Development of a screen-printed carbon electrode based disposable enzyme sensor strip for the measurement of glycated albumin

被引:28
|
作者
Hatada, Mika [1 ]
Tsugawa, Wakako [1 ,2 ]
Kamio, Eri [1 ]
Loew, Noya [2 ]
Klonoff, David C. [2 ,3 ]
Sode, Koji [1 ,2 ]
机构
[1] Tokyo Univ Agr & Technol, Dept Biotechnol & Life Sci, Grad Sch Engn, 2-24-16 Naka Cho, Koganei, Tokyo 1848588, Japan
[2] Tokyo Univ Agr & Technol, Inst Global Innovat Res, 2-24-16 Naka Cho, Koganei, Tokyo 1848588, Japan
[3] Mills Peninsula Hlth Serv, Diabet Res Inst, 100 South San Mateo Dr, San Mateo, CA 94401 USA
来源
关键词
Diabetes mellitus; Glycated albumin; Fructosyl amino acid oxidase; Hemoglobin A1c; Point-of-care testing; Screen-printed carbon electrode; FRUCTOSYL-AMINE OXIDASE; HUMAN-SERUM-ALBUMIN; ELECTROCHEMICAL SENSOR; GLUCOSE BIOSENSORS; HEMOGLOBIN; ASSAY; CONSTRUCTION; GLYCEMIA; PROTEIN; SYSTEM;
D O I
10.1016/j.bios.2016.08.005
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Glycated proteins, such as glycated hemoglobin (HbA1c) or glycated albumin (GA) in the blood, are essential indicators of glycemic control for diabetes mellitus. Since GA, compared to HbA1c, is more sensitive to short term changes in glycemic levels, GA is expected to be used as an alternative or together with HbA1c as a surrogate marker indicator for glycemic control. In this paper we report the development of a sensing system for measuring GA by combining an enzyme analysis method, which is already used in clinical practice, with electrochemical principles. We used fructosyl amino acid oxidase, hexaammineruthenium(III) chloride as the electron mediator, and an inexpensive and economically attractive screen-printed carbon electrode. We used chronoamperometry to measure protease-digested GA samples. The developed sensor strips were able to measure protease-digested samples containing GA in very small sample volumes (1.3 mu L) within about 1 min. We also prepared enzyme sensor strips suitable for clinical use in which the enzyme and the mediator were deposited and dried on. This sensor system showed a clear correlation between the GA concentration and the resulting current. The strips were stable following 3 months of storage at 37 degrees C. We conclude that this disposable enzyme sensor strip system for measuring GA is suitable for point-of-care test (POCT) applications. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:167 / 173
页数:7
相关论文
共 50 条
  • [1] Development of an Interdigitated Electrode-Based Disposable Enzyme Sensor Strip for Glycated Albumin Measurement
    Hatada, Mika
    Loew, Noya
    Okuda-Shimazaki, Junko
    Khanwalker, Mukund
    Tsugawa, Wakako
    Mulchandani, Ashok
    Sode, Koji
    [J]. MOLECULES, 2021, 26 (03):
  • [2] Fabrication and Characterization of Planar Screen-Printed Ag/AgCl Reference Electrode for Disposable Sensor Strip
    Idegami, Koutarou
    Chikae, Miyuki
    Nagatani, Naoki
    Tamiya, Eiichi
    Takamura, Yuzuru
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS, 2010, 49 (09)
  • [3] The Study of Urea Nitrogen Biosensor Based on the Disposable Screen-Printed Carbon Electrode
    Chen, Jie
    Chen, Yan-Ping
    Chen, Ping
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (09): : 7794 - 7802
  • [4] Glycated Hemoglobin Electrochemical Immunosensor Based on Screen-Printed Electrode
    Zhao, Yuliang
    Zhang, Hongyu
    Li, Yang
    Wang, Xiaoai
    Zhao, Liang
    Xu, Jianghong
    Zhan, Zhikun
    Zhang, Guanglie
    Li, Wen Jung
    [J]. Biosensors, 2022, 12 (10):
  • [5] Glycated Hemoglobin Electrochemical Immunosensor Based on Screen-Printed Electrode
    Zhao, Yuliang
    Zhang, Hongyu
    Li, Yang
    Wang, Xiaoai
    Zhao, Liang
    Xu, Jianghong
    Zhan, Zhikun
    Zhang, Guanglie
    Li, Wen Jung
    [J]. BIOSENSORS-BASEL, 2022, 12 (10):
  • [6] Disposable screen-printed enzyme sensor for simultaneous determination of starch and glucose
    Hu, T
    Zhang, XE
    Zhang, ZP
    [J]. BIOTECHNOLOGY TECHNIQUES, 1999, 13 (06) : 359 - 362
  • [7] A disposable sensor based on immobilization of acetylcholinesterase to multiwall carbon nanotube modified screen-printed electrode for determination of carbaryl
    Jie Cai
    Dan Du
    [J]. Journal of Applied Electrochemistry, 2008, 38 : 1217 - 1222
  • [8] A disposable sensor based on immobilization of acetylcholinesterase to multiwall carbon nanotube modified screen-printed electrode for determination of carbaryl
    Cai, Jie
    Du, Dan
    [J]. Journal of Applied Electrochemistry, 2008, 38 (09): : 1217 - 1222
  • [9] A disposable sensor based on immobilization of acetylcholinesterase to multiwall carbon nanotube modified screen-printed electrode for determination of carbaryl
    Cai, Jie
    Du, Dan
    [J]. JOURNAL OF APPLIED ELECTROCHEMISTRY, 2008, 38 (09) : 1217 - 1222
  • [10] DEVELOPMENT OF A DISPOSABLE AMPEROMETRIC SENSOR FOR REDUCED NICOTINAMIDE ADENINE-DINUCLEOTIDE BASED ON A CHEMICALLY-MODIFIED SCREEN-PRINTED CARBON ELECTRODE
    SPRULES, SD
    HART, JP
    WRING, SA
    PITTSON, R
    [J]. ANALYST, 1994, 119 (02) : 253 - 257