Voltage Controlled Oscillator with Impedance Spectroscopy for Non-invasive Glucose Application

被引:1
|
作者
Lai, Wen-Cheng [1 ]
Jang, Sheng-Lyang
Wang, Jyun-Jhih
机构
[1] Natl Taiwan Univ Sci & Technol, Dept Elect Engn, Taipei, Taiwan
关键词
triple phase; class C VCO; current reuse; back gate coupling; impedance spectroscopy; non-invasive glucose application; PHASE-NOISE; COLPITTS VCO; DESIGN;
D O I
10.1109/ISM.2018.00013
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A new three-phase voltage controlled oscillator (VCO) implemented in TSMC 0.18 mu m 1P6M CMOS process. The designed VCO consists of three single-ended current-reused VCOs coupled via a back gate coupling to reduce the power consumption for impedance spectroscopy sensor. Tuning range of VCO is 0.689 GHz, from 4.45 GHz to 5.14 GHz, while the control voltage was tuned from OV to 1.8V and the VCO core power consumption is 4mW at the supply voltage of 1 V. The measured phase noise is -128.08 dBc/Hz at 1MHz offset frequency from 4.46 GHz. The VCO occupies a chip area of 1.000x0.772mm(2) and provides a figure of merit of -195.05 dBc/Hz setup in non-invasive glucose application.
引用
收藏
页码:25 / 28
页数:4
相关论文
共 50 条
  • [1] Non-invasive glucose monitoring using impedance spectroscopy
    Narasimham, Shruti
    Kaila, Gaurav
    Anand, Sneh
    [J]. INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2014, 14 (03) : 225 - 232
  • [2] Review of non-invasive continuous glucose monitoring based on impedance spectroscopy
    Huang, Jiamei
    Zhang, Ying
    Wu, Jayne
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2020, 311
  • [3] Non-invasive glucose monitoring in patients with diabetes: A novel system based on impedance spectroscopy
    Caduff, A.
    Dewarrat, F.
    Talary, M.
    Stalder, G.
    Heinemann, L.
    Feldman, Yu.
    [J]. BIOSENSORS & BIOELECTRONICS, 2006, 22 (05): : 598 - 604
  • [4] Application of Terahertz Pulsed Spectroscopy for the Development of Non-invasive Glucose Measuring Method
    Gusev, S. I.
    Guseva, V. A.
    Simonova, A. A.
    Demchenko, P. S.
    Sedykh, E. A.
    Cherkasova, O. P.
    Khodzitsky, M. K.
    [J]. 2017 PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM - SPRING (PIERS), 2017, : 3229 - 3232
  • [5] In vivo life sign application of dielectric spectroscopy and non-invasive glucose monitoring
    Talary, Mark S.
    Dewarrat, Francois
    Huber, Daniel
    Caduff, Andreas
    [J]. JOURNAL OF NON-CRYSTALLINE SOLIDS, 2007, 353 (47-51) : 4515 - 4517
  • [6] Non-invasive Blood Glucose Measurement based on Impedance Spectrum
    Yin, Tong
    Chen, Xiaoyan
    Du, Meng
    Yin, Hongyi
    [J]. JOURNAL OF ROBOTICS NETWORKING AND ARTIFICIAL LIFE, 2020, 6 (04): : 246 - 249
  • [7] Non-invasive impedance based continuous glucose monitoring system
    Talary, M. S.
    Dewarrat, F.
    Huber, D.
    Falco-Jonasson, L.
    Caduff, A.
    [J]. 13TH INTERNATIONAL CONFERENCE ON ELECTRICAL BIOIMPEDANCE AND THE 8TH CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY 2007, 2007, 17 : 636 - +
  • [8] NIR Photoacoustic Spectroscopy for Non-Invasive Glucose Measurement
    Pai, Praful P.
    Sanki, Pradyut Kumar
    De, Arijit
    Banerjee, Swapna
    [J]. 2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 7978 - 7981
  • [9] Non-invasive assessment of radiation injury with electrical impedance spectroscopy
    Osterman, KS
    Hoopes, PJ
    DeLorenzo, C
    Gladstone, DJ
    Paulsen, KD
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (05): : 665 - 683
  • [10] A 1mW Time Constant Based Impedance Spectroscopy for Non-Invasive Blood Glucose Monitoring
    Hina, Aminah
    Saadeh, Wala
    [J]. 2021 1ST INTERNATIONAL CONFERENCE ON MICROWAVE, ANTENNAS & CIRCUITS (ICMAC), 2021,