In-depth evaluation of TOF-PET detectors based on crystal arrays and the TOFPET2 ASIC

被引:14
|
作者
Lamprou, Efthymios [1 ]
Sanchez, Filomeno [1 ]
Benlloch, Jose M. [1 ]
Gonzalez, Antonio J. [1 ]
机构
[1] Univ Politecn Valencia, CSIC, Ctr Mixto, Inst Instrumentac Imagen Mol I3M, Valencia 46022, Spain
基金
欧洲研究理事会;
关键词
TOF-PET; ASIC; Time walk; Crystal arrays; SiPM; Timing resolution; PS;
D O I
10.1016/j.nima.2020.164295
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In recent years high efforts have been devoted to enhance spatial and temporal resolutions of PET detectors. However, accurately combining these two main features is, in most of the cases, challenging. Typically, a compromise has to be made between the number of readout channels, scintillator type and size, and photosensors arrangement if aiming for a good system performance, while keeping a moderate cost. In this work, we have studied several detector configurations for PET based on a set of 8x8 Silicon Photomultiplier (SiPMs) of 3x3 mm(2) active area, and LYSO crystal arrays with different pixel sizes. An exhaustive evaluation in terms of spatial, energy and timing resolution was made for all detector configurations. In some cases, when using pixel sizes different than SiPM active area, a significant amount of scintillation light may spread among several SiPMs. Therefore, we made use of a calibration method considering the different SiPM timing contributions. Best Detector Time Resolution (DTR) of 156 ps FWHM was measured when using 3x3 mm(2) crystal pixels directly coupled to the 3x3 mm(2) SiPMs. However, when using 1.5 mm crystal pixels with the same photosensor array, although we could clearly resolve all crystal pixels, an average DTR of 250 ps FWHM was achieved. We also shed light in this work on the timing dependency of the crystal pixel and photosensor alignment.
引用
收藏
页数:8
相关论文
共 47 条
  • [11] Pilot tests of a PET detector using the TOF-PET ASIC based on monolithic crystals and SiPMs
    Aguilar, A.
    Gonzalez-Montoro, A.
    Gonzalez, A. J.
    Hernandez, L.
    Monzo, J. M.
    Bugalho, R.
    Ferramacho, L.
    Benlloch, J. M.
    JOURNAL OF INSTRUMENTATION, 2016, 11
  • [12] Time walk correction for TOF-PET detectors based on a monolithic scintillation crystal coupled to a photosensor array
    Vinke, R.
    Lohner, H.
    Schaart, D. R.
    van Dam, H. T.
    Seifert, S.
    Beekman, F. J.
    Dendooven, P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 621 (1-3): : 595 - 604
  • [13] Development of a Multi-Channel ASIC with Individual Energy and Timing Digitization for SiPM Detectors for TOF-PET Applications
    Chen, Yu
    Deng, Zhi
    Liu, Yinong
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [14] Monolithic-scintillator TOF-PET detectors based on digital silicon photomultipliers
    Schaart, Dennis
    Borghi, Giacomo
    Van Dam, Herman
    Van der Lei, Gerben
    Seifert, Stefan
    Tabacchini, Valerio
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [15] An FPGA-based Time Sampling Charge Measurement Method for TOF-PET Detectors
    Wu, Bo
    Wang, Yonggang
    Cao, Qiang
    Kuang, Jie
    Wang, Mingchen
    Zhou, Xiaoyu
    2019 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2019, : 399 - 403
  • [16] Development of TOF-PET detectors based on the Multi-Gap Resistive Plate Chambers
    Amaldi, U.
    Borghi, G.
    Bucciantonio, M.
    Kieffer, R.
    Samarati, J.
    Sauli, F.
    Watts, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 778 : 85 - 91
  • [17] The TT-PET project: a thin TOF-PET scanner based on fast novel silicon pixel detectors
    Bandi, Y.
    Benoit, M.
    Cadoux, F. R.
    Forshaw, D. C.
    Hanni, R.
    Hayakawa, D.
    Iacobucci, G.
    Michal, S.
    Miucci, A.
    Paolozzi, L.
    Ratib, O.
    Ripiccini, E.
    Tognina, C.
    Valerio, P.
    Weber, M.
    JOURNAL OF INSTRUMENTATION, 2018, 13
  • [18] Performance evaluation of a staggered three-layer DOI PET detector using a 1 mm LYSO pitch with PETsys TOFPET2 ASIC: comparison of HAMAMATSU and KETEK SiPMs
    Binder, Tim
    Kang, Han Gyu
    Nitta, Munetaka
    Schneider, Florian
    Yamaya, Taiga
    Parodi, Katia
    Wiest, Florian
    Thirolf, Peter G.
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (12):
  • [19] Time and Energy Resolving Time-over-Threshold ASIC for MPPC module in TOF-PET system (ToT-ASIC2)
    Orita, T.
    Uenomachi, M.
    Shimazoe, K.
    Ikeda, H.
    JOURNAL OF INSTRUMENTATION, 2023, 18 (09)
  • [20] Positron Emitter Depth Distribution in PMMA Irradiated With 130-MeV Protons Measured Using TOF-PET Detectors
    Nemallapudi, Mythra Varun
    Rahman, Atiq
    Chen, Augustine Ei-Fong
    Lee, Shih-Chang
    Lin, Chih-Hsun
    Chu, Ming-Lee
    Chou, Chen-Ying
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2022, 6 (03) : 345 - 354