EANM procedural guidelines for PET/CT quantitative myocardial perfusion imaging

被引:0
|
作者
Roberto Sciagrà
Mark Lubberink
Fabien Hyafil
Antti Saraste
Riemer H. J. A. Slart
Denis Agostini
Carmela Nappi
Panagiotis Georgoulias
Jan Bucerius
Christoph Rischpler
Hein J. Verberne
机构
[1] University of Florence,Nuclear Medicine Unit, Department of Experimental and Clinical Biomedical Sciences “Mario Serio”
[2] Uppsala University,Radiology & Molecular Imaging, Department of Surgical Sciences
[3] Uppsala University Hospital,Medical Physics
[4] University of Paris,Department of Nuclear Medicine, DMU IMAGINA, APHP, Hôpital Européen Georges
[5] Université de Paris,Pompidou
[6] PARCC,Turku PET Centre, Turku University Hospital
[7] INSERM 690,Heart Center
[8] University of Turku,Department of Nuclear Medicine and Molecular Imaging
[9] Turku University Hospital,Faculty of Science and Technology Biomedical, Photonic Imaging
[10] University Medical Center Groningen,Department of Nuclear Medicine, CHU Cote de Nacre
[11] University of Twente,Department of Advanced Biomedical Sciences
[12] Normandy University,Department of Nuclear Medicine, Faculty of Medicine
[13] University Federico II,Department of Nuclear Medicine, University Medicine Göttingen
[14] University of Thessaly,Department of Nuclear Medicine, University Hospital Essen
[15] University Hospital of Larissa,Department of Radiology and Nuclear Medicine, Amsterdam UMC, location AMC
[16] Georg-August University Göttingen,undefined
[17] University of Duisburg-Essen,undefined
[18] University of Amsterdam,undefined
关键词
PET; Myocardial blood flow; Myocardial flow reserve; Quantitative imaging;
D O I
暂无
中图分类号
学科分类号
摘要
The use of cardiac PET, and in particular of quantitative myocardial perfusion PET, has been growing during the last years, because scanners are becoming widely available and because several studies have convincingly demonstrated the advantages of this imaging approach. Therefore, there is a need of determining the procedural modalities for performing high-quality studies and obtaining from this demanding technique the most in terms of both measurement reliability and clinical data. Although the field is rapidly evolving, with progresses in hardware and software, and the near perspective of new tracers, the EANM Cardiovascular Committee found it reasonable and useful to expose in an updated text the state of the art of quantitative myocardial perfusion PET, in order to establish an effective use of this modality and to help implementing it on a wider basis. Together with the many steps necessary for the correct execution of quantitative measurements, the importance of a multiparametric approach and of a comprehensive and clinically useful report have been stressed.
引用
收藏
页码:1040 / 1069
页数:29
相关论文
共 50 条
  • [1] EANM procedural guidelines for PET/CT quantitative myocardial perfusion imaging
    Sciagra, Roberto
    Lubberink, Mark
    Hyafil, Fabien
    Saraste, Antti
    Slart, Riemer H. J. A.
    Agostini, Denis
    Nappi, Carmela
    Georgoulias, Panagiotis
    Bucerius, Jan
    Rischpler, Christoph
    Verberne, Hein J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (04) : 1040 - 1069
  • [2] EANM procedural guidelines for radionuclide myocardial perfusion imaging with SPECT and SPECT/CT: 2015 revision
    Verberne, Hein J.
    Acampa, Wanda
    Anagnostopoulos, Constantinos
    Ballinger, Jim
    Bengel, Frank
    De Bondt, Pieter
    Buechel, Ronny R.
    Cuocolo, Alberto
    van Eck-Smit, Berthe L. F.
    Flotats, Albert
    Hacker, Marcus
    Hindorf, Cecilia
    Kaufmann, Philip A.
    Lindner, Oliver
    Ljungberg, Michael
    Lonsdale, Markus
    Manrique, Alain
    Minarik, David
    Scholte, Arthur J. H. A.
    Slart, Riemer H. J. A.
    Tragardh, Elin
    de Wit, Tim C.
    Hesse, Birger
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 (12) : 1929 - 1940
  • [3] EANM procedural guidelines for radionuclide myocardial perfusion imaging with SPECT and SPECT/CT: 2015 revision
    Hein J. Verberne
    Wanda Acampa
    Constantinos Anagnostopoulos
    Jim Ballinger
    Frank Bengel
    Pieter De Bondt
    Ronny R. Buechel
    Alberto Cuocolo
    Berthe L. F. van Eck-Smit
    Albert Flotats
    Marcus Hacker
    Cecilia Hindorf
    Philip A. Kaufmann
    Oliver Lindner
    Michael Ljungberg
    Markus Lonsdale
    Alain Manrique
    David Minarik
    Arthur J. H. A. Scholte
    Riemer H. J. A. Slart
    Elin Trägårdh
    Tim C. de Wit
    Birger Hesse
    European Journal of Nuclear Medicine and Molecular Imaging, 2015, 42 : 1929 - 1940
  • [4] EANM/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiology
    Hesse, B
    Tägil, K
    Cuocolo, A
    Anagnostopoulos, C
    Bardiés, M
    Bax, J
    Bengel, F
    Sokole, EB
    Davies, G
    Dondi, M
    Edenbrandt, L
    Franken, P
    Kjaer, A
    Knuuti, J
    Lassmann, M
    Ljungberg, M
    Marcassa, C
    Marie, PY
    McKiddie, F
    O'Connor, M
    Prvulovich, E
    Underwood, R
    van Eck-Smit, B
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 (07) : 855 - 897
  • [5] EANM/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiology
    B. Hesse
    K. Tägil
    A. Cuocolo
    C. Anagnostopoulos
    M. Bardiés
    J. Bax
    F. Bengel
    E. Busemann Sokole
    G. Davies
    M. Dondi
    L. Edenbrandt
    P. Franken
    A. Kjaer
    J. Knuuti
    M. Lassmann
    M. Ljungberg
    C. Marcassa
    P. Y. Marie
    F. McKiddie
    M. O’Connor
    E. Prvulovich
    R. Underwood
    B. van Eck-Smit
    European Journal of Nuclear Medicine and Molecular Imaging, 2005, 32 : 855 - 897
  • [6] European procedural guidelines for myocardial perfusion imaging, an EANM and ESC Joint Project
    Tägil, K
    Cuoculo, A
    Hesse, B
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S267 - S267
  • [7] EANM procedural guidelines for myocardial perfusion scintigraphy using cardiac-centered gamma cameras
    Hyafil, Fabien
    Gimelli, Alessia
    Slart, Riemer H. J. A.
    Georgoulias, Panagiotis
    Rischpler, Christoph
    Lubberink, Mark
    Sciagra, Roberto
    Bucerius, Jan
    Agostini, Denis
    Verberne, Hein J.
    EUROPEAN JOURNAL OF HYBRID IMAGING, 2019, 3 (01):
  • [8] EANM procedural guidelines for myocardial perfusion scintigraphy using cardiac-centered gamma cameras
    Fabien Hyafil
    Alessia Gimelli
    Riemer H. J. A. Slart
    Panagiotis Georgoulias
    Christoph Rischpler
    Mark Lubberink
    Roberto Sciagra
    Jan Bucerius
    Denis Agostini
    Hein J. Verberne
    European Journal of Hybrid Imaging, 3
  • [9] FDG PET and PET/CT: EANM procedure guidelines for tumour PET imaging: version 1.0
    Ronald Boellaard
    Mike J. O’Doherty
    Wolfgang A. Weber
    Felix M. Mottaghy
    Markus N. Lonsdale
    Sigrid G. Stroobants
    Wim J. G. Oyen
    Joerg Kotzerke
    Otto S. Hoekstra
    Jan Pruim
    Paul K. Marsden
    Klaus Tatsch
    Corneline J. Hoekstra
    Eric P. Visser
    Bertjan Arends
    Fred J. Verzijlbergen
    Josee M. Zijlstra
    Emile F. I. Comans
    Adriaan A. Lammertsma
    Anne M. Paans
    Antoon T. Willemsen
    Thomas Beyer
    Andreas Bockisch
    Cornelia Schaefer-Prokop
    Dominique Delbeke
    Richard P. Baum
    Arturo Chiti
    Bernd J. Krause
    European Journal of Nuclear Medicine and Molecular Imaging, 2010, 37 : 181 - 200
  • [10] FDG PET and PET/CT: EANM procedure guidelines for tumour PET imaging: version 1.0
    Boellaard, Ronald
    O'Doherty, Mike J.
    Weber, Wolfgang A.
    Mottaghy, Felix M.
    Lonsdale, Markus N.
    Stroobants, Sigrid G.
    Oyen, Wim J. G.
    Kotzerke, Joerg
    Hoekstra, Otto S.
    Pruim, Jan
    Marsden, Paul K.
    Tatsch, Klaus
    Hoekstra, Corneline J.
    Visser, Eric P.
    Arends, Bertjan
    Verzijlbergen, Fred J.
    Zijlstra, Josee M.
    Comans, Emile F. I.
    Lammertsma, Adriaan A.
    Paans, Anne M.
    Willemsen, Antoon T.
    Beyer, Thomas
    Bockisch, Andreas
    Schaefer-Prokop, Cornelia
    Delbeke, Dominique
    Baum, Richard P.
    Chiti, Arturo
    Krause, Bernd J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (01) : 181 - 200