Reproducibility of normalized apparent diffusion coefficient measurements on 3.0-T diffusion-weighted imaging of normal pancreas in a healthy population

被引:8
|
作者
Ding, Xun [1 ]
Xu, Haibo [1 ]
Zhou, Jun [1 ]
Xu, Jia [1 ]
Mei, Hao [1 ]
Long, Qingyun [1 ]
Wang, Yaxun [1 ]
机构
[1] Wuhan Univ, Dept Med Imaging, Zhongnan Hosp, Wuhan 430071, Hubei, Peoples R China
关键词
normalized apparent diffusion coefficient; pancreas; reproducibility; CYSTIC-FIBROSIS; MRI; LESIONS; VALUES; MASS;
D O I
10.1097/MD.0000000000015104
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To prospectively compare the reproducibility of normal pancreas-normalized apparent diffusion coefficient (ADC) measurements for the normal pancreas and mean normalized ADCs at different pancreas anatomic locations. In total, 22 healthy volunteers underwent pancreatic 3.0-T magnetic resonance (MR) imaging, including axial diffusion-weighted (DW) imaging with 3 b values used (0, 400, and 800s/mm(2)) and with the respiratory-triggered (RT) technique. The mean ADCs from 3 regions of interest (ROIs) in 5 anatomic locations (head [H], body [B], and tail [T] of pancreas and spleen [S] and erector spinae muscles [M]) were calculated. The pancreas-normalized ADC was defined as the ratio of the ADC for the pancreas to the ADC for the spleen or erector spinae muscle. Reproducibility of ADCs and normalized ADCs was assessed by the Bland-Altman method. The ADC and normalized ADC data were analyzed by repeated-measures ANOVA. Mean ADC and normalized ADC values did not differ (P >. 05) with repeated measurements at the different pancreas anatomic locations. Reproducibility of pancreas-normalized ADC measurements in each of the 3 pancreatic anatomic locations was better with the erector spinae muscle rather than the spleen used as a reference. Mean ADC and normalized ADC values significantly differed between the 3 pancreatic segments (H: 1.36 x 10(-3) mm(2)/s, B: 1.38 x 10(-3) mm(2)/s, T: 1.25 x 10(-3) mm(2)/s, P=.022; H/S: 1.75, B/S: 1.78, T/S: 1.59, P=.009; H/M: 0.91, B/M: 0.95, T/M: 0.85, P=.008). Mean ADC values and normalized ADC values showed a trend to decrease from the pancreatic head to tail. Our preliminary results suggest that normalized ADC measurements for the pancreas show good intra-and interobserver reproducibility, the erector spinae muscle is a better choice than the spleen for calculating normalized ADC values for the pancreas, and the normalized ADC values are lower for the pancreatic tail than other pancreatic segments.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Diffusion-Weighted MR Imaging in Placental Insufficiency: Erroneous Units and Inaccurate Apparent Diffusion Coefficient Measurements
    Tebache, Malek
    Passoglou, Vassiliki
    Tebache, Linda
    Collignon, Laurent
    RADIOLOGY, 2011, 260 (01) : 303 - 303
  • [22] Diffusion-weighted magnetic resonance imaging of the normal endometrium: temporal and spatial variations of the apparent diffusion coefficient
    Fornasa, Francesca
    Montemezzi, Stefania
    ACTA RADIOLOGICA, 2012, 53 (05) : 586 - 590
  • [23] Evaluation of Treatment Response of Chemoembolization in Hepatocellular Carcinoma with Diffusion-Weighted Imaging on 3.0-T MR Imaging
    Sahin, Hilal
    Harman, Mustafa
    Cinar, Celal
    Bozkaya, Halil
    Parildar, Mustafa
    Elmas, Nevra
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2012, 23 (02) : 241 - 247
  • [24] Apparent diffusion coefficient measurements with diffusion-weighted imaging for differential diagnosis of soft-tissue tumor
    Zou, Yu
    Wang, Qi-Dong
    Zong, Min
    Zou, Yue-Fen
    Shi, Hai-Bin
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2016, 12 (02) : 864 - 870
  • [25] MR-Diffusion Weighted Imaging of Healthy Liver Parenchyma: Repeatability and Reproducibility of Apparent Diffusion Coefficient Measurement
    Colagrande, Stefano
    Pasquinelli, Filippo
    Mazzoni, Lorenzo Nicola
    Belli, Giacomo
    Virgili, Gianni
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (04) : 912 - 920
  • [26] Diffusion-weighted imaging with calculated apparent diffusion coefficient in intracranial hemorrhagic lesions
    Dorenbeck, U
    Schlaier, J
    Bretschneider, T
    Schuierer, G
    Feuerbach, S
    CLINICAL IMAGING, 2005, 29 (02) : 86 - 93
  • [27] Apparent Diffusion Coefficients of Normal Uterus in Premenopausal Women With 3.0-T Magnetic Resonance Imaging
    Kuang, Fei
    Ren, Jing
    Huan, Yi
    Chen, Ziqian
    Zhong, Qun
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2012, 36 (01) : 54 - 59
  • [28] Diffusion-weighted imaging of the pancreas
    Gruenberg, K.
    Grenacher, L.
    Klauss, M.
    RADIOLOGE, 2011, 51 (03): : 186 - +
  • [29] Magnetic resonance diffusion-weighted imaging: reproducibility of regional apparent diffusion coefficients forthe normal fetal brain
    Boyer, A. C.
    Goncalves, L. F.
    Lee, W.
    Shetty, A.
    Holman, A.
    Yeo, L.
    Romero, R.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2013, 41 (02) : 190 - 197
  • [30] Evaluation of Apparent Diffusion Coefficient Repeatability and Reproducibility for Preclinical MRIs Using Standardized Procedures and a Diffusion-Weighted Imaging Phantom
    Malyarenko, Dariya
    Amouzandeh, Ghoncheh
    Pickup, Stephen
    Zhou, Rong
    Manning, Henry Charles
    Gammon, Seth T.
    Shoghi, Kooresh I.
    Quirk, James D.
    Sriram, Renuka
    Larson, Peder
    Lewis, Michael T.
    Pautler, Robia G.
    Kinahan, Paul E.
    Muzi, Mark
    Chenevert, Thomas L.
    TOMOGRAPHY, 2023, 9 (01) : 375 - 386