Non-invasive hemoglobin measurement using embedded platform

被引:16
|
作者
Pinto, Caje [1 ]
Parab, Jivan [1 ]
Naik, Gourish [1 ]
机构
[1] Goa Univ, Dept Elect, Taleigao 403206, Goa, India
关键词
Anemia; Embedded; Hemoglobin; Photoplethysmography; Signal conditioning;
D O I
10.1016/j.sbsr.2020.100370
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper is based on the design and development of an in-house algorithm system to Estimate Total Hemoglobin in human blood using the Arduino based Embedded system. In our present society, monitoring Hemoglobin of subjects is very important in hospitals to keep track of low/high hemoglobin count during operations, delivery, dialysis, blood donations, perform stress test, monitoring patients in intensive care units, etc. is often done using invasive methods. In our approach, we have designed a finger probe using five LEDs on a multi-chip having wavelengths 670 nm/770 nm/810 nm/850 nm and 950 nm, and a single silicon photo detector with an inbuilt trans-impedance amplifier to acquire the signals through the finger using the Photoplethysmography (PPG) principle. The non-invasive method can be replaced in hospitals and homes to monitor the total hemoglobin level which is in real-time, painless, and infection-free from needles. We have tested our system on 8 subjects for three and five wavelengths and the values were compared to the hemoglobin measured using invasive methods in the pathology laboratory. The result demonstrates that the five wavelengths PPG method significantly improves the measurement accuracy of total hemoglobin, reducing the mean absolute error between the reference and the estimated hemoglobin values from 1.3778 g/dL for three wavelengths PPG to 0.3499 g/dL for five wavelengths PPG. The five wavelengths PPG system designed showed good linearity to estimate hemoglobin with the Regression Coefficient (R-2 = 0.964) compared to three wavelengths PPG system with the Regression Coefficient (R-2 = 0.688).
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Non-Invasive Measurement of Heart Rate and Hemoglobin Concentration Level Through Fingertip
    Abhishek, Kumar
    Saxena, Amodh Kant
    Sonkar, Ramesh Kumar
    2015 IEEE INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING, INFORMATICS, COMMUNICATION AND ENERGY SYSTEMS (SPICES), 2015,
  • [42] Review on Wavelength for Non-Invasive Blood Hemoglobin Level Measurement Optical Device
    Jenie, Renan Prasta
    Nasiba, Umu
    Rahayu, Ika
    Nurdin, Naufal Muharram
    Husein, Irzaman
    Alatas, Husin
    2ND INTERNATIONAL CONFERENCE ON SCIENCE, MATHEMATICS, ENVIRONMENT, AND EDUCATION, 2019, 2019, 2194
  • [43] Non-invasive measurement of pressure gradients using ultrasound
    Olesen, Jacob Bjerring
    Traberg, Marie Sand
    Pihl, Michael Johannes
    Jensen, Jorgen Arendt
    MEDICAL IMAGING 2013: ULTRASONIC IMAGING, TOMOGRAPHY, AND THERAPY, 2013, 8675
  • [44] Non-invasive Haemoglobin Measurement Using Photoplethysmographic Technique
    Nidhyananthan, S. Selva
    Shahini, R. Dharshana
    Priya, S. Hari
    INTELLIGENT COMMUNICATION TECHNOLOGIES AND VIRTUAL MOBILE NETWORKS, ICICV 2019, 2020, 33 : 311 - 316
  • [45] NON-INVASIVE MEASUREMENT OF MATURITY
    ROCHE, AF
    TYLESHEVSKI, F
    ROGERS, E
    AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 1983, 60 (02) : 246 - 246
  • [46] Non-Invasive Measurement of Stress
    Yildiz, Sedat
    ACTA PHYSIOLOGICA, 2015, 215 : 12 - 13
  • [47] Non-Invasive Hemoglobin Measurements In Anemic Patients
    Goy, Jennifer
    Namazzi, Ruth
    Hume, Heather Ann
    Ddungu, Henry
    Waiswa, Musa K.
    Malhotra, Rohin
    Cook, Deborah J.
    Crowther, Mark A.
    BLOOD, 2013, 122 (21)
  • [48] DETECTION OF ANEMIA BY NON-INVASIVE HEMOGLOBIN SENSOR
    Weinstein, A.
    Herzenstein, O.
    Kononenko, A.
    Gabis, E.
    Korenberg, A.
    Hod, M.
    VOX SANGUINIS, 2013, 105 : 107 - 108
  • [49] Non-invasive Measurement of Brown Fat Metabolism Based on Optoacoustic Imaging of Hemoglobin Gradients
    Reber, Josefine
    Willershaeuser, Monja
    Karlas, Angelos
    Paul-Yuan, Korbinian
    Diot, Gael
    Franz, Daniela
    Fromme, Tobias
    Ovsepian, Saak V.
    Beziere, Nicolas
    Dubikovskaya, Elena
    Karampinos, Dimitrios C.
    Holzapfel, Christina
    Hauner, Hans
    Klingenspor, Martin
    Ntziachristos, Vasilis
    CELL METABOLISM, 2018, 27 (03) : 689 - +
  • [50] LED Based Sensor System for Non-Invasive Measurement of the Hemoglobin Concentration in Human Blood
    Timm, U.
    Lewis, E.
    McGrath, D.
    Kraitl, J.
    Ewald, H.
    13TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, VOLS 1-3, 2009, 23 (1-3): : 825 - +