Label-free electrochemical immunosensor for Ochratoxin a detection in coffee samples

被引:8
|
作者
de Oliveira, Jairo Pinto [1 ,2 ,5 ]
Burgos-Florez, Francisco [1 ,3 ]
Sampaio, Isabella [1 ]
Villalba, Pedro [4 ]
Zucolotto, Valtencir [1 ]
机构
[1] Univ Sao Paulo, Sao Carlos Inst Phys, Nanomed & Nanotoxicol Grp, CP 369, BR-13560970 Sao Carlos, SP, Brazil
[2] Univ Fed Espirito Santo, Marechal Campos 1468, BR-29040090 Vitoria, Brazil
[3] Univ Simon Bolivar, Fac Ingn, Hlth & Technol Innovat, Barranquilla 080002, Colombia
[4] Univ Norte, Dept Med, Hlth Div, Barranquilla 081007, Colombia
[5] Univ Fed Espirito Santo, Av Marechal Campos 1468, Vitoria, ES, Brazil
关键词
Ochratoxin A; Immunosensor; Label-free; Coffee; Electrochemical biosensor; PHOTOLUMINESCENCE IMMUNOSENSOR; IMPEDIMETRIC IMMUNOSENSOR; SENSITIVE DETECTION; METABOLITES; ASSAY;
D O I
10.1016/j.talanta.2023.124586
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ochratoxin A (OTA) is a nephrotoxic and carcinogenic mycotoxin frequently found in coffee, which directly impacts human health and the economy of many countries. For this reason, there has been a growing need for simple and sensitive tools for the on-site detection of this mycotoxin. In this study, we developed a label-free impedimetric immunosensor to detect OTA. The biosensor was built on a thin-film gold electrode evaporated on glass substrtes, modified with a self-assembled cysteamine monolayer and anti-OTA antibodies. Atomic force microscopy and Microspectroscopy RAMAN confirmed the successful functionalization of the electrodes. The biosensor performance was evaluated by electrochemical impedance spectroscopy and the measurements indi-cated a linear relationship between the change in the impedance values and the OTA concentration in the range from 0.5 to 100 ng mL-1 with a limit of detection of 0.15 ng mL-1. The biosensor was highly selective and did not suffer matrix interference when analyzed in coffee samples. Furthermore, considering the small sample volumes, the short time required for analysis, and the possibility of miniaturization, the developed biosensor represents a promising analytical device for on-site coffee quality analyses.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Highly-efficient electrochemical label-free immunosensor for the detection of ochratoxin A in coffee samples
    Kunene, Kwanele
    Weber, Matthieu
    Sabela, Myalowenkosi
    Voiry, Damien
    Kanchi, Suvardhan
    Bisetty, Krishna
    Bechelany, Mikhael
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2020, 305
  • [2] Label-Free QCM Immunosensor for the Detection of Ochratoxin A
    Pirincci, Serife Seyda
    Ertekin, Ozlem
    Laguna, Duygu Ercan
    Ozen, Fehime Seyma
    Ozturk, Zafer Ziya
    Ozturk, Selma
    [J]. SENSORS, 2018, 18 (04)
  • [3] Label-free photoelectrochemical immunosensor for sensitive detection of Ochratoxin A
    Yang, Jiaojiao
    Gao, Picheng
    Liu, Yixin
    Li, Rongxia
    Ma, Hongmin
    Du, Bin
    Wei, Qin
    [J]. BIOSENSORS & BIOELECTRONICS, 2015, 64 : 13 - 18
  • [4] Label-free impedimetric immunosensor for sensitive detection of ochratoxin A
    Radi, Abd-Elgawad
    Munoz-Berbel, Xavier
    Lates, Vasilica
    Marty, Jean-Louis
    [J]. BIOSENSORS & BIOELECTRONICS, 2009, 24 (07): : 1888 - 1892
  • [5] Detection of Ochratoxin A by Label-Free Liquid Crystal Immunosensor
    Yang Sheng-Yuan
    Tan Hui
    Liu Yan-Mei
    Wu Zhao-Yang
    Shen Guo-Li
    Yu Ru-Qin
    [J]. CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2011, 32 (05): : 1065 - 1069
  • [6] Label-free electrochemical immunosensor for sensitive detection of kanamycin
    Zhao, Yanfang
    Wei, Qin
    Xu, Caixia
    Li, He
    Wu, Dan
    Cai, Yanyan
    Mao, Kexia
    Cui, Zhentao
    Du, Bin
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2011, 155 (02) : 618 - 625
  • [7] Mucin 4 detection with a label-free electrochemical immunosensor
    Hosu, Oana
    Tertis, Mihaela
    Melinte, Gheorghe
    Feier, Bogdan
    Sandulescu, Robert
    Cristea, Cecilia
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2017, 80 : 39 - 43
  • [8] Development of a label-free electrochemical aptasensor for ultrasensitive detection of ochratoxin A
    Hou, Yujiao
    Long, Nan
    Jia, Boyu
    Liao, Xiaofang
    Yang, Minghan
    Fu, Lizhu
    Zhou, Lidong
    Sheng, Ping
    Kong, Weijun
    [J]. FOOD CONTROL, 2022, 135
  • [9] Miniaturized Electrochemical Immunosensor for Label-Free Detection of Growth Hormone
    Li, Qi
    Li, Nan
    Le Tissier, Paul
    Grattan, David R.
    Kerman, Kagan
    [J]. ELECTROANALYSIS, 2012, 24 (06) : 1272 - 1276
  • [10] A label-free electrochemical immunosensor for beta-amyloid detection
    Kaushik, Ajeet
    Shah, Pratikkumar
    Vabbina, Phani Kiran
    Jayant, Rahul Dev
    Tiwari, Sneham
    Vashist, Arti
    Yndart, Adriana
    Nair, Madhavan
    [J]. ANALYTICAL METHODS, 2016, 8 (31) : 6115 - 6120