Modelling the Quench Tower in Flue Gas Cleaning of a Waste Fueled Power Plant

被引:0
|
作者
Wang, Bin [1 ,2 ]
Li, Hailong [1 ,2 ]
Yan, Jinying [3 ,4 ]
Thorin, Eva [1 ]
Schwede, Sebastian [1 ]
Zhu, Kai [2 ]
机构
[1] Malardalen Univ, Sch Business Soc & Engn, SE-72123 Vasteras, Sweden
[2] Tianjin Univ Commerce, Key Lab Refrigerat Technol Tianjin, Tianjin 300134, Peoples R China
[3] KTH Royal Inst Technol, Chem Engn, SE-10044 Stockholm, Sweden
[4] Vattenfall AB, R&D, SE-16992 Stockholm, Sweden
关键词
flue gas; quench; mathematic model; temperature of exit FG; water consumption; COMBUSTION;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
To control the emission of pollutants in the flue gas, a separated flue gas quench was added after flue gas desulfurization and before flue gas condensation. A mathematic model was developed to simulate the heat and mass transfer in the flue gas quench. The model was validated through the comparison with measured data. Based on this model, the impacts of inlet flue gas condition and injected recycling water flow rate on the water consumption of the quench and the temperature of exit flue gas (FG) were studied. The results show that the temperature of exit FG and water consumption increased with the increase of flow rate and moisture content of FG. The temperature of exit FG increased and the water consumption decreased with the increase of droplet water diameter. The temperature of exit FG decreased and the water consumption increased with the increase of water flow rate. In order to cooled and humidified the flue gas sufficiently, the droplet diameter should be limited to 1.2 mm and the water to FG flow rate ratio (L/G) higher than 2.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Detailed modelling of a flue-gas desulfurisation plant
    Gomez, Antonio
    Fueyo, Norberto
    Tomas, Alfredo
    COMPUTERS & CHEMICAL ENGINEERING, 2007, 31 (11) : 1419 - 1431
  • [32] Exergy and economic analysis of using the flue gas injection system of a combined cycle power plant into the Heller Tower to improve the power plant performance
    Jahangiri, A.
    Yahyaabadi, M. M.
    Sharif, A.
    JOURNAL OF CLEANER PRODUCTION, 2019, 233 : 695 - 710
  • [33] The effect on growth of Chlamydomonas reinhardtii of flue gas from a power plant based on waste combustion
    Leiv M Mortensen
    Hans R Gislerød
    AMB Express, 4
  • [34] Performance investigation of a counterflow packing tower for flue gas waste heat recovery
    Jiang, Yan
    Zhang, Huan
    Wang, Yaran
    You, Shijun
    Wu, Zhangxiang
    Song, Zixu
    APPLIED THERMAL ENGINEERING, 2021, 196
  • [35] The effect on growth of Chlamydomonas reinhardtii of flue gas from a power plant based on waste combustion
    Mortensen, Leiv M.
    Gislerod, Hans R.
    AMB EXPRESS, 2014, 4 : 1 - 9
  • [36] Possibilities for the Cleaning of Flue Gases in Planned Waste Burning Plant in Zagreb.
    Milanovic, Zlatko
    Energija, 1986, 35 (06): : 477 - 487
  • [37] Investigation and Evaluation of Flue Gas Pollutants Emission in Waste-to-Energy Plant with Flue Gas Recirculation
    Wang, Weishu
    Tian, Shujian
    Long, Jisheng
    Liu, Jun
    Ma, Qinhui
    Xu, Kai
    Zhang, Zhen
    ATMOSPHERE, 2022, 13 (07)
  • [38] Sinter plant waste gas cleaning - State of the art
    Hartig, W.
    Stedem, K. H.
    Lin, R.
    REVUE DE METALLURGIE-CAHIERS D INFORMATIONS TECHNIQUES, 2006, 103 (06): : 257 - 265
  • [39] Evaluation of a flue gas cleaning system of a circulating fluidized bed incineration power plant by the analysis of pollutant emissions
    Su, Xiaowen
    Zhang, Lin
    Xiao, Yuxin
    Sun, Mingming
    Gao, Xue
    Su, Jixin
    POWDER TECHNOLOGY, 2015, 286 : 9 - 15
  • [40] Flue Gas Composition and Treatment Potential of a Waste Incineration Plant
    Thabit, Qahtan
    Nassour, Abdallah
    Nelles, Michael
    APPLIED SCIENCES-BASEL, 2022, 12 (10):