Comparison of Single-Iso VMAT Vs Multi-Iso Dynamic Conformal Arc for Multi-Met SRS Plans

被引:0
|
作者
Dwivedi, A. [1 ,2 ]
Ip, W. [1 ]
McGarry, T. [1 ]
Bond, L. [1 ,2 ]
Braver, J. [1 ,2 ]
Biswal, N. [1 ,2 ]
机构
[1] Robert Wood Johnson Univ Hosp Somerset, Steeplechase Canc Ctr, Somerville, NJ USA
[2] Rutgers Canc Inst New Jersey, New Brunswick, NJ USA
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PO-GePV-T-
引用
收藏
页码:E657 / E657
页数:1
相关论文
共 22 条
  • [1] Brain Metastases SRS: Single-isocentre VMAT vs Multi-isocentre Dynamic Conformal Arc
    Leung, P. C. L.
    Lee, M. C. H.
    Wu, P. Y.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S2097 - S2097
  • [2] Can An EPID Be Commissioned for Multi-Met SRS Pre-Treatment VMAT QA?
    Raxter, D.
    Litzenberg, D.
    Moran, J.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E606 - E606
  • [3] Evaluating Plan Quality for Multitarget Brain Tumors: Single Iso Multi Target Vs Single Iso Single Target Plans
    Byrne, J.
    Salari, E.
    Parsai, E.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E387 - E387
  • [4] Compressive HDR Light Field Imaging Using a Single Multi-ISO Sensor
    Miandji, Ehsan
    Nguyen, Hoai-Nam
    Hajisharif, Saghi
    Unger, Jonas
    Guillemot, Christine
    [J]. IEEE TRANSACTIONS ON COMPUTATIONAL IMAGING, 2021, 7 : 1369 - 1384
  • [5] Towards Automated Application of Conformal Arc Informed VMAT (CAVMAT) for SRS of Multi-Metastasis
    Gude, Z.
    Adamson, J.
    Cullom, E.
    Zhang, J.
    Giles, W.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E388 - E388
  • [6] Application of Intensity Modulated Arc Therapy (IMAT) with Multi-ISO Planning Method to Sparing of Organs at Risk
    Bai, W.
    Gao, Y.
    Zhang, W.
    Dong, Z.
    Zhao, D.
    Yang, H.
    Zhang, R.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [7] SRS of multi brain mets using a novel single-isocenter approach: a comparison with standard SRS, VMAT and Gammaknife
    Todorovic, M.
    Matnjani, G.
    Kretschmer, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S781 - S781
  • [8] Machine Off-Isocenter Winston-Lutz Test in Single-Iso Multi-Mets Intracranial Stereotactic Radiosurgery
    Hu, D.
    Ruan, C.
    Cail, D.
    Bredfeldt, J.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [9] An Auto-Modified PTV Method to Improve Conformity for Single Isocenter Multiple Lesions SRS Conformal Dynamic Arc Plans
    Fu, L.
    Liu, H.
    Yu, Y.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E656 - E656
  • [10] VMAT vs. dynamic conformal arc technique in radiosurgery. A comparison of absorbed dose in the healthy brain tissue
    Garcia Castejon, M. A.
    Penedo Cobos, J. M.
    Perez Casas, A. M.
    Olivera Vegas, J.
    Rincon Perez, M.
    Gomez Tejedor, S.
    Muniz Igneson, J.
    Prieto Munoz, I.
    Gonzalez Abad, R.
    Ayerbe Gracia, J.
    Vara Santos, J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S771 - S772