Quantitative myocardial perfusion PET parametric imaging at the voxel-level

被引:13
|
作者
Mohy-ud-Din, Hassan [1 ,2 ,3 ]
Lodge, Martin A. [2 ]
Rahmim, Arman [1 ,2 ]
机构
[1] Johns Hopkins Univ, Dept Elect & Comp Engn, Baltimore, MD 21218 USA
[2] Johns Hopkins Univ, Dept Radiol & Radiol Sci, Baltimore, MD 21287 USA
[3] Yale Univ, Dept Diagnost Radiol, New Haven, CT 06520 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2015年 / 60卷 / 15期
关键词
myocardial perfusion; coronary flow reserve; cardiovascular diseases; positron emission tomography; parametric imaging; physiological clustering; robust parameter estimation; CORONARY-ARTERY-DISEASE; DYNAMIC PET; BLOOD-FLOW; RB-82; PET; RECONSTRUCTION STRATEGIES; QUANTIFICATION; SEGMENTATION; IMAGES; RISK; CHALLENGES;
D O I
10.1088/0031-9155/60/15/6013
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Quantitative myocardial perfusion (MP) PET has the potential to enhance detection of early stages of atherosclerosis or microvascular dysfunction, characterization of flow-limiting effects of coronary artery disease (CAD), and identification of balanced reduction of flow due to multivessel stenosis. We aim to enable quantitative MP-PET at the individual voxel level, which has the potential to allow enhanced visualization and quantification of myocardial blood flow (MBF) and flow reserve (MFR) as computed from uptake parametric images. This framework is especially challenging for the 82Rb radiotracer. The short half-life enables fast serial imaging and high patient throughput; yet, the acquired dynamic PET images suffer from high noise-levels introducing large variability in uptake parametric images and, therefore, in the estimates of MBF and MFR. Robust estimation requires substantial post-smoothing of noisy data, degrading valuable functional information of physiological and pathological importance. We present a feasible and robust approach to generate parametric images at the voxel-level that substantially reduces noise without significant loss of spatial resolution. The proposed methodology, denoted physiological clustering, makes use of the functional similarity of voxels to penalize deviation of voxel kinetics from physiological partners. The results were validated using extensive simulations (with transmural and non-transmural perfusion defects) and clinical studies. Compared to post-smoothing, physiological clustering depicted enhanced quantitative noise versus bias performance as well as superior recovery of perfusion defects (as quantified by CNR) with minimal increase in bias. Overall, parametric images obtained from the proposed methodology were robust in the presence of high-noise levels as manifested in the voxel time-activity-curves.
引用
收藏
页码:6013 / 6037
页数:25
相关论文
共 50 条
  • [1] Quantitative myocardial perfusion PET parametric imaging at the voxel-level
    Mohy-ud-Din, Hassan
    Lodge, Martin
    Rahmim, Arman
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03):
  • [2] Parametric Myocardial Perfusion PET Imaging using Physiological Clustering
    Mohy-ud-Din, Hassan
    Karakatsanis, Nikolaos A.
    Lodge, Martin A.
    Tang, Jing
    Rahmim, Arman
    [J]. MEDICAL IMAGING 2014: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2014, 9038
  • [3] Voxel-level comparison of arterial spin-labeled perfusion MRI and FDG-PET in Alzheimer disease
    Chen, Y.
    Wolk, D. A.
    Eddin, J. S. R.
    Korczykowski, M.
    Martinez, P. M.
    Pvlusiek, E. S.
    Newberg, A. B.
    Julin, P.
    Arnold, S. E.
    Greenberg, J. H.
    Detre, J. A.
    [J]. NEUROLOGY, 2011, 77 (22) : 1977 - 1985
  • [4] Voxel-level comparison of arterial spin-labeled perfusion magnetic resonance imaging in adolescents with internet gaming addiction
    Feng, Qi
    Chen, Xue
    Sun, Jinhua
    Zhou, Yan
    Sun, Yawen
    Ding, Weina
    Zhang, Yong
    Zhuang, Zhiguo
    Xu, Jianrong
    Du, Yasong
    [J]. BEHAVIORAL AND BRAIN FUNCTIONS, 2013, 9
  • [5] Myocardial perfusion imaging with PET
    Driessen, Roel S.
    Raijmakers, Pieter G.
    Stuijfzand, Wijnand J.
    Knaapen, Paul
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2017, 33 (07): : 1021 - 1031
  • [6] Myocardial perfusion imaging with PET
    Roel S. Driessen
    Pieter G. Raijmakers
    Wijnand J. Stuijfzand
    Paul Knaapen
    [J]. The International Journal of Cardiovascular Imaging, 2017, 33 : 1021 - 1031
  • [7] MYOCARDIAL PERFUSION IMAGING WITH PET
    SCHWAIGER, M
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (04): : 693 - 698
  • [8] Voxel-level comparison of arterial spin-labeled perfusion magnetic resonance imaging in adolescents with internet gaming addiction
    Qi Feng
    Xue Chen
    Jinhua Sun
    Yan Zhou
    Yawen Sun
    Weina Ding
    Yong Zhang
    Zhiguo Zhuang
    Jianrong Xu
    Yasong Du
    [J]. Behavioral and Brain Functions, 9
  • [9] EANM procedural guidelines for PET/CT quantitative myocardial perfusion imaging
    Roberto Sciagrà
    Mark Lubberink
    Fabien Hyafil
    Antti Saraste
    Riemer H. J. A. Slart
    Denis Agostini
    Carmela Nappi
    Panagiotis Georgoulias
    Jan Bucerius
    Christoph Rischpler
    Hein J. Verberne
    [J]. European Journal of Nuclear Medicine and Molecular Imaging, 2021, 48 : 1040 - 1069
  • [10] Sparsity Constrained Direct Parametric Reconstruction in Dynamic PET Myocardial Perfusion Imaging
    Yang, Bao
    Tang, Jing
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2019, 60