The effect on growth of Chlamydomonas reinhardtii of flue gas from a power plant based on waste combustion

被引:8
|
作者
Mortensen, Leiv M. [1 ]
Gislerod, Hans R. [1 ]
机构
[1] Univ Life Sci, Dept Plant Sci, NO-1432 As, Norway
来源
AMB EXPRESS | 2014年 / 4卷
关键词
Carbon dioxide concentration; Chlamydomonas reinhardtii; Flue gas; Photosynthetic active radiation; CULTIVATION; CO2;
D O I
10.1186/s13568-014-0049-4
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Flue gases from a power plant based on waste combustion were tested as a carbon dioxide (CO2) source for growing Chlamydomonas reinhardtii. To achieve recognition as an environmentally friendly hydrogen production method, waste gases should be used to grow this hydrogen-producing microalgae. The algae were grown in undiluted flue gas containing 11.4 +/- 0.2% CO2 by volume, in diluted flue gas containing 6.7 +/- 0.1% or 2.5 +/- 0.0% CO2, and in pure liquid CO2 at a concentration of 2.7 +/- 0.2%. The NOx concentration was 45 +/- 16 mg m(-3), the SO2 concentration was 36 +/- 19 mg m(-3), the HCl concentration 4.1 +/- 1.0 mg m(-3) and the O-2 concentration 7.9 +/- 0.2% in the undiluted flue gas. Undiluted flue gas reduced the dry weight production by around 20-25% when grown at a photon flux density (PFD) of 300 mu mol m(-2) s(-1) artificial light and at 24 or 33 degrees C, compared with the other treatments. A less negative effect was found at the highest flue gas concentration when the algae were grown at 75 mu mol m(-2) s(-1) PFD. Growing the algae outdoors at a day length of 12.5 h and a temperature of around 24 degrees C, the dry weight production was higher (about 15%) in the 2.6% CO2 flue gas treatment compared with all other treatments. Reducing the light level by 30% through shading did not affect the dry weight production. Calculated on aerial basis the productivity reached approximately 70 g m(-2) day(-1) in the 300 mu mol m(-2) s(-1) PFD treatment (corresponding to 25 mol m(-2) day(-1)) and approximately 17 g m(-2) day(-1) in the 75 mu mol m(-2) s(-1) PFD treatment (corresponding to 6.5 mol m(-2) day(-1)). The outdoor production reached around 14 g m(-2) day(-1). It was concluded that the negative effect of the undiluted flue gas was attributable to the high CO2 concentration and not to the other pollutants.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
  • [21] Flue Gas Cleaning Systems for Waste Incineration Plant
    A. Yu. Val'dberg
    V. I. Lazarev
    T. N. Kuzina
    Chemical and Petroleum Engineering, 2003, 39 (9-10) : 553 - 556
  • [22] Effect of glucose on cell growth and hydrogen production by chlamydomonas reinhardtii
    Jia, Li-Na
    Zhang, Xu
    Tan, Tian-Wei
    Beijing Huagong Daxue Xuebao (Ziran Kexueban)/Journal of Beijing University of Chemical Technology (Natural Science Edition), 2006, 33 (06): : 31 - 33
  • [23] THE EFFECTS OF FLUE-GAS FROM THE COMBUSTION OF WASTE OIL ONTO THE ACTIVITY OF CHOLINESTERASE
    BALIZS, G
    GYOCSI, L
    CHEMOSPHERE, 1983, 12 (7-8) : 975 - 980
  • [24] Modeling and Simulation for Post-Combustion Carbon Dioxide Capture from Power Plant Flue Gas with Economic Analysis
    Gupta, Nupur
    Mondal, Arijit
    Das, Bisweswar
    Deogam, Binay
    Barma, Sanjib
    Mandal, Bishnupada
    SEPARATION SCIENCE AND TECHNOLOGY, 2015, 50 (13) : 1952 - 1963
  • [25] An investigation of an oxygen-enriched combustion of municipal solid waste on flue gas emission and combustion performance at a 8 MWth waste-to-energy plant
    Ma, Chen
    Li, Bo
    Chen, Dongmei
    Weng, Terrence
    Ma, Wenchao
    Lin, Fawei
    Chen, Guanyi
    WASTE MANAGEMENT, 2019, 96 : 47 - 56
  • [26] Recovery and energy use of flue gas from a coal power plant
    Szulc, Piotr (piotr.szulc@pwr.edu.pl), 1600, Warsaw University of Technology (97):
  • [27] Emissions of batch combustion of waste tire chips:: The hot flue-gas filtering effect
    Caponero, J
    Tenório, JAS
    Levendis, YA
    Carlson, JB
    ENERGY & FUELS, 2004, 18 (01) : 102 - 115
  • [28] New particle formation in the fresh flue-gas plume from a coal-fired power plant: effect of flue-gas cleaning
    Myllari, Fanni
    Asmi, Eija
    Anttila, Tatu
    Saukko, Erkka
    Vakkari, Ville
    Pirjola, Liisa
    Hillamo, Risto
    Laurila, Tuomas
    Hayrinen, Anna
    Rautiainen, Jani
    Lihavainen, Heikki
    O'Connor, Ewan
    Niemela, Ville
    Keskinen, Jorma
    Dal Maso, Miikka
    Ronkko, Topi
    ATMOSPHERIC CHEMISTRY AND PHYSICS, 2016, 16 (11) : 7485 - 7496
  • [29] Application of a low pressure economizer for waste heat recovery from the exhaust flue gas in a 600 MW power plant
    Wang, Chaojun
    He, Boshu
    Sun, Shaoyang
    Wu, Ying
    Yan, Na
    Yan, Linbo
    Pei, Xiaohui
    ENERGY, 2012, 48 (01) : 196 - 202
  • [30] Effect of flue gas constituents on boiler tube failure of a captive power plant
    Ghosh, M.
    ENGINEERING FAILURE ANALYSIS, 2023, 151