Helical tomotherapy for the treatment of anal canal cancer: a dosimetric comparison with 3D conformal radiotherapy

被引:7
|
作者
Ugurluer, Gamze [1 ]
Ballerini, Giorgio [1 ]
Moeckli, Raphael [2 ]
Matzinger, Oscar [1 ]
Bourhis, Jean [1 ]
Ozsahin, Mahmut [1 ]
机构
[1] Univ Lausanne, Univ Hosp Ctr, Dept Radiat Oncol, Lausanne, Switzerland
[2] Univ Lausanne, Univ Hosp Ctr, Inst Radiat Phys, Lausanne, Switzerland
关键词
Anal canal cancer; 3D Conformal radiotherapy; Helical tomotherapy; MODULATED RADIATION-THERAPY; TRIAL ACT I; FOLLOW-UP; RTOG; 0529; CARCINOMA; IMRT; MITOMYCIN; CHEMORADIATION; FLUOROURACIL; CHEMOTHERAPY;
D O I
10.5301/tj.5000269
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Aims and Background: The standard treatment of anal canal cancer (ACC) is combined chemotherapy and radiation therapy (RT), which is complex because of the shape of the target volumes and the need to minimize the irradiation of normal pelvic structures. In this study we compared the dosimetric results of helical tomotherapy (HT) plans with traditional 3D conformal RT (3DRT) plans for the treatment of ACC. Methods and Study design: Twelve patients (median age 57 years, range 38-83; F/M 8/4) treated with HT and concurrent chemotherapy for locally advanced ACC were selected. All had histologically confirmed squamous-cell carcinoma. A clinical target volume including the tumor and pelvic and inguinal lymph nodes was treated with HT to a total dose of 36 Gy in 1.8-Gy daily fractions. Then a sequential boost of 23.4 Gy in 1.8-Gy daily fractions (total dose 59.4 Gy) was delivered to the tumor and involved nodes. For all 12 patients, 3DRT plans were generated for comparison. Treatment plans were evaluated by means of standard dose-volume histograms. Dose coverage of the planning target volumes (PTVs), homogeneity index (HI), and mean doses to organs at risk (OARs) were compared. Results: The coverage of PTV was comparable between the two treatment plans. HI was better in the HT vs. 3DRT plans (1.25 and 3.57, respectively; p<0.0001). HT plans resulted in better sparing of OARs (p<0.0001). Conclusions: HT showed superior target dose conformality and significant sparing of pelvic structures compared with 3DRT. Further investigation should determine if these dosimetric improvements will improve clinical outcomes regarding locoregional control, survival, and treatment-related acute and late morbidity.
引用
收藏
页码:268 / 272
页数:5
相关论文
共 50 条
  • [21] Dosimetric comparison of 3-dimensional conformal radiotherapy, volumetric modulated arc therapy, and helical tomotherapy for postoperative gastric cancer patients
    Onal, Cem
    Dolek, Yemliha
    Yildirim, Berna Akkus
    [J]. JAPANESE JOURNAL OF RADIOLOGY, 2018, 36 (01) : 30 - 39
  • [22] DOSIMETRIC COMPARISON OF CONVENTIONAL AND 3D CONFORMAL TREATMENT PLANS FOR PROSTATE CANCER
    Allahverdi, M.
    Vaezzadeh, S. A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S250 - S250
  • [23] ADJUVANT RADIOTHERAPY FOR GASTRIC CANCER: A DOSIMETRIC COMPARISON OF 3-DIMENSIONAL CONFORMAL RADIOTHERAPY, TOMOTHERAPY® AND CONVENTIONAL INTENSITY MODULATED RADIOTHERAPY TREATMENT PLANS
    Dahele, Max
    Skinner, Matthew
    Schultz, Brenda
    Cardoso, Marlene
    Bell, Chris
    Ung, Yee C.
    [J]. MEDICAL DOSIMETRY, 2010, 35 (02) : 115 - 121
  • [24] Comparison of RapidArc Volumetric Modulated Arc Therapy, Helical Tomotherapy, and 3D Conformal Radiotherapy for Pediatric Craniospinal Irradiation
    Patel, S.
    Warkentin, H.
    Powell, K.
    Syme, A.
    Warkentin, B.
    Fallone, G.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S591 - S591
  • [25] Dosimetric evaluation according to the location of hepatic tumor: Comparison of 3D-conformal radiotherapy, non-coplanar intensity modulated radiotherapy, and helical tomotherapy
    Lee, I.
    Seong, J.
    Kim, Y.
    Koom, W.
    Kim, J.
    Jeon, B.
    Kim, J.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S546 - S547
  • [26] Irradiation of cranio spinal Axis - helical Tomotherapy vs. 3D conformal Radiotherapy
    Habl, G.
    Sterzing, F.
    Uhl, M.
    Krause, S.
    Schubert, K.
    Debus, J.
    Herfarth, K.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2012, 188 : 81 - 81
  • [27] A RADIOTHERAPY PLANNING STUDY COMPARING HELICAL TOMOTHERAPY WITH CONFORMAL RADIOTHERAPY FOR THE TREATMENT OF NODE POSITIVE ADVANCED ANAL CARCINOMA
    Aslam, Shahzeena
    Wildschut, Karen
    Uponi, Sara
    Burnet, Neil
    Jephcott, Catherine
    Wilson, Charles
    [J]. ANNALS OF ONCOLOGY, 2012, 23 : 73 - 73
  • [28] TRUE 3D-DOSIMETRIC VERIFICATION OF STEREOTACTIC RADIOTHERAPY (SRT), IMRT AND HELICAL TOMOTHERAPY ? A COMPARISON
    Todorovic, M.
    Fischer, M.
    Albers, D.
    Cremers, F.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S395 - S395
  • [29] Dosimetric comparison of three-dimensional conformal radiotherapy, intensity modulated radiotherapy, and helical tomotherapy for lung stereotactic body radiotherapy
    Kinhikar, Rajesh Ashok
    Ghadi, Yogesh G.
    Sahoo, Priyadarshini
    Laskar, Sarbani Ghosh
    Deshpande, Deepak D.
    Shrivastava, Shyam K.
    Agarwal, Jaiprakash
    [J]. JOURNAL OF MEDICAL PHYSICS, 2015, 40 (04) : 190 - 197
  • [30] Comparison of the helical tomotherapy against the multileaf collimator-based intensity-modulated radiotherapy and 3D conformal radiation modalities in lung cancer radiotherapy
    Mavroidis, P.
    Shi, C.
    Plataniotis, G. A.
    Delichas, M. G.
    Costa Ferreira, B.
    Rodriguez, S.
    Lind, B. K.
    Papanikolaou, N.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2011, 84 (998): : 161 - 172