Helical tomotherapy for the treatment of anal canal cancer: a dosimetric comparison with 3D conformal radiotherapy

被引:7
|
作者
Ugurluer, Gamze [1 ]
Ballerini, Giorgio [1 ]
Moeckli, Raphael [2 ]
Matzinger, Oscar [1 ]
Bourhis, Jean [1 ]
Ozsahin, Mahmut [1 ]
机构
[1] Univ Lausanne, Univ Hosp Ctr, Dept Radiat Oncol, Lausanne, Switzerland
[2] Univ Lausanne, Univ Hosp Ctr, Inst Radiat Phys, Lausanne, Switzerland
关键词
Anal canal cancer; 3D Conformal radiotherapy; Helical tomotherapy; MODULATED RADIATION-THERAPY; TRIAL ACT I; FOLLOW-UP; RTOG; 0529; CARCINOMA; IMRT; MITOMYCIN; CHEMORADIATION; FLUOROURACIL; CHEMOTHERAPY;
D O I
10.5301/tj.5000269
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Aims and Background: The standard treatment of anal canal cancer (ACC) is combined chemotherapy and radiation therapy (RT), which is complex because of the shape of the target volumes and the need to minimize the irradiation of normal pelvic structures. In this study we compared the dosimetric results of helical tomotherapy (HT) plans with traditional 3D conformal RT (3DRT) plans for the treatment of ACC. Methods and Study design: Twelve patients (median age 57 years, range 38-83; F/M 8/4) treated with HT and concurrent chemotherapy for locally advanced ACC were selected. All had histologically confirmed squamous-cell carcinoma. A clinical target volume including the tumor and pelvic and inguinal lymph nodes was treated with HT to a total dose of 36 Gy in 1.8-Gy daily fractions. Then a sequential boost of 23.4 Gy in 1.8-Gy daily fractions (total dose 59.4 Gy) was delivered to the tumor and involved nodes. For all 12 patients, 3DRT plans were generated for comparison. Treatment plans were evaluated by means of standard dose-volume histograms. Dose coverage of the planning target volumes (PTVs), homogeneity index (HI), and mean doses to organs at risk (OARs) were compared. Results: The coverage of PTV was comparable between the two treatment plans. HI was better in the HT vs. 3DRT plans (1.25 and 3.57, respectively; p<0.0001). HT plans resulted in better sparing of OARs (p<0.0001). Conclusions: HT showed superior target dose conformality and significant sparing of pelvic structures compared with 3DRT. Further investigation should determine if these dosimetric improvements will improve clinical outcomes regarding locoregional control, survival, and treatment-related acute and late morbidity.
引用
收藏
页码:268 / 272
页数:5
相关论文
共 50 条
  • [41] Dosimetric comparison of Helical Tomotherapy and VMAT for endometrial cancer
    Dizmen, A.
    Yazici, O.
    Kocer, A. M.
    Kaplan, N.
    Ertan, F.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S791 - S792
  • [42] Dosimetric comparison of postoperative whole pelvic radiotherapy for endometrial cancer using three-dimensional conformal radiotherapy, intensity-modulated radiotherapy, and helical tomotherapy
    Yang, Ruijie
    Xu, Shouping
    Jiang, Weijuan
    Wang, Junjie
    Xie, Chuanbin
    [J]. ACTA ONCOLOGICA, 2010, 49 (02) : 230 - 236
  • [43] A comparison of supine intensity-modulated radiotherapy treatment with prone 3D conformal radiotherapy for rectal cancer: Preliminary results of dosimetric analysis
    Usiene, I.
    Andrade, R. S.
    Heron, D. E.
    McCoy, C.
    Mohney, M. M.
    Smith, R. P.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S296 - S297
  • [44] Treatment planning comparison between conformal radiotherapy and helical tomotherapy in case of stage IIINSCLC
    Cattaneo, G
    Dell'Oca, I
    Broggi, S
    Molinelli, S
    Muzio, ND
    Messa, C
    Fazio, F
    Calandrino, R
    [J]. RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S222 - S222
  • [45] A comparison of radiation treatment plans using IMRT with helical tomotherapy and 3D conformal radiotherapy for nasal natural killer/T-cell lymphoma
    Tomita, N.
    Kodaira, T.
    Tachibana, H.
    Nakamura, T.
    Nakahara, R.
    Inokuchi, H.
    Mizoguchi, N.
    Takada, A.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2009, 82 (981): : 756 - 763
  • [46] Dosimetric comparison of helical tomotherapy and stereotactic radiotherapy for single brain lesions
    Reinartz, G.
    Ernst, I
    Willich, N.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 : 35 - 35
  • [47] A dosimetric comparison of Helical Tomotherapy and VMAT in the treatment of high risk prostate cancer
    Lacornerie, T.
    Cavillon, F.
    Hardhuin, R.
    Compte, P.
    Reynaert, N.
    Lartigau, E. F.
    Pasquier, D.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S202 - S202
  • [48] Dosimetric study and in-vivo dose verification for conformal avoidance helical tomotherapy of anal adenocarcinoma
    Han, C.
    Chen, Y.
    Liu, A.
    Schultheiss, T.
    Wong, J.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2093 - 2093
  • [49] A comparison of dosimetric parameters between tomotherapy and three-dimensional conformal radiotherapy in rectal cancer
    Mina Yu
    Joo Hwan Lee
    Hong Seok Jang
    Dong Min Jeon
    Jae Suk Cheon
    Hyo Chun Lee
    Jong Hoon Lee
    [J]. Radiation Oncology, 8
  • [50] Is IMAT the ultimate evolution of conformal radiotherapy? Dosimetric comparison of helical tomotherapy and volumetric modulated arc therapy for oropharyngeal cancer in a planning study
    Vernat, Stephanie Servagi
    Ali, David
    Puyraveau, Marc
    Viard, Romain
    Lisbona, Albert
    Fenoglietto, Pascal
    Bedos, Ludovic
    Makovicka, Libor
    Giraud, Philippe
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (03): : 280 - 285