Virtual touch tissue imaging quantification shear wave elastography for determining benign versus malignant cervical lymph nodes: a comparison with conventional ultrasound

被引:8
|
作者
Kilic, Alican [1 ]
Er, Hale Colakoglu [1 ]
机构
[1] Gaziantep Univ, Dept Radiol, Sch Med, Gaziantep, Turkey
关键词
POWER DOPPLER SONOGRAPHY; REAL-TIME ELASTOGRAPHY; DIFFERENTIAL-DIAGNOSIS; HIGH-RESOLUTION; CLINICAL-VALUE; NECK; LYMPHADENOPATHY; HEAD; ULTRASONOGRAPHY; METASTASES;
D O I
10.5152/dir.2019.18406
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE We aimed to prospectively examine virtual touch tissue imaging quantification (VTIQ) shear wave elastography (SWE) and conventional (B-mode and Doppler) ultrasonography (US), individually and combined, for their ability to differentiate benign and malignant cervical lymph nodes (CLNs). METHODS One hundred enlarged lymph nodes (LNs) from 72 patients, confirmed by histopathologic diagnoses, were included in the present study. B-mode US, Doppler US, and SWE were performed before histopathologic sampling of the LNs. The LN shear wave velocity (SWV, m/s) was assessed by VTIQ. RESULTS Using a 3.03 m/s cutoff value, the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of SWVmax for differentiating benign and malignant CLNs were 93%, 59%, 68%, 91%, and 75%, respectively. B-mode and Doppler had a sensitivity, specificity, PPV, NPV, and accuracy of 79.2%, 71.2%, 71.6%, 78.7%, and 75%, respectively. B-mode, Doppler, and VTIQ SWE combined had 87.5%, 75%, 76.3%, 86.6%, and 81% for the same parameters, respectively. CONCLUSION VTIQ SWE is a promising noninvasive diagnostic imaging technique for differentiating benign and malignant CLNs. VTIQ SWV can improve the diagnostic performance of conventional US for differentiating benign and malignant CLNs.
引用
收藏
页码:114 / 121
页数:8
相关论文
共 50 条
  • [41] Comparison of Virtual Touch Tissue Quantification with B-Mode Sonography in the Differential Diagnosis of Superficial Lymph Nodes
    Wu, Ying
    Bai, Min
    Gu, Jiying
    Li, Hongli
    Du, Lianfang
    Li, Fenghua
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2018, 8 (04) : 703 - 708
  • [42] Differentiation of benign and malignant focal liver lesions: value of virtual touch tissue quantification of acoustic radiation force impulse elastography
    Guo, Le-Hang
    Wang, Shu-Jun
    Xu, Hui-Xiong
    Sun, Li-Ping
    Zhang, Yi-Feng
    Xu, Jun-Mei
    Wu, Jian
    Fu, Hui-Jun
    Xu, Xiao-Hong
    MEDICAL ONCOLOGY, 2015, 32 (03)
  • [43] Differentiation of benign and malignant focal liver lesions: value of virtual touch tissue quantification of acoustic radiation force impulse elastography
    Le-Hang Guo
    Shu-Jun Wang
    Hui-Xiong Xu
    Li-Ping Sun
    Yi-Feng Zhang
    Jun-Mei Xu
    Jian Wu
    Hui-Jun Fu
    Xiao-Hong Xu
    Medical Oncology, 2015, 32
  • [44] Virtual touch imaging quantification shear-wave elastography for breast lesions: the diagnostic value of qualitative and quantitative features
    Luo, T.
    Zhang, J. W.
    Zhu, Y.
    Jia, X. H.
    Dong, Y. J.
    Zhan, W. W.
    Zhou, J. Q.
    CLINICAL RADIOLOGY, 2021, 76 (04) : 316.e1 - 316.e8
  • [45] The value of multimodal ultrasound in diagnosis of cervical lymphadenopathy: can real-time elastography help identify benign and malignant lymph nodes?
    Tong, Jiahui
    Lin, Ting
    Wen, Boping
    Chen, Peijun
    Wang, Ying
    Yu, Yuehui
    Chen, Menghan
    Yang, Gaoyi
    FRONTIERS IN ONCOLOGY, 2023, 13
  • [46] Inability of shear-wave elastography to distinguish malignant from benign prostate tissue - a comparison of biopsy, whole-mount sectioning and shear-wave elastography
    Porsch, Markus
    Goerner, Claudia
    Wendler, Johann Jakob
    Liehr, Uwe-Bernd
    Lux, Anke
    Siedentopf, Sandra
    Schostak, Martin
    Pech, Maciej
    JOURNAL OF ULTRASONOGRAPHY, 2016, 16 (67) : 348 - 358
  • [47] Comparison of peritumoral stroma tissue stiffness obtained by shear wave elastography between benign and malignant breast lesions
    Park, Hye Sun
    Shin, Hee Jung
    Shin, Ki Chang
    Cha, Joo Hee
    Chae, Eun Young
    Choi, Woo Jung
    Kim, Hak Hee
    ACTA RADIOLOGICA, 2018, 59 (10) : 1168 - 1175
  • [48] Shear Wave Elastography Combining with Conventional Grey Scale Ultrasound Improves the Diagnostic Accuracy in Differentiating Benign and Malignant Thyroid Nodules
    Baig, Faisal N.
    Liu, Shirley Y. W.
    Lam, Hoi-Chun
    Yip, Shea-Ping
    Law, Helen K. W.
    Ying, Michael
    APPLIED SCIENCES-BASEL, 2017, 7 (11):
  • [49] Nodule size is a key factor for differentiating benign and malignant thyroid nodules using virtual touch tissue quantification and conventional sonography
    Zhang, Huiping
    Gu, Jiying
    Xing, Jinfang
    Bai, Min
    Gao, Feng
    Du, Lianfang
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2017, 10 (05): : 7825 - 7833
  • [50] Differentiation of benign and metastatic axillary lymph nodes in breast cancer: additive value of shear wave elastography to B-mode ultrasound
    Seo, Mirinae
    Sohn, Yu-Mee
    CLINICAL IMAGING, 2018, 50 : 258 - 263