Are conventional reconstruction plates equivalent to precontoured locking plates for distal humerus fracture fixation? A biomechanics cadaver study

被引:30
|
作者
Koonce, Ryan C. [1 ]
Baldini, Todd H. [2 ]
Morgan, Steven J. [3 ]
机构
[1] Skagit Reg Clin, Mt Vernon, WA 98274 USA
[2] Univ Colorado, Sch Med, Dept Orthopaed Surg, Aurora, CO 80045 USA
[3] Swedish Med Ctr, MOTUS Orthopaed, Englewood, CO 80113 USA
关键词
Humerus fracture; Fixation; Locking plate; Biomechanics; Cadaver; PLATING SYSTEMS; PARALLEL;
D O I
10.1016/j.clinbiomech.2012.03.008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: The optimal plate type and configuration for distal humerus fracture fixation has yet to be defined. Available biomechanical studies show conflicting results. No existing studies compare conventional reconstruction plates to newer precontoured distal humerus locking plates in both parallel and perpendicular configurations. Methods: Three groups of humerus specimens were compared via biomechanical testing in a cadaver model simulating metaphyseal comminution. Group 1 consisted of conventional reconstruction plates in a perpendicular configuration. Group 2 used precontoured locking plates in a perpendicular configuration. Group 3 used precontoured locking plates in a parallel configuration. Each group was tested for stiffness in anterior bending, posterior bending, axial compression, and torsion. The specimens then underwent cyclic loading followed by single load to failure in posterior bending. Findings: There was no significant difference between the three groups for anterior bending, posterior bending, axial compression, or torsional stiffness. There was no significant difference in load to failure for any of the three groups. Screw loosening was significantly higher in Group 1 when compared to Groups 2 and 3 after cyclic loading. Interpretation: In the early postoperative period, less expensive perpendicular conventional reconstruction plate constructs provide similar stiffness and load to failure properties to newer precontoured locking plate systems regardless of plate configuration. (c) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:697 / 701
页数:5
相关论文
共 50 条
  • [1] A biomechanical evaluation of methods of distal humerus fracture fixation using locking compression plates versus conventional reconstruction plates
    Korner, J
    Diederichs, G
    Arzdorf, M
    Lill, H
    Josten, C
    Schneider, E
    Linke, B
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (05) : 286 - 293
  • [2] The Use of Precontoured Humeral Locking Plates in the Management of Displaced Proximal Humerus Fracture
    Ricchetti, Eric T.
    DeMola, Philip M.
    Roman, Don
    Abboud, Joseph A.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2009, 17 (09) : 582 - 590
  • [3] Locking versus non-locking plates in fixation of extra-articular distal humerus fracture: a randomized controlled study
    Galal, Sherif
    Mattar, Yasser
    Solyman, Alaa Mohy Eldin
    Ezzat, Mostafa
    INTERNATIONAL ORTHOPAEDICS, 2020, 44 (12) : 2761 - 2767
  • [4] Locking versus non-locking plates in fixation of extra-articular distal humerus fracture: a randomized controlled study
    Sherif Galal
    Yasser Mattar
    Alaa Mohy Eldin Solyman
    Mostafa Ezzat
    International Orthopaedics, 2020, 44 : 2761 - 2767
  • [5] Locking plates in distal humerus fractures: study of 43 patients
    Gupta, Rakesh Kumar
    Gupta, Vinay
    Marak, Dickey Richard
    CHINESE JOURNAL OF TRAUMATOLOGY, 2013, 16 (04) : 207 - 211
  • [6] Locking plates in distal humerus fractures:study of 43 patients
    Rakesh Kumar Gupta
    Vinay Gupta
    Dickey Richard Marak
    中华创伤杂志(英文版), 2013, (04) : 207 - 211
  • [7] Stiffness of Locking and Conventional Plates in Fixation of Distal Fibula Fractures; A Finite Element Study
    Patel, Bipin
    Gustafson, Peter A.
    Jastifer, James
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION 2010, VOL 2, 2012, : 439 - +
  • [8] Functional outcome of type 13 C2 distal humerus fractures treated with precontoured locking plates
    Gowtam, S. V.
    Gunaki, Ravindra B.
    FORMOSAN JOURNAL OF SURGERY, 2021, 54 (03) : 85 - 90
  • [9] Angular stable fixation of displaced distal-third clavicle fractures with superior precontoured locking plates
    Fleming, Mark A.
    Dachs, Robert
    Maqungo, Sithombo
    du Plessis, Jean-Pierre
    Vrettos, Basil C.
    Roche, Stephen J. L.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2015, 24 (05) : 700 - 704
  • [10] Evaluation of outcome of distal humerus fracture fixation by two-locked plates
    Haidarah, Abdul Fatah Abbas Mansoor
    WORLD FAMILY MEDICINE, 2022, 20 (02): : 19 - 26