摘要
In recent years high efforts have been devoted to enhance spatial and temporal resolutions of PET detectors. However, accurately combining these two main features is, in most of the cases, challenging. Typically, a compromise has to be made between the number of readout channels, scintillator type and size, and photosensors arrangement if aiming for a good system performance, while keeping a moderate cost. In this work, we have studied several detector configurations for PET based on a set of 8x8 Silicon Photomultiplier (SiPMs) of 3x3 mm(2) active area, and LYSO crystal arrays with different pixel sizes. An exhaustive evaluation in terms of spatial, energy and timing resolution was made for all detector configurations. In some cases, when using pixel sizes different than SiPM active area, a significant amount of scintillation light may spread among several SiPMs. Therefore, we made use of a calibration method considering the different SiPM timing contributions. Best Detector Time Resolution (DTR) of 156 ps FWHM was measured when using 3x3 mm(2) crystal pixels directly coupled to the 3x3 mm(2) SiPMs. However, when using 1.5 mm crystal pixels with the same photosensor array, although we could clearly resolve all crystal pixels, an average DTR of 250 ps FWHM was achieved. We also shed light in this work on the timing dependency of the crystal pixel and photosensor alignment.
引用
收藏
页数:8
相关论文
共 47 条
  • [21] Potential of Depth-of-Interaction-Based Detection Time Correction in Cherenkov Emitter Crystals for TOF-PET
    He, Xuzhi
    Trigila, Carlotta
    Arino-Estrada, Gerard
    Roncali, Emilie
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2023, 7 (03) : 233 - 240
  • [22] Depth-of-interaction study of a dual-readout detector based on TOFPET2 application-specific integrated circuit
    Li, Mohan
    Abbaszadeh, Shiva
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (17):
  • [23] An FPGA-Based 64-Channel Readout Electronics for High-Resolution TOF-PET Detectors
    Zhang, Xiang
    Wang, Yonggang
    Wang, Mingchen
    Kong, Xiaoguang
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2025, 9 (01) : 11 - 19
  • [24] Channel-based Energy Resolution of TOFPET2C-read PET Detectors
    Nadig, V.
    Schug, D.
    Radermacher, H.
    Weissler, B.
    Schulz, V.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S122 - S122
  • [25] Characterisation of a high granularity multi-channel prompt -ray detection system prototype for proton range verification based on the PETsys TOFPET2 ASIC
    Novgorodova, O.
    Glatte, A.
    Hentges, R.
    Koegler, T.
    Lutz, B.
    Roemer, K.
    Teichmann, T.
    Weinberger, D.
    Straessner, A.
    JOURNAL OF INSTRUMENTATION, 2024, 19 (02)
  • [26] Evaluation of Two SiPM Arrays for Depth-Encoding PET Detectors Based on Dual-Ended Readout
    Yang, Qian
    Wang, Xiaohui
    Kuang, Zhonghua
    Zhang, Chaoqun
    Yang, Yongfeng
    Du, Junwei
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2021, 5 (03) : 315 - 321
  • [27] An FPGA-Based Fast Linear Discharge Readout Scheme Enabling Simultaneous Time and Energy Measurements for TOF-PET Detectors
    Kong, Xiaoguang
    Wang, Yonggang
    Wang, Liwei
    Xiao, Yong
    Kuang, Jie
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2020, 4 (01) : 30 - 36
  • [28] Development and evaluation of an ultra-fast ASIC for future PET scanners using TOF-capable MPPC array detectors
    Ambe, T.
    Ikeda, H.
    Kataoka, J.
    Matsuda, H.
    Kato, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 771 : 66 - 73
  • [29] Evaluation of resistive-plate-chamber-based TOF-PET applied to in-beam particle therapy monitoring
    Torres-Espallardo, I.
    Diblen, F.
    Rohling, H.
    Solevi, P.
    Gillam, J.
    Watts, D.
    Espana, S.
    Vandenberghe, S.
    Fiedler, F.
    Rafecas, M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (09): : N187 - N208
  • [30] NEMA NU2-like performance evaluation of a helmet-type brain TOF-PET prototype
    Akamatsu, Go
    Yoshida, Eiji
    Tashima, Hideaki
    Iwao, Yuma
    Takahashi, Miwako
    Yamashita, Taichi
    Yamaya, Taiga
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60