Reproducibility of normalized apparent diffusion coefficient measurements on 3.0-T diffusion-weighted imaging of normal pancreas in a healthy population

被引:8
|
作者
Ding, Xun [1 ]
Xu, Haibo [1 ]
Zhou, Jun [1 ]
Xu, Jia [1 ]
Mei, Hao [1 ]
Long, Qingyun [1 ]
Wang, Yaxun [1 ]
机构
[1] Wuhan Univ, Dept Med Imaging, Zhongnan Hosp, Wuhan 430071, Hubei, Peoples R China
关键词
normalized apparent diffusion coefficient; pancreas; reproducibility; CYSTIC-FIBROSIS; MRI; LESIONS; VALUES; MASS;
D O I
10.1097/MD.0000000000015104
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To prospectively compare the reproducibility of normal pancreas-normalized apparent diffusion coefficient (ADC) measurements for the normal pancreas and mean normalized ADCs at different pancreas anatomic locations. In total, 22 healthy volunteers underwent pancreatic 3.0-T magnetic resonance (MR) imaging, including axial diffusion-weighted (DW) imaging with 3 b values used (0, 400, and 800s/mm(2)) and with the respiratory-triggered (RT) technique. The mean ADCs from 3 regions of interest (ROIs) in 5 anatomic locations (head [H], body [B], and tail [T] of pancreas and spleen [S] and erector spinae muscles [M]) were calculated. The pancreas-normalized ADC was defined as the ratio of the ADC for the pancreas to the ADC for the spleen or erector spinae muscle. Reproducibility of ADCs and normalized ADCs was assessed by the Bland-Altman method. The ADC and normalized ADC data were analyzed by repeated-measures ANOVA. Mean ADC and normalized ADC values did not differ (P >. 05) with repeated measurements at the different pancreas anatomic locations. Reproducibility of pancreas-normalized ADC measurements in each of the 3 pancreatic anatomic locations was better with the erector spinae muscle rather than the spleen used as a reference. Mean ADC and normalized ADC values significantly differed between the 3 pancreatic segments (H: 1.36 x 10(-3) mm(2)/s, B: 1.38 x 10(-3) mm(2)/s, T: 1.25 x 10(-3) mm(2)/s, P=.022; H/S: 1.75, B/S: 1.78, T/S: 1.59, P=.009; H/M: 0.91, B/M: 0.95, T/M: 0.85, P=.008). Mean ADC values and normalized ADC values showed a trend to decrease from the pancreatic head to tail. Our preliminary results suggest that normalized ADC measurements for the pancreas show good intra-and interobserver reproducibility, the erector spinae muscle is a better choice than the spleen for calculating normalized ADC values for the pancreas, and the normalized ADC values are lower for the pancreatic tail than other pancreatic segments.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] The effect of susceptibility of gadolinium contrast media on diffusion-weighted imaging and the apparent diffusion coefficient
    Ogura, Akio
    Hayakawa, Katsumi
    Miyati, Tosiaki
    Maeda, Fumie
    ACADEMIC RADIOLOGY, 2008, 15 (07) : 867 - 872
  • [42] Diagnosis of Liver Fibrosis and Cirrhosis With Diffusion-Weighted Imaging: Value of Normalized Apparent Diffusion Coefficient Using the Spleen as Reference Organ
    Do, Richard K. G.
    Chandanara, Hersh
    Felker, Ely
    Hajdu, Cristina H.
    Babb, James S.
    Kim, Danny
    Taouli, Bachir
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (03) : 671 - 676
  • [43] Usefulness of diffusion-weighted imaging and the apparent diffusion coefficient in the assessment of head and neck tumors
    Maeda, Masayuki
    Maier, Stephan E.
    JOURNAL OF NEURORADIOLOGY, 2008, 35 (02) : 71 - 78
  • [44] Coronal Diffusion-weighted Magnetic Resonance Imaging of the Kidney: Agreement with Axial Diffusion-weighted Magnetic Imaging in Terms of Apparent Diffusion Coefficient Values
    Wang, Hai-Yi
    Wang, Jia
    Tang, Ye-Huan
    Ye, Hui-Yi
    Ma, Lin
    CHINESE MEDICAL JOURNAL, 2015, 128 (04) : 499 - 503
  • [45] Diffusion-Weighted Imaging of the Abdomen: Correction for Gradient Nonlinearity Bias in Apparent Diffusion Coefficient
    Wang, Jian
    Ma, Chao
    Yang, Panpan
    Wang, Zhen
    Chen, Yufei
    Bian, Yun
    Shao, Chengwei
    Lu, Jianping
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2023, 58 (01) : 223 - 231
  • [46] Evaluation of Cervical Myelopathy Using Apparent Diffusion Coefficient Measured by Diffusion-Weighted Imaging
    Sato, T.
    Horikoshi, T.
    Watanabe, A.
    Uchida, M.
    Ishigame, K.
    Araki, T.
    Kinouchi, H.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (02) : 388 - 392
  • [47] Rhabdomyosarcoma Metastasis to the Breast: Appearance on Diffusion-Weighted Imaging and Apparent Diffusion Coefficient Sequences
    Antony, Chermaine Deepa
    Rahmat, Kartini
    Vijayananthan, Anushya
    Pailoor, Jayalakshmi
    IRANIAN JOURNAL OF RADIOLOGY, 2017, 14 (01)
  • [48] The role of diffusion-weighted imaging and the apparent diffusion coefficient (ADC) values for breast tumors
    Park, Mi Jung
    Cha, Eun Suk
    Kang, Bong Joo
    Ihn, Yon Kwon
    Baik, Jun Hyun
    KOREAN JOURNAL OF RADIOLOGY, 2007, 8 (05) : 390 - 396
  • [49] Diffusion-weighted MR imaging in primary brain lymphoma: Evaluation of apparent diffusion coefficient
    Ukisu, R
    Kushihashi, T
    Gokan, T
    Fujisawa, H
    Tanno, K
    Munechika, H
    RADIOLOGY, 2000, 217 : 186 - 186
  • [50] Significance of diffusion-weighted imaging and apparent diffusion coefficient maps for the evaluation of pyogenic ventriculitis
    Hong, Jae Taek
    Son, Byung Chul
    Sung, Jae Hoon
    Kim, Il Sub
    Yang, Seung Ho
    Lee, Sang Won
    Park, Chun Kun
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2008, 110 (02) : 137 - 144