Precision and reproducibility of measurements of human corneal thickness with rapid optical low-coherence reflectometry (OLCR)

被引:28
|
作者
Böhnke, M [1 ]
Masters, BR
Wälti, R
Ballif, JJ
Chavanne, P
Gianotti, R
Salathé, RP
机构
[1] Univ Bern, Dept Ophthalmol, CH-3010 Bern, Switzerland
[2] Swiss Fed Inst Technol, Appl Opt Lab, CH-1015 Lausanne, Switzerland
关键词
optical low-coherence reflectometry; human corneal thickness; precision and reproducibility of corneal pachometry;
D O I
10.1117/1.429901
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This study investigates the precision and intraindividual variability of a Clinical optical pachometer based on low-coherence reflectometry, which was used to measure the central thickness of a human cornea in vivo. The instrument, attached to a slit lamp, is a single mode fiber optic based Michelson interferometer with a high repetition rate as previously described. The same operator performed ten sets of measurements on the same subject, each consisting of 20 consecutive scans, on each day for three consecutive days. By computing the means from every scan series, the thickness of the central cornea with optical pachometry was found to be 519.6 +/- 1.2 (range 518-521) mu m on day 1, 519.9 +/- 0.9 (range 519-521) mu m on day 2, and 523.8 +/- 0.65 (range 523-525) mu m on day 3. The thickness values on day 3, where the subject suffered from a cold without clinical ocular involvement, were different from the two precious days (p < 0.001, one way analysis of variance). Optical low-coherence reflectometry measurements of corneal thickness can be performed with high precision of about 1 mu m and a high intra- and intersession reproducibility. (C) 1999 Society of Photo-Optical Instrumentation Engineers. [S1083-3668(99)01301-5].
引用
收藏
页码:152 / 156
页数:5
相关论文
共 50 条
  • [21] Multilayer optical storage by low-coherence reflectometry
    Chinn, SR
    Swanson, EA
    OPTICS LETTERS, 1996, 21 (12) : 899 - 901
  • [22] MEASUREMENT OF CORNEAL THICKNESS BY LOW-COHERENCE INTERFEROMETRY
    HITZENBERGER, CK
    APPLIED OPTICS, 1992, 31 (31): : 6637 - 6642
  • [23] Measurement of corneal thickness by low coherence reflectometry
    Bohnke, M
    Walti, R
    Lindgren, F
    Gianotti, R
    Bonvin, P
    Salathe, RP
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1998, 212 (05) : 367 - 371
  • [24] Rapid and scalable scans at 21 m/s in optical low-coherence reflectometry
    Ballif, J
    Gianotti, R
    Chavanne, P
    Walti, R
    Salathe, RP
    OPTICS LETTERS, 1997, 22 (11) : 757 - 759
  • [25] Rapid and scalable scans at 21 m/s in optical low-coherence reflectometry
    Ecole Polytechnique, Lausanne, Switzerland
    Opt Lett, 11 (757-759):
  • [27] Correlation of Choroidal Thickness and Volume Measurements with Axial Length and Age Using Swept Source Optical Coherence Tomography and Optical Low-Coherence Reflectometry
    Michalewski, Janusz
    Michalewska, Zofia
    Nawrocka, Zofia
    Bednarski, Maciej
    Nawrocki, Jerzy
    BIOMED RESEARCH INTERNATIONAL, 2014, 2014
  • [28] Comparison of Anterior Segment Measurements with Optical Low-coherence Reflectometry and Partial-coherence Interferometry Optical Biometers
    Can, Ertugrul
    Duran, Mustafa
    Cetinkaya, Tugba
    Ariturk, Nursen
    MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2016, 23 (04) : 288 - 292
  • [29] BRAGG GRATING CHARACTERIZATION BY OPTICAL LOW-COHERENCE REFLECTOMETRY
    LAMBELET, P
    FONJALLAZ, PY
    LIMBERGER, HG
    SALATHE, RP
    ZIMMER, C
    GILGEN, HH
    IEEE PHOTONICS TECHNOLOGY LETTERS, 1993, 5 (05) : 565 - 567
  • [30] MULTIPLEXED SENSING USING OPTICAL LOW-COHERENCE REFLECTOMETRY
    SORIN, WV
    BANEY, DM
    IEEE PHOTONICS TECHNOLOGY LETTERS, 1995, 7 (08) : 917 - 919