Non-invasive hemoglobin measurement using embedded platform

被引:16
|
作者
Pinto, Caje [1 ]
Parab, Jivan [1 ]
Naik, Gourish [1 ]
机构
[1] Goa Univ, Dept Elect, Taleigao 403206, Goa, India
关键词
Anemia; Embedded; Hemoglobin; Photoplethysmography; Signal conditioning;
D O I
10.1016/j.sbsr.2020.100370
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper is based on the design and development of an in-house algorithm system to Estimate Total Hemoglobin in human blood using the Arduino based Embedded system. In our present society, monitoring Hemoglobin of subjects is very important in hospitals to keep track of low/high hemoglobin count during operations, delivery, dialysis, blood donations, perform stress test, monitoring patients in intensive care units, etc. is often done using invasive methods. In our approach, we have designed a finger probe using five LEDs on a multi-chip having wavelengths 670 nm/770 nm/810 nm/850 nm and 950 nm, and a single silicon photo detector with an inbuilt trans-impedance amplifier to acquire the signals through the finger using the Photoplethysmography (PPG) principle. The non-invasive method can be replaced in hospitals and homes to monitor the total hemoglobin level which is in real-time, painless, and infection-free from needles. We have tested our system on 8 subjects for three and five wavelengths and the values were compared to the hemoglobin measured using invasive methods in the pathology laboratory. The result demonstrates that the five wavelengths PPG method significantly improves the measurement accuracy of total hemoglobin, reducing the mean absolute error between the reference and the estimated hemoglobin values from 1.3778 g/dL for three wavelengths PPG to 0.3499 g/dL for five wavelengths PPG. The five wavelengths PPG system designed showed good linearity to estimate hemoglobin with the Regression Coefficient (R-2 = 0.964) compared to three wavelengths PPG system with the Regression Coefficient (R-2 = 0.688).
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Non-invasive hemoglobin monitoring
    Joseph, Bellal
    Haider, Ansab
    Rhee, Peter
    INTERNATIONAL JOURNAL OF SURGERY, 2016, 33 : 254 - 257
  • [22] Non-invasive measurement of tumor oxygenation using embedded microparticulate EPR spin probe
    Ilangovan, G
    Bratasz, A
    Kuppusamy, P
    OXYGEN TRANSPORT TO TISSUE XXVI, 2005, 566 : 67 - 73
  • [23] INCREASING ERROR OF NON-INVASIVE HEMOGLOBIN MEASUREMENT AFTER CARDIOPULMONARY BYPASS
    Riess, M.
    Nabor, D. S.
    Pagel, P. S.
    ANESTHESIA AND ANALGESIA, 2013, 116 : 76 - 76
  • [24] MULTIFACTORIAL DEPENDENCY AND EVALUATION OF HEMOGLOBIN, DETERMINED BY NON-INVASIVE AND INVASIVE MEASUREMENT IN BLOOD DONORS
    Bohonek, M. B.
    Petras, M.
    Kricnerova, M.
    Sladkova, E.
    VOX SANGUINIS, 2013, 105 : 116 - 117
  • [25] Non-invasive measurement of hemoglobin during cesarean hysterectomy: a case series
    Butwick, A. J.
    Hilton, G.
    Riley, E. T.
    Carvalho, B.
    INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 2011, 20 (03) : 240 - 245
  • [26] Dynamic Spectrum and BP Neural Network for Non-invasive Hemoglobin Measurement
    Wang, Huiquan
    Li, Gang
    Zhao, Zhe
    Lin, Ling
    LIFE SYSTEM MODELING AND INTELLIGENT COMPUTING, 2010, 6330 : 67 - 74
  • [27] A novel device for the non-invasive measurement of free hemoglobin in blood bags
    Meinke, M
    Friebel, M
    Helfmann, J
    Notter, M
    BIOMEDIZINISCHE TECHNIK, 2005, 50 (1-2): : 2 - 7
  • [28] A Novel Non-Invasive Technology for Hemoglobin Measurement Irrespective of the Skin Color
    Gokhale, S.
    Daggubati, V.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2022, 205
  • [29] Can perioperative hemodilution be monitored with non-invasive measurement of blood hemoglobin?
    Hahn, Robert G.
    Wuethrich, Patrick Y.
    Zdolsek, Joachim H.
    BMC ANESTHESIOLOGY, 2021, 21 (01)
  • [30] Can perioperative hemodilution be monitored with non-invasive measurement of blood hemoglobin?
    Robert G. Hahn
    Patrick Y. Wuethrich
    Joachim H. Zdolsek
    BMC Anesthesiology, 21