Modelling the Quench Tower in Flue Gas Cleaning of a Waste Fueled Power Plant

被引:0
|
作者
Wang, Bin [1 ,2 ]
Li, Hailong [1 ,2 ]
Yan, Jinying [3 ,4 ]
Thorin, Eva [1 ]
Schwede, Sebastian [1 ]
Zhu, Kai [2 ]
机构
[1] Malardalen Univ, Sch Business Soc & Engn, SE-72123 Vasteras, Sweden
[2] Tianjin Univ Commerce, Key Lab Refrigerat Technol Tianjin, Tianjin 300134, Peoples R China
[3] KTH Royal Inst Technol, Chem Engn, SE-10044 Stockholm, Sweden
[4] Vattenfall AB, R&D, SE-16992 Stockholm, Sweden
关键词
flue gas; quench; mathematic model; temperature of exit FG; water consumption; COMBUSTION;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
To control the emission of pollutants in the flue gas, a separated flue gas quench was added after flue gas desulfurization and before flue gas condensation. A mathematic model was developed to simulate the heat and mass transfer in the flue gas quench. The model was validated through the comparison with measured data. Based on this model, the impacts of inlet flue gas condition and injected recycling water flow rate on the water consumption of the quench and the temperature of exit flue gas (FG) were studied. The results show that the temperature of exit FG and water consumption increased with the increase of flow rate and moisture content of FG. The temperature of exit FG increased and the water consumption decreased with the increase of droplet water diameter. The temperature of exit FG decreased and the water consumption increased with the increase of water flow rate. In order to cooled and humidified the flue gas sufficiently, the droplet diameter should be limited to 1.2 mm and the water to FG flow rate ratio (L/G) higher than 2.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Carbon dioxide from power plant flue gas
    Martin, JW
    Killeffer, DH
    INDUSTRIAL AND ENGINEERING CHEMISTRY, 1937, 29 : 632 - 636
  • [42] Emission reduction optimization of multiple flue gas pollutants in Municipal solid waste incineration power plant
    Wang, Tianzheng
    Tang, Jian
    Aljerf, Loai
    Qiao, Junfei
    Alajlani, Muaaz
    FUEL, 2025, 381
  • [43] Modelling of wet limestone-gypsum flue gas desulfurization system in spray tower
    Zhu, Jie
    Wu, Zhen-Yuan
    Ye, Shi-Chao
    Zheng, Yi-Jun
    Yang, Yun-Feng
    Bai, Jie
    Gao Xiao Hua Xue Gong Cheng Xue Bao/Journal of Chemical Engineering of Chinese Universities, 2015, 29 (01): : 220 - 225
  • [44] A small scale biomass fueled gas turbine power plant
    Craig, JD
    Purvis, CR
    BIOMASS FOR ENERGY AND INDUSTRY, 1998, : 287 - 290
  • [45] DEVELOPMENT OF FLUE-GAS CLEANING TECHNOLOGY AT THERMAL POWER-STATIONS
    KROPP, LI
    CHEKANOV, GS
    KHODAKOV, YS
    SHMIGOL, II
    THERMAL ENGINEERING, 1991, 38 (06) : 331 - 335
  • [46] INCINERATION PLANT WITH FLUE-GAS SCRUBBERS FOR DISPOSAL OF CHEMICAL WASTE
    FABIAN, HW
    REHER, P
    SCHON, M
    CHEMIE INGENIEUR TECHNIK, 1978, 50 (11) : 823 - 831
  • [47] Balances of contaminants in flue gas from municipal waste incineration plant
    Jecha, David
    Bebar, Ladislav
    Stehlik, Petr
    PRES 2012: 15TH INTERNATIONAL CONFERENCE ON PROCESS INTEGRATION, MODELLING AND OPTIMISATION FOR ENERGY SAVING AND POLLUTION REDUCTION, 2012, 29 : 1057 - 1062
  • [48] A method to valuate the effect of the deposition of acidifying pollutants on soil demonstrated at a power plant with flue gas discharge via cooling tower
    Braun, P
    Thon, H
    GEFAHRSTOFFE REINHALTUNG DER LUFT, 1997, 57 (05): : 207 - 214
  • [49] Acidity of rainfall samples in close vicinity of coal-fired power plant with wet cooling tower with flue gas injection
    Katarzyna Korszun-Klak
    Stanislaw Hlawiczka
    Rafal Kobylecki
    Environmental Monitoring and Assessment, 2021, 193
  • [50] Acidity of rainfall samples in close vicinity of coal-fired power plant with wet cooling tower with flue gas injection
    Korszun-Klak, Katarzyna
    Hlawiczka, Stanislaw
    Kobylecki, Rafal
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2021, 193 (10)