Can An EPID Be Commissioned for Multi-Met SRS Pre-Treatment VMAT QA?

被引:0
|
作者
Raxter, D. [1 ]
Litzenberg, D. [2 ]
Moran, J. [3 ]
机构
[1] Univ Toledo, 2801 W Bancroft St, Toledo, OH 43606 USA
[2] Univ Michigan, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Med Ctr, Ann Arbor, MI USA
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PO-GePV-T-
引用
收藏
页码:E606 / E606
页数:1
相关论文
共 50 条
  • [1] Confidence in VMAT EPID pre-treatment QA
    Monti, A. F.
    Trombetta, L.
    Brambilla, M. G.
    Carbonini, C.
    Torresin, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S170 - S170
  • [2] Linking VMAT pre-treatment QA and patient treatment QA by EPID dosimetry
    Sassowsky, M.
    Manser, P.
    Fix, M. K.
    Frauchiger, D.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2012, 188 (08) : 754 - 754
  • [3] Use of a commercial EPID dosimetry system in VMAT pre-treatment QA
    Parisotto, M.
    Carbonini, C.
    Brambilla, M. G.
    Monti, A. F.
    Ferrari, M. B.
    Zanni, D.
    Torresin, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S164 - S165
  • [4] Independent verification of gantry angle for pre-treatment VMAT QA using EPID
    Adamson, Justus
    Wu, Qiuwen
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (20): : 6587 - 6600
  • [5] A High Resolution Pre-Treatment VMAT QA Technique Based On EPID for Single Isocenter Multiple Mets Stereotactic Radiosurgery
    Wu, Q.
    Adamson, J.
    Liang, B.
    Liu, B.
    Zhou, F.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3685 - 3685
  • [6] Time dependent pre-treatment EPID dosimetry for standard and FFF VMAT
    Podesta, Mark
    Nijsten, Sebastiaan M. J. J. G.
    Persoon, Lucas C. G. G.
    Scheib, Stefan G.
    Baltes, Christof
    Verhaegen, Frank
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (16): : 4749 - 4768
  • [7] Patient Specific Pre-treatment QA Verification using an EPID Approach
    Quino, Luis A. Vazquez
    Chen, Xiaoming
    Fitzpatrick, Mathew
    Shi, Chengyu
    Stathakis, Sotirios
    Gutierrez, Alonso
    Esquivel, Carlos
    Mavroidis, Panayiotis
    Alkhatib, Hassan
    Papanikolaou, Niko
    [J]. TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2014, 13 (01) : 1 - 10
  • [8] Comparison of Single-Iso VMAT Vs Multi-Iso Dynamic Conformal Arc for Multi-Met SRS Plans
    Dwivedi, A.
    Ip, W.
    McGarry, T.
    Bond, L.
    Braver, J.
    Biswal, N.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E657 - E657
  • [9] A model-based 3D patient-specific pre-treatment QA method for VMAT using the EPID
    McCowan, P. M.
    Asuni, G.
    van Beek, T.
    van Uytven, E.
    Kujanpaa, K.
    McCurdy, B. M. C.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (04): : 1600 - 1612
  • [10] Performance Characterization and Clinical Implementation of IQM for Pre-treatment QA of VMAT
    Farrokhkish, Makan
    Heaton, Robert
    Norrlinger, Bern
    Wang, Yinkun
    Islam, Mohammad
    [J]. MEDICAL PHYSICS, 2019, 46 (11) : 5376 - 5376