Voltage Controlled Oscillator with Impedance Spectroscopy for Non-invasive Glucose Application

被引:1
|
作者
Lai, Wen-Cheng [1 ]
Jang, Sheng-Lyang
Wang, Jyun-Jhih
机构
[1] Natl Taiwan Univ Sci & Technol, Dept Elect Engn, Taipei, Taiwan
关键词
triple phase; class C VCO; current reuse; back gate coupling; impedance spectroscopy; non-invasive glucose application; PHASE-NOISE; COLPITTS VCO; DESIGN;
D O I
10.1109/ISM.2018.00013
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A new three-phase voltage controlled oscillator (VCO) implemented in TSMC 0.18 mu m 1P6M CMOS process. The designed VCO consists of three single-ended current-reused VCOs coupled via a back gate coupling to reduce the power consumption for impedance spectroscopy sensor. Tuning range of VCO is 0.689 GHz, from 4.45 GHz to 5.14 GHz, while the control voltage was tuned from OV to 1.8V and the VCO core power consumption is 4mW at the supply voltage of 1 V. The measured phase noise is -128.08 dBc/Hz at 1MHz offset frequency from 4.46 GHz. The VCO occupies a chip area of 1.000x0.772mm(2) and provides a figure of merit of -195.05 dBc/Hz setup in non-invasive glucose application.
引用
收藏
页码:25 / 28
页数:4
相关论文
共 50 条
  • [21] On Non-Invasive Glucose Measurements
    Aroutiounian, V. M.
    [J]. JOURNAL OF CONTEMPORARY PHYSICS-ARMENIAN ACADEMY OF SCIENCES, 2022, 57 (04) : 405 - 416
  • [22] Non-invasive glucose monitoring
    Arnold, MA
    [J]. CURRENT OPINION IN BIOTECHNOLOGY, 1996, 7 (01) : 46 - 49
  • [23] On Non-Invasive Glucose Measurements
    V. M. Aroutiounian
    [J]. Journal of Contemporary Physics (Armenian Academy of Sciences), 2022, 57 : 405 - 416
  • [24] Skin Impedance Measurement in Wearable Non-invasive Optical Blood Glucose Monitors
    Li, C.K.
    Tsai, Chih Wei
    [J]. 2020 2nd IEEE International Workshop on System Biology and Biomedical Systems, SBBS 2020, 2020,
  • [25] Skin Impedance Measurement in Wearable Non-invasive Optical Blood Glucose Monitors
    Li, C. K.
    Tsai, Chih Wei
    [J]. 2020 2ND IEEE INTERNATIONAL WORKSHOP ON SYSTEM BIOLOGY AND BIOMEDICAL SYSTEMS (SBBS), 2020,
  • [26] Review of Stratum Corneum Impedance Measurement in Non-Invasive Penetration Application
    Lu, Fei
    Wang, Chenshuo
    Zhao, Rongjian
    Du, Lidong
    Fang, Zhen
    Guo, Xiuhua
    Zhao, Zhan
    [J]. BIOSENSORS-BASEL, 2018, 8 (02):
  • [27] Differential Continuous Wave Photoacoustic Spectroscopy for Non-Invasive Glucose Monitoring
    Tanaka, Yujiro
    Tajima, Takuro
    Seyama, Michiko
    Waki, Kayo
    [J]. IEEE SENSORS JOURNAL, 2020, 20 (08) : 4453 - 4458
  • [28] Non-invasive blood glucose in vivo detection based on photoacoustic spectroscopy
    Lü P.-F.
    Lu Z.-Q.
    He Q.-Z.
    Wang Q.
    Zhao H.
    [J]. Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2019, 27 (06): : 1301 - 1308
  • [29] In vivo wearable non-invasive glucose monitoring based on dielectric spectroscopy
    Liu, Yuhang
    Xia, Meng
    Nie, Zedong
    Li, Jingzhen
    Zeng, Yicheng
    Wang, Lei
    [J]. PROCEEDINGS OF 2016 IEEE 13TH INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING (ICSP 2016), 2016, : 1388 - 1391
  • [30] Non-Invasive Blood Glucose Monitor Based on Spectroscopy Using a Smartphone
    Dantu, Vishnu
    Vempati, Jagannadh
    Srivilliputhur, Srinivasan
    [J]. 2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 3695 - 3698