The effect on growth of Chlamydomonas reinhardtii of flue gas from a power plant based on waste combustion

被引:8
|
作者
Mortensen, Leiv M. [1 ]
Gislerod, Hans R. [1 ]
机构
[1] Univ Life Sci, Dept Plant Sci, NO-1432 As, Norway
来源
AMB EXPRESS | 2014年 / 4卷
关键词
Carbon dioxide concentration; Chlamydomonas reinhardtii; Flue gas; Photosynthetic active radiation; CULTIVATION; CO2;
D O I
10.1186/s13568-014-0049-4
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Flue gases from a power plant based on waste combustion were tested as a carbon dioxide (CO2) source for growing Chlamydomonas reinhardtii. To achieve recognition as an environmentally friendly hydrogen production method, waste gases should be used to grow this hydrogen-producing microalgae. The algae were grown in undiluted flue gas containing 11.4 +/- 0.2% CO2 by volume, in diluted flue gas containing 6.7 +/- 0.1% or 2.5 +/- 0.0% CO2, and in pure liquid CO2 at a concentration of 2.7 +/- 0.2%. The NOx concentration was 45 +/- 16 mg m(-3), the SO2 concentration was 36 +/- 19 mg m(-3), the HCl concentration 4.1 +/- 1.0 mg m(-3) and the O-2 concentration 7.9 +/- 0.2% in the undiluted flue gas. Undiluted flue gas reduced the dry weight production by around 20-25% when grown at a photon flux density (PFD) of 300 mu mol m(-2) s(-1) artificial light and at 24 or 33 degrees C, compared with the other treatments. A less negative effect was found at the highest flue gas concentration when the algae were grown at 75 mu mol m(-2) s(-1) PFD. Growing the algae outdoors at a day length of 12.5 h and a temperature of around 24 degrees C, the dry weight production was higher (about 15%) in the 2.6% CO2 flue gas treatment compared with all other treatments. Reducing the light level by 30% through shading did not affect the dry weight production. Calculated on aerial basis the productivity reached approximately 70 g m(-2) day(-1) in the 300 mu mol m(-2) s(-1) PFD treatment (corresponding to 25 mol m(-2) day(-1)) and approximately 17 g m(-2) day(-1) in the 75 mu mol m(-2) s(-1) PFD treatment (corresponding to 6.5 mol m(-2) day(-1)). The outdoor production reached around 14 g m(-2) day(-1). It was concluded that the negative effect of the undiluted flue gas was attributable to the high CO2 concentration and not to the other pollutants.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
  • [1] The effect on growth of Chlamydomonas reinhardtii of flue gas from a power plant based on waste combustion
    Leiv M Mortensen
    Hans R Gislerød
    AMB Express, 4
  • [2] Effect of Mercury on the Growth of Chlamydomonas reinhardtii
    C. Weiss-Magasic
    B. Lustigman
    L. H. Lee
    Bulletin of Environmental Contamination and Toxicology, 1997, 59 : 828 - 833
  • [3] Effect of mercury on the growth of Chlamydomonas reinhardtii
    WeissMagasic, C
    Lustigman, B
    Lee, LH
    BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 1997, 59 (05) : 828 - 833
  • [4] Coal power plant flue gas waste heat and water recovery
    Wang, Dexin
    Bao, Ainan
    Kunc, Walter
    Liss, William
    APPLIED ENERGY, 2012, 91 (01) : 341 - 348
  • [5] Effect of selenate on growth and photosynthesis of Chlamydomonas reinhardtii
    Geoffroy, Laure
    Gilbin, Rodolphe
    Simon, Olivier
    Floriani, Magali
    Adam, Christelle
    Pradines, Catherine
    Cournac, Laurent
    Garnier-Laplace, Jacqueline
    AQUATIC TOXICOLOGY, 2007, 83 (02) : 149 - 158
  • [6] The growth of Chlamydomonas reinhardtii as influenced by high CO2 and low O2 in flue gas from a silicomanganese smelter
    Mortensen, Leiv M.
    Gislerod, Hans R.
    JOURNAL OF APPLIED PHYCOLOGY, 2015, 27 (02) : 633 - 638
  • [7] The growth of Chlamydomonas reinhardtii as influenced by high CO2 and low O2 in flue gas from a silicomanganese smelter
    Leiv M. Mortensen
    Hans R. Gislerød
    Journal of Applied Phycology, 2015, 27 : 633 - 638
  • [8] Effect of low-nitrogen combustion system with flue gas circulation technology on the performance of NOx emission in waste-to-energy power plant
    Zhang, Peng
    Shao, Yimin
    Niu, Juntian
    Zeng, Xianqiong
    Zheng, Xueyan
    Wu, Chonglu
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2022, 175
  • [9] Numerical study on an original oxy-fuel combustion power plant with efficient utilization of flue gas waste heat
    Liang, Ying
    Cai, Lei
    Guan, Yanwen
    Liu, Wenbin
    Xiang, Yanlei
    Li, Juan
    He, Tianzhi
    ENERGY, 2020, 193 : 1049 - 1062
  • [10] Carbon dioxide from power plant flue gas
    Martin, JW
    Killeffer, DH
    INDUSTRIAL AND ENGINEERING CHEMISTRY, 1937, 29 : 632 - 636