NIR-based Sensing System for Non-invasive Detection of Hemoglobin for Point-of-care Applications

被引:2
|
作者
Kumar, Yogesh [1 ,2 ]
Dogra, Ayush [1 ]
Shaw, Vikash [1 ,2 ]
Kaushik, Ajeet [3 ]
Kumar, Sanjeev [1 ,2 ]
机构
[1] CSIR, Cent Sci Instruments Org, Chandigarh 160030, India
[2] Acad Sci & Innovat Res AcSIR, Ghaziabad 201002, India
[3] Florida Polytech Univ, Hlth Syst Engn Dept Nat Sci, Div Sci Arts & Math, Nano Bio Tech Lab, Lakeland, FL 33805 USA
关键词
Hemoglobin; isosbestic point; non-invasive sensing; optical systems; sliding mechanism; anemia; PULSE CO-OXIMETRY; ACCURACY; VALIDATION; UTILITY; ANEMIA; RISK;
D O I
10.2174/1573405617666210823100316
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Hemoglobin is an essential biomolecule for the transportation of oxygen, therefore, its assessment is also important to be done frequently in numerous clinical practices. Traditional invasive techniques have concomitant shortcomings, such as time delay, the onset of infections, and discomfort, which necessitate a non-invasive hemoglobin estimation solution to get rid of these constraints in health informatics. Currently, various techniques are underway in the allied domain, and scanty products are also feasible in the market. However, due to the low satisfaction rate, invasive solutions are still assumed as the gold standard. Recently introduced technologies effectively evolved as optical spectroscopy and digital photographic concepts on different sensing spots, e.g., fingertip, palpebral conjunctiva, bulbar conjunctiva, and fingernail. Productive sensors develop more than eight wavelengths to compute hemoglobin concentration and four wavelengths to display only Hb-index (trending of hemoglobin) either in disposable adhesive or reusable clip- type sensor's configuration. Objective: This study aims at an optimistic optical spectroscopic technique to measure hemoglobin concentration and conditional usability of non-invasive blood parameters' diagnostics at point-of- care. Methods: Two distinguishable light emitting sources (810 nm and 1300 nm) are utilized at isosbestic points with a single photodetector (800-1700 nm). With this purpose, reusable finger probe assembly is facilitated in transmittance mode based on the newly offered sliding mechanism to block ambient light. Results: Investigation with proposed design presents correlation coefficients between reference hemoglobin and every individual feature, a multivariate linear regression model for highly correlated independent features. Moreover, principal component analytical model with multivariate linear regression offers mean bias of 0.036 and -0.316 g/dL, precision of 0.878 and 0.838 and limits of agreement from -1.685 to 1.758 g/dL and -1.790 to 1.474 g/dL for 18 and 21 principal components, respectively. Conclusion: The encouraging readouts emphasize favorable precision; therefore, it is proposed that the sensing system is amenable to assess hemoglobin in settings with limited resources and strengthening future routes for the point of care applications.
引用
收藏
页码:532 / 545
页数:14
相关论文
共 50 条
  • [1] Invasive and non-invasive point-of-care testing and point-of-care monitoring of the hemoglobin concentration in human blood - how accurate are the data?
    Dietzel, Frank
    Dieterich, Peter
    Doerries, Frank
    Gehring, Hartmut
    Wegerich, Philipp
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2019, 64 (05): : 495 - 506
  • [2] Non-Invasive Measurement of Hemoglobin: Assessment of Two Different Point-of-Care Technologies
    Gayat, Etienne
    Aulagnier, Jerome
    Matthieu, Emmanuel
    Boisson, Mireille
    Fischler, Marc
    PLOS ONE, 2012, 7 (01):
  • [3] Validity of non-invasive point-of-care hemoglobin estimation in healthy and sick children—a method comparison study
    Aditya Bhat
    Amit Upadhyay
    Vijay Jaiswal
    Deepak Chawla
    Dharamveer Singh
    Mithilesh Kumar
    C. P. Yadav
    European Journal of Pediatrics, 2016, 175 : 171 - 179
  • [4] Non-Invasive Point-of-Care Detection of Methamphetamine and Cocaine via Aptamer-Based Lateral Flow Test
    Erkocyigit, Bilge
    Man, Ezgi
    Efecan, Ece
    Ozufuklar, Ozge
    Devecioglu, Deniz
    Bagci, Basak
    Aldemir, Ebru
    Coskunol, Hakan
    Evran, Serap
    Celik, Emine Guler
    BIOSENSORS-BASEL, 2025, 15 (01):
  • [5] Validity of non-invasive point-of-care hemoglobin estimation in healthy and sick children-a method comparison study
    Bhat, Aditya
    Upadhyay, Amit
    Jaiswal, Vijay
    Chawla, Deepak
    Singh, Dharamveer
    Kumar, Mithilesh
    Yadav, C. P.
    EUROPEAN JOURNAL OF PEDIATRICS, 2016, 175 (02) : 171 - 179
  • [6] Point-of-care non-invasive enzyme-cleavable nanosensors for acute transplant rejection detection
    Liu, Shi-Jie
    Ma, Ke
    Liu, Long-Shan
    Wang, Ke
    Zhang, Ying-Ao
    Bi, Zi-Rong
    Chen, Yan-Xu
    Chen, Ke-Zheng
    Wang, Chang-Xi
    Qiao, Sheng-Lin
    BIOSENSORS & BIOELECTRONICS, 2022, 215
  • [7] Non-invasive Point-of-Care Device To Diagnose Acute Mesenteric lschemia
    Abdelrasoul, Gaser N.
    MacKay, Scott
    Salim, Saad Y.
    Ismond, Kathleen P.
    Tamura, Marcus
    Khalifa, Charfeddine
    Mannan, Emma
    Lin, Donghai
    Mandal, Tanushree
    Montgomery, Ruth R.
    Wishart, David S.
    Chen, Jie
    Khadaroo, Rachel G.
    ACS SENSORS, 2018, 3 (11): : 2296 - 2302
  • [8] Simulation and validation of the radial reference point in non-invasive blood glucose sensing by NIR
    Yang, Yue
    Shi, Zhen-Zhi
    Li, Chen-Xi
    Chen, Wen-Liang
    Xu, Ke-Xin
    Nami Jishu yu Jingmi Gongcheng/Nanotechnology and Precision Engineering, 2010, 8 (02): : 114 - 119
  • [9] Detection of voluntary dehydration in paediatric populations using non-invasive point-of-care saliva and urine testing
    Faidah, Nur
    Soraya, Gita, V
    Erlichster, Michael
    Natzir, Rosdiana
    Chana, Gursharan
    Skafidas, Efstratios
    Hardjo, Marhaen
    Ganda, Idham J.
    Bahar, Burhanuddin
    JOURNAL OF PAEDIATRICS AND CHILD HEALTH, 2021, 57 (06) : 813 - 818
  • [10] A Non-Invasive Hemoglobin Detection Device Based on Multispectral Photoplethysmography
    Zhu, Jianming
    Sun, Ruiyang
    Liu, Huiling
    Wang, Tianjiao
    Cai, Lijuan
    Chen, Zhencheng
    Heng, Baoli
    BIOSENSORS-BASEL, 2024, 14 (01):