Non-invasive hemoglobin measurement using embedded platform

被引:16
|
作者
Pinto, Caje [1 ]
Parab, Jivan [1 ]
Naik, Gourish [1 ]
机构
[1] Goa Univ, Dept Elect, Taleigao 403206, Goa, India
关键词
Anemia; Embedded; Hemoglobin; Photoplethysmography; Signal conditioning;
D O I
10.1016/j.sbsr.2020.100370
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper is based on the design and development of an in-house algorithm system to Estimate Total Hemoglobin in human blood using the Arduino based Embedded system. In our present society, monitoring Hemoglobin of subjects is very important in hospitals to keep track of low/high hemoglobin count during operations, delivery, dialysis, blood donations, perform stress test, monitoring patients in intensive care units, etc. is often done using invasive methods. In our approach, we have designed a finger probe using five LEDs on a multi-chip having wavelengths 670 nm/770 nm/810 nm/850 nm and 950 nm, and a single silicon photo detector with an inbuilt trans-impedance amplifier to acquire the signals through the finger using the Photoplethysmography (PPG) principle. The non-invasive method can be replaced in hospitals and homes to monitor the total hemoglobin level which is in real-time, painless, and infection-free from needles. We have tested our system on 8 subjects for three and five wavelengths and the values were compared to the hemoglobin measured using invasive methods in the pathology laboratory. The result demonstrates that the five wavelengths PPG method significantly improves the measurement accuracy of total hemoglobin, reducing the mean absolute error between the reference and the estimated hemoglobin values from 1.3778 g/dL for three wavelengths PPG to 0.3499 g/dL for five wavelengths PPG. The five wavelengths PPG system designed showed good linearity to estimate hemoglobin with the Regression Coefficient (R-2 = 0.964) compared to three wavelengths PPG system with the Regression Coefficient (R-2 = 0.688).
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Smart Non-Invasive Hemoglobin Measurement Using Portable Embedded Technology
    Tatiparti, Padma
    Chintalapati, Usha Kumari
    INTERNATIONAL JOURNAL OF ONLINE AND BIOMEDICAL ENGINEERING, 2020, 16 (15) : 106 - 120
  • [2] Non-invasive hemoglobin measurement using optical method
    Ranjith, R.
    Priya, S.
    Dharshini, A. S. Kaviya
    Jeeva, J. B.
    HELIYON, 2024, 10 (15)
  • [3] Non-invasive Measurement of Hemoglobin Content in Blood
    Nirupa, Lourdes Albina J.
    Kumar, Jagadeesh, V
    2014 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2014, : 638 - 642
  • [4] Non-invasive Hemoglobin Measurement for Anemia Diagnosis
    Rochmanto, Raditya Artha
    Zakaria, Hasballah
    Alviana, Ratih Devi
    Shahib, Nurhalim
    2017 4TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING, COMPUTER SCIENCE AND INFORMATICS (EECSI), 2017, : 125 - 129
  • [5] Non-invasive sensor for an in vivo hemoglobin measurement
    Kraitl, Jens
    Timm, Ulrich
    Ewald, Hartmut
    Lewis, Elfed
    2011 IEEE SENSORS, 2011, : 276 - 279
  • [6] Accurate Non-Invasive Measurement of Hemoglobin Using Occlusion Spectroscopy Sensor
    Weinstein, A.
    Herzenstein, O.
    Gabis, E.
    Carlebach, E.
    Korenberg, A.
    TRANSFUSION, 2009, 49 : 60A - 61A
  • [7] Improving non-invasive hemoglobin measurement accuracy using nonparametric models
    Man, Jianing
    Zielinski, Martin D.
    Das, Devashish
    Wutthisirisart, Phichet
    Pasupathy, Kalyan S.
    JOURNAL OF BIOMEDICAL INFORMATICS, 2022, 126
  • [8] Non-invasive Measurement of Hemoglobin Concentration Using Magnetic Plethysmo Gram
    Bai, Rezuana J.
    Mohanasankar, S.
    Kumar, Jagadeesh, V
    2016 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2016, : 435 - 440
  • [9] Comparison of optical sensors for non-invasive hemoglobin measurement
    Desai, Brinda
    Chaskar, Uttam
    2016 INTERNATIONAL CONFERENCE ON ELECTRICAL, ELECTRONICS, AND OPTIMIZATION TECHNIQUES (ICEEOT), 2016, : 2211 - 2214
  • [10] A non-invasive hemoglobin measurement based pulse oximetry
    Pothisarn, W
    Chewpraditkul, W
    Yupapin, PP
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS: DIAGNOSTICS AND TREATMENT, 2002, 4916 : 498 - 504