Quantitative myocardial perfusion PET parametric imaging at the voxel-level

被引:13
|
作者
Mohy-ud-Din, Hassan [1 ,2 ,3 ]
Lodge, Martin A. [2 ]
Rahmim, Arman [1 ,2 ]
机构
[1] Johns Hopkins Univ, Dept Elect & Comp Engn, Baltimore, MD 21218 USA
[2] Johns Hopkins Univ, Dept Radiol & Radiol Sci, Baltimore, MD 21287 USA
[3] Yale Univ, Dept Diagnost Radiol, New Haven, CT 06520 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2015年 / 60卷 / 15期
关键词
myocardial perfusion; coronary flow reserve; cardiovascular diseases; positron emission tomography; parametric imaging; physiological clustering; robust parameter estimation; CORONARY-ARTERY-DISEASE; DYNAMIC PET; BLOOD-FLOW; RB-82; PET; RECONSTRUCTION STRATEGIES; QUANTIFICATION; SEGMENTATION; IMAGES; RISK; CHALLENGES;
D O I
10.1088/0031-9155/60/15/6013
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Quantitative myocardial perfusion (MP) PET has the potential to enhance detection of early stages of atherosclerosis or microvascular dysfunction, characterization of flow-limiting effects of coronary artery disease (CAD), and identification of balanced reduction of flow due to multivessel stenosis. We aim to enable quantitative MP-PET at the individual voxel level, which has the potential to allow enhanced visualization and quantification of myocardial blood flow (MBF) and flow reserve (MFR) as computed from uptake parametric images. This framework is especially challenging for the 82Rb radiotracer. The short half-life enables fast serial imaging and high patient throughput; yet, the acquired dynamic PET images suffer from high noise-levels introducing large variability in uptake parametric images and, therefore, in the estimates of MBF and MFR. Robust estimation requires substantial post-smoothing of noisy data, degrading valuable functional information of physiological and pathological importance. We present a feasible and robust approach to generate parametric images at the voxel-level that substantially reduces noise without significant loss of spatial resolution. The proposed methodology, denoted physiological clustering, makes use of the functional similarity of voxels to penalize deviation of voxel kinetics from physiological partners. The results were validated using extensive simulations (with transmural and non-transmural perfusion defects) and clinical studies. Compared to post-smoothing, physiological clustering depicted enhanced quantitative noise versus bias performance as well as superior recovery of perfusion defects (as quantified by CNR) with minimal increase in bias. Overall, parametric images obtained from the proposed methodology were robust in the presence of high-noise levels as manifested in the voxel time-activity-curves.
引用
收藏
页码:6013 / 6037
页数:25
相关论文
共 50 条
  • [31] QCResUNet: Joint Subject-Level and Voxel-Level Prediction of Segmentation Quality
    Qiu, Peijie
    Chakrabarty, Satrajit
    Phuc Nguyen
    Ghosh, Soumyendu Sekhar
    Sotiras, Aristeidis
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION, MICCAI 2023, PT IV, 2023, 14223 : 173 - 182
  • [32] Voxel-Level Importance Maps for Interpretable Brain Age Estimation
    Bintsi, Kyriaki-Margarita
    Baltatzis, Vasileios
    Hammers, Alexander
    Rueckert, Daniel
    [J]. INTERPRETABILITY OF MACHINE INTELLIGENCE IN MEDICAL IMAGE COMPUTING, AND TOPOLOGICAL DATA ANALYSIS AND ITS APPLICATIONS FOR MEDICAL DATA, 2021, 12929 : 65 - 74
  • [33] THREE-DIMENSIONAL VOXEL-LEVEL CLASSIFICATION OF ULTRASOUND SCATTERING
    Tai, Haowei
    Dolui, Swapnil
    Khairalseed, Mawia
    Hoyt, Kenneth
    [J]. 2020 IEEE 17TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2020), 2020, : 1838 - 1841
  • [34] Low-dose dynamic cerebral perfusion CT reconstruction based on voxel-level TAC correction (VTC)
    Chen, Zixiang
    Zhang, Na
    Zhang, Qiyang
    Liang, Kaiyi
    Huang, Zhenxing
    Quan, Guotao
    Li, Xiang
    Liang, Dong
    Hu, Zhanli
    [J]. BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2023, 86
  • [35] mpact of SPECT Reconstruction Methods on Voxel-Level Radiopharmaceutical Dosimetry
    Stearns, Charles
    Ryden, Tobias
    Bernhardt, Peter
    Grudzinski, Joseph
    Wickre, Paul
    Bednarz, Bryan
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2022, 63
  • [36] A fast nonlinear method for parametric imaging of myocardial perfusion by dynamic 13N-ammonia PET
    Golish, SR
    Hove, JD
    Schelbert, HR
    Gambhir, SS
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (06) : 924 - 931
  • [37] Bias-variance tradeoff of indirect versus direct parametric reconstruction for PET myocardial perfusion imaging
    Petibon, Yoann
    El Fakhri, Georges
    Ouyang, Jinsong
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [38] Use of optimization transfer for enhanced direct 4D parametric imaging in myocardial perfusion PET
    Rahmim, Arman
    Tang, Jing
    Mohy-ud-Din, Hassan
    Ay, Mohammad
    Lodge, Martin
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [39] Detection of reperfusion using quantitative measurement of myocardial perfusion with PET Rb-82 imaging
    Ruddy, TD
    Dekemp, RA
    Dalipaj, MM
    Aung, MT
    Golanowski, LN
    Beanlands, RS
    [J]. CIRCULATION, 1997, 96 (08) : 3491 - 3491
  • [40] Ventilation CT: Voxel-level comparison with HP gas MRI
    Tahir, Bilal
    Marshall, Helen
    Hughes, Paul
    Stewart, Neil
    Horn, Felix
    Collier, Guilhem
    Norquay, Graham
    Hart, Kerry
    Swinscoe, James
    Hatton, Matthew
    Wild, Jim
    Ireland, Rob
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2016, 48