH (ICCIC), 2015, : 847 - 849
  • [46] Non-invasive blood glucose monitoring with Raman spectroscopy: prospects for device miniaturization
    Wrobel, M. S.
    [J]. 39TH INTERNATIONAL MICROELECTRONICS AND PACKAGING IMAPS POLAND 2015 CONFERENCE, 2016, 104
  • [47] Instrumental Requirements for Non-Invasive Blood Glucose Measurement Using NIR Spectroscopy
    Hidenobu Arimoto
    Masatoshi Tarumi
    Yukio Yamada
    [J]. Optical Review, 2003, 10 : 161 - 165
  • [48] Clinical chemistry and near infrared spectroscopy: technology for non-invasive glucose monitoring
    Heise, HM
    Bittner, A
    Marbach, R
    [J]. JOURNAL OF NEAR INFRARED SPECTROSCOPY, VOL 6 1998, 1998, : 349 - 359
  • [49] Instrumental requirements for non-invasive blood glucose measurement using NIR spectroscopy
    Arimoto, H
    Tarumi, M
    Yamada, Y
    [J]. OPTICAL REVIEW, 2003, 10 (03) : 161 - 165
  • [50] Research of transmissive near infrared spectroscopy for non-invasive blood glucose measurement
    Yang, Wenming
    Liao, Ningfang
    Li, Yasheng
    Shao, Liwei
    Huang, Dehuang
    [J]. OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS VII, 2017, 0024