Since the abnormal metabolism of bilirubin could lead to diseases in the human body, especially the jaundice which is harmful to neonates. Traditional invasive measurements are difficult to be accepted by people because of pain and infection. Therefore, the real-time and non-invasive measurement of bilirubin is of great significance. However, the accuracy of currently transcutaneous bilirubinometry(TcB) is generally not high enough, and affected by many factors in the human skin, mostly by hemoglobin. In this talk, absorption spectra of hemoglobin and bilirubin have been collected and analyzed, then the Partial Least Squares (PLS) models have been built. By analyzing and comparing the Correlation and Root Mean Square Error of Prediction(RMSEP), the results show that the Correlation of bilirubin solution model is larger than that of the mixture solution added with hemoglobin, and its RMSEP value is smaller than that of mixture solution. Therefore, hemoglobin has influences on the non-invasive optical bilirubin sensing. In next step, it is necessary to investigate how to eliminate the influence.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] A non-invasive hemoglobin measurement based pulse oximetry
    Pothisarn, W
    Chewpraditkul, W
    Yupapin, PP
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS: DIAGNOSTICS AND TREATMENT, 2002, 4916 : 498 - 504
  • [42] Non-Invasive Hemoglobin Blood Level Measurement System
    Hardyanto, Ichsan
    Pambudi, Sabar
    Suyarna, Yaya
    Ardidarma, Arga
    Kurniawan, Ade
    Iskandar, Johan
    RidwanSiskandar
    Jenie, Renan Prasta
    Alatas, Husin
    Irzaman
    9TH NATIONAL PHYSICS SEMINAR 2020, 2021, 2320
  • [43] Influence of cholesterol on non-invasive blood glucose sensing studied with NIR spectroscopy
    Jiang, Jingying
    Zhang, Lingling
    Gong, Qiliang
    Xu, Kexin
    DYNAMICS AND FLUCTUATIONS IN BIOMEDICAL PHOTONICS VIII, 2011, 7898
  • [44] Non-invasive hemoglobin measurement using embedded platform
    Pinto, Caje
    Parab, Jivan
    Naik, Gourish
    SENSING AND BIO-SENSING RESEARCH, 2020, 29
  • [45] Intraoperative evaluation of non-invasive hemoglobin in children with craniosynostosis
    Gurskaia, Viktoriia
    Pulkina, Olga
    Ivanov, Vadim
    Savvina, Irina
    ANESTHESIA AND ANALGESIA, 2021, 133 (3S_SUPPL): : 1222 - 1222
  • [46] Portable Smart Non-Invasive Hemoglobin Measurement System
    Al-Baradie, Raid Saleem
    Bose, Anandh Sam Chandra
    2013 10TH INTERNATIONAL MULTI-CONFERENCE ON SYSTEMS, SIGNALS & DEVICES (SSD), 2013,
  • [47] Progress in non-invasive optical diagnostics
    Khalil, OS
    IN-VITRO DIAGNOSTIC INSTRUMENTATION, 2000, 3913 : 2 - 14
  • [48] Non-invasive optical imaging of stroke
    Obrig, Hellmuth
    Steinbrink, Jens
    PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2011, 369 (1955): : 4470 - 4494
  • [49] NIR-based Sensing System for Non-invasive Detection of Hemoglobin for Point-of-care Applications
    Kumar, Yogesh
    Dogra, Ayush
    Shaw, Vikash
    Kaushik, Ajeet
    Kumar, Sanjeev
    CURRENT MEDICAL IMAGING, 2022, 18 (05) : 532 - 545
  • [50] Non-invasive investigation of skin local hypothermia influence upon local oxygenation and hemoglobin concentration
    Yu, DA
    Kessler, M
    Kakihana, Y
    Krug, A
    OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE: THEORY, INSTRUMENTATION, MODEL, AND HUMAN STUDIES II, PROCEEDINGS OF, 1997, 2979 : 375 - 377