Polyaniline Nanowires-Based Electrochemical Immunosensor for Label Free Detection of Japanese Encephalitis Virus

被引:22
|
作者
Chu Van Tuan [1 ,3 ]
Tran Quang Huy [2 ]
Nguyen Van Hieu [3 ]
Mai Anh Tuan [3 ]
Tran Trung [1 ]
机构
[1] Hung Yen Univ Technol & Educ, Khoai Chau, Hung Yen, Vietnam
[2] NIHE, Hanoi, Vietnam
[3] HUST, ITIMS, Hanoi, Vietnam
关键词
Electrochemical immunosensor; Japanese encephalitis virus; Nanowires; Polyaniline; CONDUCTING POLYMERS; IMMOBILIZATION; ANTIBODIES; BIOSENSORS; SERUM;
D O I
10.1080/00032719.2012.755688
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Polyaniline (PANI) conducting polymers have attracted increasing interest as a transducer material for biosensors applications. In this study, we demonstrate the use of PANI nanowires (NWs) as immobilization platforms in the configuration of an electrochemical immunosensor for label free detection of Japanese encephalitis virus. The PANI NWs were synthesized on the surface of an interdigitated platinum (Pt) microelectrode via electrochemical growth. The morphology and characteristics of the PANI NWs on the Pt microelectrode were verified by scanning electron microscopy and Fourier transform infrared spectroscopy. The anti- Japanese encephalitis virus polyclonal IgG antibody was then covalently immobilized on the PANI NWs-coated Pt microelectrode by using 1-ethyl-3-(3-dimethyaminopropyl) carbodiimide (EDC) and N-hydroxysuccinimde (NHS). The detection of Japanese encephalitis virus antigens was analyzed by electrochemical impedance spectroscopy (EIS). The developed PANI NWs-based electrochemical immunosensor could detect the Japanese encephalitis virus with a detection limit below 10ng/ml. The results from EIS analysis also indicate that when the PANI NWs were exposed to nonspecific molecules, a negligible response was found, and it did not impact to the specificity of the sensor in the virus detection. This work shows the potential use of PANI NWs in electrochemical immunosensors for label free detection of other pathogens and small biomolecules.
引用
收藏
页码:1229 / 1240
页数:12
相关论文
共 50 条
  • [21] Carbon Nanoparticles Based Electrochemical Biosensor Strip for Detection of Japanese Encephalitis Virus
    Lai, Huat Choi
    Chin, Suk Fun
    Pang, Suh Cem
    Sum, Magdline Sia Henry
    Perera, David
    JOURNAL OF NANOMATERIALS, 2017, 2017
  • [22] Label-free electrochemical immunosensor for Ochratoxin a detection in coffee samples
    de Oliveira, Jairo Pinto
    Burgos-Florez, Francisco
    Sampaio, Isabella
    Villalba, Pedro
    Zucolotto, Valtencir
    TALANTA, 2023, 260
  • [23] A label-free electrochemical immunosensor for beta-amyloid detection
    Kaushik, Ajeet
    Shah, Pratikkumar
    Vabbina, Phani Kiran
    Jayant, Rahul Dev
    Tiwari, Sneham
    Vashist, Arti
    Yndart, Adriana
    Nair, Madhavan
    ANALYTICAL METHODS, 2016, 8 (31) : 6115 - 6120
  • [24] Miniaturized Electrochemical Immunosensor for Label-Free Detection of Growth Hormone
    Li, Qi
    Li, Nan
    Le Tissier, Paul
    Grattan, David R.
    Kerman, Kagan
    ELECTROANALYSIS, 2012, 24 (06) : 1272 - 1276
  • [25] Carbon nanoparticle modified screen printed carbon electrode as a disposable electrochemical immunosensor strip for the detection of Japanese encephalitis virus
    Suk Fun Chin
    Lih Shan Lim
    Suh Cem Pang
    Magdline Sia Henry Sum
    David Perera
    Microchimica Acta, 2017, 184 : 491 - 497
  • [26] Carbon nanoparticle modified screen printed carbon electrode as a disposable electrochemical immunosensor strip for the detection of Japanese encephalitis virus
    Chin, Suk Fun
    Lim, Lih Shan
    Pang, Suh Cem
    Sum, Magdline Sia Henry
    Perera, David
    MICROCHIMICA ACTA, 2017, 184 (02) : 491 - 497
  • [27] Reagentless and label-free voltammetric immunosensor for carcinoembryonic antigen based on polyaniline nanowires grown on porous conducting polymer composite
    Sun, Xiaotian
    Hui, Ni
    Luo, Xiliang
    MICROCHIMICA ACTA, 2017, 184 (03) : 889 - 896
  • [28] Reagentless and label-free voltammetric immunosensor for carcinoembryonic antigen based on polyaniline nanowires grown on porous conducting polymer composite
    Xiaotian Sun
    Ni Hui
    Xiliang Luo
    Microchimica Acta, 2017, 184 : 889 - 896
  • [29] Label-free immunosensor based on graphene/polyaniline nanocomposite for neutrophil gelatinase-associated lipocalin detection
    Yukird, Jutiporn
    Wongtangprasert, Tossapon
    Rangkupan, Ratthapol
    Chailapakul, Orawon
    Pisitkun, Trairak
    Rodthongkum, Nadnudda
    BIOSENSORS & BIOELECTRONICS, 2017, 87 : 249 - 255
  • [30] Label-free electrochemical immunosensor for direct detection of Citrus Tristeza virus using modified gold electrode
    Haji-Hashemi, Hedieh
    Norouzi, Parviz
    Safarnejad, Mohammad Reza
    Ganjali, Mohammad Reza
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 244 : 211 - 216