Differentiation of benign and malignant focal liver lesions: value of virtual touch tissue quantification of acoustic radiation force impulse elastography

被引:0
|
作者
Le-Hang Guo
Shu-Jun Wang
Hui-Xiong Xu
Li-Ping Sun
Yi-Feng Zhang
Jun-Mei Xu
Jian Wu
Hui-Jun Fu
Xiao-Hong Xu
机构
[1] Tenth People’s Hospital of Tongji University,Department of Medical Ultrasound, Shanghai Tenth People’s Hospital
[2] Tenth People’s Hospital of Tongji University,Department of Pathology, Shanghai Tenth People’s Hospital
[3] Guangdong Medical College Affiliated Hospital,Department of Ultrasound
来源
Medical Oncology | 2015年 / 32卷
关键词
Acoustic radiation force impulse; Virtual touch quantification; Shear wave velocity; Focal liver lesion;
D O I
暂无
中图分类号
学科分类号
摘要
The purpose of this study was to investigate the value of virtual tissue quantification (VTQ) of acoustic radiation force impulse elastography for the differential diagnosis of benign and malignant focal liver lesions (FLLs). Thus, a total of 134 FLLs in 134 patients were included. VTQ measurement was performed for each lesion in which the shear wave velocity (SWV) was measured. The difference in SWV and SWV ratio of FLL to surrounding liver between malignant and benign FLLs was evaluated, and the cutoff value was investigated. Receiver operating characteristic (ROC) curve was plotted to evaluate the diagnostic performance. A total of 134 lesions including 55 (41.0 %) malignant FLLs and 79 (59.0 %) benign ones were analyzed. The SWV of malignant and benign FLLs was 2.95 ± 1.00 m/s and 1.69 ± 0.89 m/s, respectively. Significant difference in SWV was presented between malignant and benign FLLs (p < 0.001). The SWV ratio of each FLL to the surrounding liver parenchyma was 1.83 ± 1.32 for malignant and 1.26 ± 0.78 for benign FLLs (p < 0.001). The area under the ROC curve in distinguishing malignant from benign lesions was 0.824 for SWV and 0.660 for SWV ratio. The cutoff value for differential diagnosis was 2.13 m/s for SWV and 1.37 for SWV ratio. The associated sensitivity and specificity were 83.3 and 77.9 % for SWV and 59.6 and 77.3 % for SWV ratio, respectively. In conclusion, VTQ provides quantitative stiffness information of FLLs and is helpful in the differential diagnosis between malignant and benign FLLs, particularly for the patients who are not candidates for contrast-enhanced imaging such as CT, MRI or contrast-enhanced ultrasound.
引用
收藏
相关论文
共 50 条
  • [1] Differentiation of benign and malignant focal liver lesions: value of virtual touch tissue quantification of acoustic radiation force impulse elastography
    Guo, Le-Hang
    Wang, Shu-Jun
    Xu, Hui-Xiong
    Sun, Li-Ping
    Zhang, Yi-Feng
    Xu, Jun-Mei
    Wu, Jian
    Fu, Hui-Jun
    Xu, Xiao-Hong
    MEDICAL ONCOLOGY, 2015, 32 (03)
  • [2] The role of acoustic radiation force impulse elastography in the differentiation of benign and malignant focal liver masses
    Akdogan, Emin
    Yilmaz, Feyza Gelebek
    TURKISH JOURNAL OF GASTROENTEROLOGY, 2018, 29 (04): : 456 - 463
  • [3] Acoustic radiation force impulse elastography for differentiation of malignant and benign breast lesions: a meta-analysis
    Li, Dan-Dan
    Guo, Le-Hang
    Xu, Hui-Xiong
    Liu, Chang
    Xu, Jun-Mei
    Sun, Li-Ping
    Wu, Jian
    Liu, Bo-Ji
    Liu, Lin-Na
    Xu, Xiao-Hong
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2015, 8 (04): : 4753 - 4761
  • [4] Diagnostic Value of Acoustic Radiation Force Impulse Quantification in the Differentiation of Benign and Malignant Thyroid Nodules
    Pandey, Niraj Nirmal
    Pradhan, Gaurav Shanker
    Manchanda, Alpana
    Garg, Anju
    ULTRASONIC IMAGING, 2017, 39 (05) : 326 - 336
  • [5] The role of acoustic radiation force impulse elastography in the differentiation of benign and malignant focal liver masses (vol 29, pg 456, 2018)
    Akdogan, E.
    Yilmaz, Gelebek F.
    Comba, A.
    TURKISH JOURNAL OF GASTROENTEROLOGY, 2018, 29 (06): : 722 - 722
  • [6] Elastography by acoustic radiation force impulse technology for differentiation of benign and malignant breast lesions: a meta-analysis
    Liu, BaoXian
    Zheng, YanLing
    Shan, QuanYuan
    Lu, Ying
    Lin, ManXia
    Tian, WenShuo
    Xie, XiaoYan
    JOURNAL OF MEDICAL ULTRASONICS, 2016, 43 (01) : 47 - 55
  • [7] Elastography by acoustic radiation force impulse technology for differentiation of benign and malignant breast lesions: a meta-analysis
    BaoXian Liu
    YanLing Zheng
    QuanYuan Shan
    Ying Lu
    ManXia Lin
    WenShuo Tian
    XiaoYan Xie
    Journal of Medical Ultrasonics, 2016, 43 : 47 - 55
  • [8] Diagnostic value of Virtual Touch Quantification (VTQ®) for differentiation of hemangiomas from malignant focal liver lesions
    Galati, Giovanni
    De Vincentis, Antonio
    Gallo, Paolo
    Guidi, Alessandro
    Vespasiani-Gentilucci, Umberto
    Picardi, Antonio
    MEDICAL ULTRASONOGRAPHY, 2019, 21 (04) : 371 - 376
  • [9] Virtual Touch Tissue Imaging on Acoustic Radiation Force Impulse Elastography A New Technique for Differential Diagnosis Between Benign and Malignant Thyroid Nodules
    Zhang, Yi-Feng
    He, Yong
    Xu, Hui-Xiong
    Xu, Xiao-Hong
    Liu, Chang
    Guo, Le-Hang
    Liu, Lin-Na
    Xu, Jun-Mei
    JOURNAL OF ULTRASOUND IN MEDICINE, 2014, 33 (04) : 585 - 595
  • [10] QUANTIFICATION OF ACOUSTIC RADIATION FORCE IMPULSE IN DIFFERENTIATING BETWEEN MALIGNANT AND BENIGN BREAST LESIONS
    Li, Zhencai
    Sun, Junzhong
    Zhang, Jing
    Hu, Dongmei
    Wang, Qiong
    Peng, Kun
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2014, 40 (02): : 287 - 292