Are conventional reconstruction plates equivalent to precontoured locking plates for distal humerus fracture fixation? A biomechanics cadaver study

被引:30
|
作者
Koonce, Ryan C. [1 ]
Baldini, Todd H. [2 ]
Morgan, Steven J. [3 ]
机构
[1] Skagit Reg Clin, Mt Vernon, WA 98274 USA
[2] Univ Colorado, Sch Med, Dept Orthopaed Surg, Aurora, CO 80045 USA
[3] Swedish Med Ctr, MOTUS Orthopaed, Englewood, CO 80113 USA
关键词
Humerus fracture; Fixation; Locking plate; Biomechanics; Cadaver; PLATING SYSTEMS; PARALLEL;
D O I
10.1016/j.clinbiomech.2012.03.008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: The optimal plate type and configuration for distal humerus fracture fixation has yet to be defined. Available biomechanical studies show conflicting results. No existing studies compare conventional reconstruction plates to newer precontoured distal humerus locking plates in both parallel and perpendicular configurations. Methods: Three groups of humerus specimens were compared via biomechanical testing in a cadaver model simulating metaphyseal comminution. Group 1 consisted of conventional reconstruction plates in a perpendicular configuration. Group 2 used precontoured locking plates in a perpendicular configuration. Group 3 used precontoured locking plates in a parallel configuration. Each group was tested for stiffness in anterior bending, posterior bending, axial compression, and torsion. The specimens then underwent cyclic loading followed by single load to failure in posterior bending. Findings: There was no significant difference between the three groups for anterior bending, posterior bending, axial compression, or torsional stiffness. There was no significant difference in load to failure for any of the three groups. Screw loosening was significantly higher in Group 1 when compared to Groups 2 and 3 after cyclic loading. Interpretation: In the early postoperative period, less expensive perpendicular conventional reconstruction plate constructs provide similar stiffness and load to failure properties to newer precontoured locking plate systems regardless of plate configuration. (c) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:697 / 701
页数:5
相关论文
共 50 条
  • [31] Length of Plates and Number of Screws for the Fixation of Distal Humerus Fractures: A Finite Element Biomechanical Study
    Zarifian, Ahmadreza
    Fough, Ali Akbarinezhad
    Eygendaal, Denise
    Rivlin, Michael
    Shaegh, Seyed Ali Mousavi
    Kachooei, Amir R.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2022, 47 (07): : 690.e1 - 690.e11
  • [32] Volar versus dorsal locking plates with and without radial styloid locking plates for the fixation of dorsally comminuted distal radius fractures: A biomechanical study in cadavers
    Blythe, Murray
    Stoffel, Karl
    Jarrett, Paul
    Kuster, Markus
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (10): : 1587 - 1593
  • [33] Distal radius fracture fixation with volar locking plates and additional bone augmentation in osteoporotic bone: a biomechanical study in a cadaveric model
    F. Högel
    S. Mair
    S. Eberle
    P. Weninger
    G. von Oldenburg
    P. Augat
    Archives of Orthopaedic and Trauma Surgery, 2013, 133 : 51 - 57
  • [34] Distal radius fracture fixation with volar locking plates and additional bone augmentation in osteoporotic bone: a biomechanical study in a cadaveric model
    Hoegel, F.
    Mair, S.
    Eberle, S.
    Weninger, P.
    von Oldenburg, G.
    Augat, P.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2013, 133 (01) : 51 - 57
  • [35] The potential of bioresorbable plates and screws in distal radius fracture fixation
    Rikli, DA
    Curtis, R
    Schilling, C
    Goldhahn, J
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2002, 33 : 77 - 83
  • [36] Fixation of Transverse Acetabular Fractures With Precontoured Plates Alone Causes Fracture Malreduction: A Biomechanical Assessment
    Alfonso, Nicholas A.
    Ryan, Weston
    Baldini, Todd
    Reiter, Michael
    Joyce, Christopher
    Mauffrey, Cyril
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2020, 34 (02) : 89 - 94
  • [37] Posterior Acetabular Fracture Fixation Using Locking Reconstruction Plates New Technique Developed on Synthetic Models
    Tadros, Ayman M. A.
    TECHNIQUES IN ORTHOPAEDICS, 2011, 26 (01) : 50 - 52
  • [38] Correlation of radiological parameters with functional outcomes post fixation with proximal humerus locking plates
    Mathur, Bhavya
    Suriyakumar, Sundar
    Manickam, Karthikeyan
    Sameer, Mohamed
    Harshvardhan, J. K. Giriraj
    INTERNATIONAL ORTHOPAEDICS, 2024, 48 (12) : 3207 - 3216
  • [39] A novel method of open reduction and internal fixation of a displaced manubrial fracture using distal clavicle locking plates
    Miller, Daniel
    Akhtar, M. Adeel
    Fergusson, Jonathan
    McVie, James L.
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2017, 25 (05) : 842 - 843
  • [40] A comparison of conventional compression plates and locking compression plates using cantilever bending in an ilial fracture model
    Bruce, C. W.
    Gibson, T. W. G.
    Runciman, R. J.
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2014, 27 (06) : 430 - 435