Virtual touch tissue imaging quantification shear wave elastography for determining benign versus malignant cervical lymph nodes: a comparison with conventional ultrasound

被引:8
|
作者
Kilic, Alican [1 ]
Er, Hale Colakoglu [1 ]
机构
[1] Gaziantep Univ, Dept Radiol, Sch Med, Gaziantep, Turkey
关键词
POWER DOPPLER SONOGRAPHY; REAL-TIME ELASTOGRAPHY; DIFFERENTIAL-DIAGNOSIS; HIGH-RESOLUTION; CLINICAL-VALUE; NECK; LYMPHADENOPATHY; HEAD; ULTRASONOGRAPHY; METASTASES;
D O I
10.5152/dir.2019.18406
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE We aimed to prospectively examine virtual touch tissue imaging quantification (VTIQ) shear wave elastography (SWE) and conventional (B-mode and Doppler) ultrasonography (US), individually and combined, for their ability to differentiate benign and malignant cervical lymph nodes (CLNs). METHODS One hundred enlarged lymph nodes (LNs) from 72 patients, confirmed by histopathologic diagnoses, were included in the present study. B-mode US, Doppler US, and SWE were performed before histopathologic sampling of the LNs. The LN shear wave velocity (SWV, m/s) was assessed by VTIQ. RESULTS Using a 3.03 m/s cutoff value, the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of SWVmax for differentiating benign and malignant CLNs were 93%, 59%, 68%, 91%, and 75%, respectively. B-mode and Doppler had a sensitivity, specificity, PPV, NPV, and accuracy of 79.2%, 71.2%, 71.6%, 78.7%, and 75%, respectively. B-mode, Doppler, and VTIQ SWE combined had 87.5%, 75%, 76.3%, 86.6%, and 81% for the same parameters, respectively. CONCLUSION VTIQ SWE is a promising noninvasive diagnostic imaging technique for differentiating benign and malignant CLNs. VTIQ SWV can improve the diagnostic performance of conventional US for differentiating benign and malignant CLNs.
引用
收藏
页码:114 / 121
页数:8
相关论文
共 50 条
  • [31] Comparison of Diagnostic Performance of B-Mode Ultrasonography and Shear Wave Elastography in Cervical Lymph Nodes
    Kang, Hye Jin
    Seo, Mirinae
    Sohn, Yu-Mee
    Yun, Seong Jong
    Min, Sun Young
    You, Myung-Won
    Yeon, Eung Koo
    ULTRASOUND QUARTERLY, 2019, 35 (03) : 290 - 296
  • [32] The diagnostic performance of shear wave elastography for malignant cervical lymph nodes: A systematic review and meta-analysis
    Suh, Chong Hyun
    Choi, Young Jun
    Baek, Jung Hwan
    Lee, Jeong Hyun
    EUROPEAN RADIOLOGY, 2017, 27 (01) : 222 - 230
  • [33] Application of conventional ultrasound coupled with virtual touch tissue imaging and quantification in the assessment of muscle strength
    Zhou, Weichen
    Ma, Xiaojuan
    Pan, Lin
    Wang, Yunhan
    Zhou, Chengting
    ANNALS OF PALLIATIVE MEDICINE, 2020, 9 (05) : 3402 - 3409
  • [34] Prospective Comparison of Liver Stiffness Measurements between Two Point Shear Wave Elastography Methods: Virtual Touch Quantification and Elastography Point Quantification
    Yoo, Hyunsuk
    Lee, Jeong Min
    Yoon, Jeong Hee
    Lee, Dong Ho
    Chang, Won
    Han, Joon Koo
    KOREAN JOURNAL OF RADIOLOGY, 2016, 17 (05) : 750 - 757
  • [35] Shear Wave Elastography: A New Ultrasound Imaging Mode for the Differential Diagnosis of Benign and Malignant Thyroid Nodules
    Sebag, F.
    Vaillant-Lombard, J.
    Berbis, J.
    Griset, V.
    Henry, J. F.
    Petit, P.
    Oliver, C.
    JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2010, 95 (12): : 5281 - 5288
  • [36] The value of virtual touch tissue imaging quantification in the differential diagnosis between benign and malignant breast lesions
    Kong, Wen-tao
    Zhou, Wei-jun
    Wang, Yin
    Zhuang, Xiao-min
    Wu, Min
    JOURNAL OF MEDICAL ULTRASONICS, 2019, 46 (04) : 459 - 466
  • [37] Diagnostic value of virtual touch tissue imaging quantification for benign and malignant breast lesions with different sizes
    Liu, Hui
    Zhao, Li-Xia
    Xu, Guang
    Yao, Ming-Hua
    Zhang, Ai-Hong
    Xu, Hui-Xiong
    Wu, Rong
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2015, 8 (08): : 13118 - 13126
  • [38] The value of virtual touch tissue imaging quantification in the differential diagnosis between benign and malignant breast lesions
    Wen-tao Kong
    Wei-jun Zhou
    Yin Wang
    Xiao-min Zhuang
    Min Wu
    Journal of Medical Ultrasonics, 2019, 46 : 459 - 466
  • [39] The role of ultrasound elastography and virtual touch tissue imaging in the personalized prediction of lymph node metastasis of breast cancer
    Wang, Jue
    Ben, Zhifei
    Gao, Shanshan
    Lyu, Shuyi
    Wei, Xiuzhi
    GLAND SURGERY, 2021, 10 (04) : 1460 - 1469
  • [40] Evaluation of diagnostic value of conventional and color Doppler ultrasound with elastography strain ratios in differentiation between benign and malignant lymph nodes
    Ozel, Deniz
    Ozel, Betul Duran
    POLISH JOURNAL OF RADIOLOGY, 2018, 83 : E32 - E36