NIR-based Sensing System for Non-invasive Detection of Hemoglobin for Point-of-care Applications

被引:2
|
作者
Kumar, Yogesh [1 ,2 ]
Dogra, Ayush [1 ]
Shaw, Vikash [1 ,2 ]
Kaushik, Ajeet [3 ]
Kumar, Sanjeev [1 ,2 ]
机构
[1] CSIR, Cent Sci Instruments Org, Chandigarh 160030, India
[2] Acad Sci & Innovat Res AcSIR, Ghaziabad 201002, India
[3] Florida Polytech Univ, Hlth Syst Engn Dept Nat Sci, Div Sci Arts & Math, Nano Bio Tech Lab, Lakeland, FL 33805 USA
关键词
Hemoglobin; isosbestic point; non-invasive sensing; optical systems; sliding mechanism; anemia; PULSE CO-OXIMETRY; ACCURACY; VALIDATION; UTILITY; ANEMIA; RISK;
D O I
10.2174/1573405617666210823100316
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Hemoglobin is an essential biomolecule for the transportation of oxygen, therefore, its assessment is also important to be done frequently in numerous clinical practices. Traditional invasive techniques have concomitant shortcomings, such as time delay, the onset of infections, and discomfort, which necessitate a non-invasive hemoglobin estimation solution to get rid of these constraints in health informatics. Currently, various techniques are underway in the allied domain, and scanty products are also feasible in the market. However, due to the low satisfaction rate, invasive solutions are still assumed as the gold standard. Recently introduced technologies effectively evolved as optical spectroscopy and digital photographic concepts on different sensing spots, e.g., fingertip, palpebral conjunctiva, bulbar conjunctiva, and fingernail. Productive sensors develop more than eight wavelengths to compute hemoglobin concentration and four wavelengths to display only Hb-index (trending of hemoglobin) either in disposable adhesive or reusable clip- type sensor's configuration. Objective: This study aims at an optimistic optical spectroscopic technique to measure hemoglobin concentration and conditional usability of non-invasive blood parameters' diagnostics at point-of- care. Methods: Two distinguishable light emitting sources (810 nm and 1300 nm) are utilized at isosbestic points with a single photodetector (800-1700 nm). With this purpose, reusable finger probe assembly is facilitated in transmittance mode based on the newly offered sliding mechanism to block ambient light. Results: Investigation with proposed design presents correlation coefficients between reference hemoglobin and every individual feature, a multivariate linear regression model for highly correlated independent features. Moreover, principal component analytical model with multivariate linear regression offers mean bias of 0.036 and -0.316 g/dL, precision of 0.878 and 0.838 and limits of agreement from -1.685 to 1.758 g/dL and -1.790 to 1.474 g/dL for 18 and 21 principal components, respectively. Conclusion: The encouraging readouts emphasize favorable precision; therefore, it is proposed that the sensing system is amenable to assess hemoglobin in settings with limited resources and strengthening future routes for the point of care applications.
引用
收藏
页码:532 / 545
页数:14
相关论文
共 50 条
  • [31] Evaluation of non-invasive diagnostic tools for diarrhea: a systematic review of point-of-care tests and biomarkers
    Patel, Hinal M.
    Kaur, Ms Ravneet
    Ali, Mohammad Haris
    Hadi, Zeenat
    Parikh, Anushri
    Khan, Sheharyar H.
    Kamireddy, Maniteja
    Faiz, Haseeb
    Kamani, Yashkumar G.
    Agarwal, Aman
    Al Hasibuzzaman, Md.
    ANNALS OF MEDICINE AND SURGERY, 2024, 86 (05): : 2951 - 2962
  • [32] Discriminating Hemorrhagic and Ischemic Stroke Using a Novel, Non-Invasive, Point-of-Care Neuromonitoring Platform
    Berti, Liam
    Maza, Andrew
    Wilcox, Madeleine
    Kesinger, Matthew
    STROKE, 2020, 51
  • [33] Infrared Thermal Imaging as a Novel Non-Invasive Point-of-Care Tool to Assess Filarial Lymphoedema
    Kelly-Hope, Louise A.
    Karim, Mohammad Jahirul
    Sultan Mahmood, A. S. M.
    Al Kawsar, Abdullah
    Khair, Abul
    Betts, Hannah
    Douglass, Janet
    Forrer, Armelle
    Taylor, Mark J.
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (11)
  • [34] Sensor System for Non-Invasive Optical Hemoglobin Determination
    Timm, U.
    McGrath, D.
    Lewis, E.
    Kraitl, J.
    Ewald, H.
    2009 IEEE SENSORS, VOLS 1-3, 2009, : AR6 - AR9
  • [35] Surface-enhanced Raman scattering as a potential strategy for wearable flexible sensing and point-of-care testing non-invasive medical diagnosis
    Liu, Guoran
    Mu, Zhimei
    Guo, Jing
    Shan, Ke
    Shang, Xiaoyi
    Yu, Jing
    Liang, Xiu
    FRONTIERS IN CHEMISTRY, 2022, 9
  • [36] Non-Invasive Hemoglobin Blood Level Measurement System
    Hardyanto, Ichsan
    Pambudi, Sabar
    Suyarna, Yaya
    Ardidarma, Arga
    Kurniawan, Ade
    Iskandar, Johan
    RidwanSiskandar
    Jenie, Renan Prasta
    Alatas, Husin
    Irzaman
    9TH NATIONAL PHYSICS SEMINAR 2020, 2021, 2320
  • [37] Portable Smart Non-Invasive Hemoglobin Measurement System
    Al-Baradie, Raid Saleem
    Bose, Anandh Sam Chandra
    2013 10TH INTERNATIONAL MULTI-CONFERENCE ON SYSTEMS, SIGNALS & DEVICES (SSD), 2013,
  • [38] PAPER BASED POINT-OF-CARE DEVICE FOR INTEGRATED ANEMIA DETECTION AND HEMOGLOBIN VARIANT IDENTIFICATION
    An, Ran
    Man, Yuncheng
    Little, Jane A.
    Gurkan, Umut A.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2020, 68 (05) : 1090 - 1090
  • [39] Non-invasive detection to TVC and color of chilled pork based on Vis/NIR spectroscopy
    Zhang, Leilei
    Peng, Yankun
    Liu, Yuanyuan
    Zhao, Juan
    Guo, Hui
    Nongye Jixie Xuebao/Transactions of the Chinese Society for Agricultural Machinery, 2013, 44 (SUPPL.1): : 159 - 164
  • [40] Biochip readout system for point-of-care applications
    Brandenburg, Albrecht
    Curdt, Franziska
    Sulz, Gerd
    Ebling, Frank
    Nestler, Joerg
    Wunderlich, Kai
    Michel, Dirk
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 139 (01) : 245 - 251