Precision and reproducibility of measurements of human corneal thickness with rapid optical low-coherence reflectometry (OLCR)

被引:28
|
作者
Böhnke, M [1 ]
Masters, BR
Wälti, R
Ballif, JJ
Chavanne, P
Gianotti, R
Salathé, RP
机构
[1] Univ Bern, Dept Ophthalmol, CH-3010 Bern, Switzerland
[2] Swiss Fed Inst Technol, Appl Opt Lab, CH-1015 Lausanne, Switzerland
关键词
optical low-coherence reflectometry; human corneal thickness; precision and reproducibility of corneal pachometry;
D O I
10.1117/1.429901
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This study investigates the precision and intraindividual variability of a Clinical optical pachometer based on low-coherence reflectometry, which was used to measure the central thickness of a human cornea in vivo. The instrument, attached to a slit lamp, is a single mode fiber optic based Michelson interferometer with a high repetition rate as previously described. The same operator performed ten sets of measurements on the same subject, each consisting of 20 consecutive scans, on each day for three consecutive days. By computing the means from every scan series, the thickness of the central cornea with optical pachometry was found to be 519.6 +/- 1.2 (range 518-521) mu m on day 1, 519.9 +/- 0.9 (range 519-521) mu m on day 2, and 523.8 +/- 0.65 (range 523-525) mu m on day 3. The thickness values on day 3, where the subject suffered from a cold without clinical ocular involvement, were different from the two precious days (p < 0.001, one way analysis of variance). Optical low-coherence reflectometry measurements of corneal thickness can be performed with high precision of about 1 mu m and a high intra- and intersession reproducibility. (C) 1999 Society of Photo-Optical Instrumentation Engineers. [S1083-3668(99)01301-5].
引用
收藏
页码:152 / 156
页数:5
相关论文
共 50 条
  • [41] Comparison of preoperative and postoperative measurements of optical low-coherence reflectometry biometry and assessment of its refractive predictability
    İrfan Akalın
    Melek Tüfek
    Mustafa Türkyılmaz
    Faruk Öztürk
    [J]. International Ophthalmology, 2019, 39 : 1337 - 1343
  • [42] Optical low-coherence reflectometry with resolution beyond the Fourier transform limit
    Lu, CW
    Tsai, MT
    Wang, YM
    Chen, SF
    Kiang, YW
    Yang, CC
    [J]. OPTICS COMMUNICATIONS, 2006, 259 (01) : 281 - 285
  • [43] Distributed measurements of fiber birefringence and diametric load using optical low-coherence reflectometry and fiber gratings
    Coric, Dragan
    Limberger, Hans G.
    Salathe, Rene P.
    [J]. OPTICS EXPRESS, 2006, 14 (24): : 11804 - 11813
  • [44] MEASUREMENT OF OPTICAL-PROPERTIES OF BIOLOGICAL TISSUES BY LOW-COHERENCE REFLECTOMETRY
    SCHMITT, JM
    KNUTTEL, A
    BONNER, RF
    [J]. APPLIED OPTICS, 1993, 32 (30): : 6032 - 6042
  • [45] Comparison of preoperative and postoperative measurements of optical low-coherence reflectometry biometry and assessment of its refractive predictability
    Akalin, Irfan
    Tufek, Melek
    Turkyilmaz, Mustafa
    Ozturk, Faruk
    [J]. INTERNATIONAL OPHTHALMOLOGY, 2019, 39 (06) : 1337 - 1343
  • [46] Low-Coherence Reflectometry for Refractive Index Measurements of Cells in Micro-Capillaries
    Carpignano, Francesca
    Rigamonti, Giulia
    Mazzini, Giuliano
    Merlo, Sabina
    [J]. SENSORS, 2016, 16 (10)
  • [47] Comparison of total keratometry with corneal power measured by optical low-coherence reflectometry and placido-dual Scheimpflug system
    Kommineni, Usha Bhanu
    Mohamed, Ashik
    Vaddavalli, Pravin K.
    Reddy, Jagadesh C.
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2022, 32 (03) : 1496 - 1503
  • [48] Assessment of central corneal thickness using OCT, ultrasound, optical low coherence reflectometry and Scheimpflug pachymetry
    Beutelspacher, Sven C.
    Serbecic, Nermin
    Scheuerle, Alexander F.
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2011, 21 (02) : 132 - 137
  • [49] Meta-analysis of optical low-coherence reflectometry versus partial coherence interferometry biometry
    Huang, Jinhai
    McAlinden, Colm
    Huang, Yingying
    Wen, Daizong
    Savini, Giacomo
    Tu, Ruixue
    Wang, Qinmei
    [J]. SCIENTIFIC REPORTS, 2017, 7 : 1 - 10
  • [50] Uncertainties on distance and chromatic dispersion measurement using optical low-coherence reflectometry
    Obaton, A-F
    Quoix, A.
    Dubard, J.
    [J]. METROLOGIA, 2008, 45 (01) : 83 - 92