NIR-based Sensing System for Non-invasive Detection of Hemoglobin for Point-of-care Applications

被引:2
|
作者
Kumar, Yogesh [1 ,2 ]
Dogra, Ayush [1 ]
Shaw, Vikash [1 ,2 ]
Kaushik, Ajeet [3 ]
Kumar, Sanjeev [1 ,2 ]
机构
[1] CSIR, Cent Sci Instruments Org, Chandigarh 160030, India
[2] Acad Sci & Innovat Res AcSIR, Ghaziabad 201002, India
[3] Florida Polytech Univ, Hlth Syst Engn Dept Nat Sci, Div Sci Arts & Math, Nano Bio Tech Lab, Lakeland, FL 33805 USA
关键词
Hemoglobin; isosbestic point; non-invasive sensing; optical systems; sliding mechanism; anemia; PULSE CO-OXIMETRY; ACCURACY; VALIDATION; UTILITY; ANEMIA; RISK;
D O I
10.2174/1573405617666210823100316
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Hemoglobin is an essential biomolecule for the transportation of oxygen, therefore, its assessment is also important to be done frequently in numerous clinical practices. Traditional invasive techniques have concomitant shortcomings, such as time delay, the onset of infections, and discomfort, which necessitate a non-invasive hemoglobin estimation solution to get rid of these constraints in health informatics. Currently, various techniques are underway in the allied domain, and scanty products are also feasible in the market. However, due to the low satisfaction rate, invasive solutions are still assumed as the gold standard. Recently introduced technologies effectively evolved as optical spectroscopy and digital photographic concepts on different sensing spots, e.g., fingertip, palpebral conjunctiva, bulbar conjunctiva, and fingernail. Productive sensors develop more than eight wavelengths to compute hemoglobin concentration and four wavelengths to display only Hb-index (trending of hemoglobin) either in disposable adhesive or reusable clip- type sensor's configuration. Objective: This study aims at an optimistic optical spectroscopic technique to measure hemoglobin concentration and conditional usability of non-invasive blood parameters' diagnostics at point-of- care. Methods: Two distinguishable light emitting sources (810 nm and 1300 nm) are utilized at isosbestic points with a single photodetector (800-1700 nm). With this purpose, reusable finger probe assembly is facilitated in transmittance mode based on the newly offered sliding mechanism to block ambient light. Results: Investigation with proposed design presents correlation coefficients between reference hemoglobin and every individual feature, a multivariate linear regression model for highly correlated independent features. Moreover, principal component analytical model with multivariate linear regression offers mean bias of 0.036 and -0.316 g/dL, precision of 0.878 and 0.838 and limits of agreement from -1.685 to 1.758 g/dL and -1.790 to 1.474 g/dL for 18 and 21 principal components, respectively. Conclusion: The encouraging readouts emphasize favorable precision; therefore, it is proposed that the sensing system is amenable to assess hemoglobin in settings with limited resources and strengthening future routes for the point of care applications.
引用
收藏
页码:532 / 545
页数:14
相关论文
共 50 条
  • [21] Point-of-care molecular diagnostics for the detection of group A Streptococcus in non-invasive skin and soft tissue infections: a validation study
    Close, Ryan M.
    Sutcliffe, Catherine G.
    Galdun, Patrick
    Reid, Angelina
    Askew, Morgan R.
    Davidson, Anne M.
    Kellywood, Kamellia
    Parker, Dennie
    Patel, Jayshree
    Romancito, Eugene
    Brown, Laura B.
    McAuley, James B.
    Hammitt, Laura L.
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2022, 103 (04)
  • [22] Non-invasive Hemoglobin Screening for Detection of Postpartum Anemia
    Das Mahapatra, Partha Pratim
    Mohakud, Nirmal Kumar
    Roy, Chaitali
    Rajagopal, Harshavardhan
    Sharma, Sandeep
    WOMENS HEALTH REPORTS, 2024, 5 (01): : 565 - 571
  • [23] Neurodegenerative diseases early detection and monitoring system for point-of-care applications
    Thakur, Rajiv
    Saini, Anil Kumar
    Taliyan, Rajeev
    Chaturvedi, Nidhi
    MICROCHEMICAL JOURNAL, 2025, 208
  • [24] Accuracy of Noninvasive and Invasive Point-of-Care Hemoglobin Measurement in the Emergency Department
    Wager, A.
    Thomas, A. W.
    Sewatsky, T. P.
    Boas, S.
    O'keefe, M. F.
    Freeman, K.
    ANNALS OF EMERGENCY MEDICINE, 2013, 62 (04) : S41 - S41
  • [25] NONINVASIVE AND INVASIVE POINT-OF-CARE HEMOGLOBIN TESTING FOR BLOOD DONOR QUALIFICATION
    Corradino, M.
    Whitley, P. H.
    Linda, L.
    Graminske, S. J.
    Straus, T.
    Maes, L. A.
    VOX SANGUINIS, 2013, 105 : 110 - 110
  • [26] Naked-eye point-of-care testing platform based on a pH-responsive superwetting surface: toward the non-invasive detection of glucose
    Gao, Zhong Feng
    Sann, Ei Ei
    Lou, Xiaoding
    Liu, Renyi
    Dai, Jun
    Zuo, Xiaolei
    Xia, Fan
    Jiang, Lei
    NPG ASIA MATERIALS, 2018, 10 : 177 - 189
  • [27] Naked-eye point-of-care testing platform based on a pH-responsive superwetting surface: toward the non-invasive detection of glucose
    Zhong Feng Gao
    Ei Ei Sann
    Xiaoding Lou
    Renyi Liu
    Jun Dai
    Xiaolei Zuo
    Fan Xia
    Lei Jiang
    NPG Asia Materials, 2018, 10 : 177 - 189
  • [28] Metal Nanoclusters in Point-of-Care Sensing and Biosensing Applications
    Nasrollahpour, Hassan
    Sanchez, Beatriz Jurado
    Sillanpaa, Mika
    Moradi, Rasoul
    ACS APPLIED NANO MATERIALS, 2023, 6 (14) : 12609 - 12672
  • [29] Joint NIR-BIS Based Non-Invasive Glucose Monitoring System
    Fouad, Mariam M.
    Mahmoud, Duha Y.
    Abd El Ghany, Mohamed A.
    2018 30TH INTERNATIONAL CONFERENCE ON MICROELECTRONICS (ICM), 2018, : 88 - 91
  • [30] Characterization of a Compact and Highly Sensitive Fluorescence-Based Detection System for Point-of-Care Applications
    Obahiagbon, Uwadiae
    Kullman, Dixie
    Smith, Joseph T.
    Katchman, Benjamin A.
    Arafa, Hany
    Anderson, Karen S.
    Christen, Jennifer Blain
    2016 IEEE HEALTHCARE INNOVATION POINT-OF-CARE TECHNOLOGIES CONFERENCE (HI-POCT), 2016, : 117 - 120