Development of a screen-printed carbon electrode based disposable enzyme sensor strip for the measurement of glycated albumin

被引:28
|
作者
Hatada, Mika [1 ]
Tsugawa, Wakako [1 ,2 ]
Kamio, Eri [1 ]
Loew, Noya [2 ]
Klonoff, David C. [2 ,3 ]
Sode, Koji [1 ,2 ]
机构
[1] Tokyo Univ Agr & Technol, Dept Biotechnol & Life Sci, Grad Sch Engn, 2-24-16 Naka Cho, Koganei, Tokyo 1848588, Japan
[2] Tokyo Univ Agr & Technol, Inst Global Innovat Res, 2-24-16 Naka Cho, Koganei, Tokyo 1848588, Japan
[3] Mills Peninsula Hlth Serv, Diabet Res Inst, 100 South San Mateo Dr, San Mateo, CA 94401 USA
来源
关键词
Diabetes mellitus; Glycated albumin; Fructosyl amino acid oxidase; Hemoglobin A1c; Point-of-care testing; Screen-printed carbon electrode; FRUCTOSYL-AMINE OXIDASE; HUMAN-SERUM-ALBUMIN; ELECTROCHEMICAL SENSOR; GLUCOSE BIOSENSORS; HEMOGLOBIN; ASSAY; CONSTRUCTION; GLYCEMIA; PROTEIN; SYSTEM;
D O I
10.1016/j.bios.2016.08.005
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Glycated proteins, such as glycated hemoglobin (HbA1c) or glycated albumin (GA) in the blood, are essential indicators of glycemic control for diabetes mellitus. Since GA, compared to HbA1c, is more sensitive to short term changes in glycemic levels, GA is expected to be used as an alternative or together with HbA1c as a surrogate marker indicator for glycemic control. In this paper we report the development of a sensing system for measuring GA by combining an enzyme analysis method, which is already used in clinical practice, with electrochemical principles. We used fructosyl amino acid oxidase, hexaammineruthenium(III) chloride as the electron mediator, and an inexpensive and economically attractive screen-printed carbon electrode. We used chronoamperometry to measure protease-digested GA samples. The developed sensor strips were able to measure protease-digested samples containing GA in very small sample volumes (1.3 mu L) within about 1 min. We also prepared enzyme sensor strips suitable for clinical use in which the enzyme and the mediator were deposited and dried on. This sensor system showed a clear correlation between the GA concentration and the resulting current. The strips were stable following 3 months of storage at 37 degrees C. We conclude that this disposable enzyme sensor strip system for measuring GA is suitable for point-of-care test (POCT) applications. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:167 / 173
页数:7
相关论文
共 50 条
  • [41] Silver-manganese nanocomposite modified screen-printed carbon electrode in the fabrication of an electrochemical, disposable biosensor strip for cystic fibrosis
    Kumar, P. Arun
    Pradeep, Aarathi
    Nair, Bipin Kumar G.
    Babu, T. G. Satheesh
    Suneesh, Punathil Vasu
    [J]. MICROCHIMICA ACTA, 2022, 189 (09)
  • [42] Development of an Electrochemical Sensor Based on Reduced Graphene Oxide Modified Screen-Printed Carbon Electrode for the Determination of Buprenorphine
    Fakhari, Ali Reza
    Sahragard, Ali
    Ahmar, Hamid
    [J]. ELECTROANALYSIS, 2014, 26 (11) : 2474 - 2483
  • [43] Fabrication of a novel screen-printed carbon electrode based disposable sensor for sensitive determination of an endocrine disruptor BPSIP in environmental and biological matrices
    Singh, Ankit Kumar
    Agrahari, Shreanshi
    Gautam, Ravindra Kumar
    Tiwari, Ida
    [J]. MICROCHEMICAL JOURNAL, 2023, 193
  • [44] A disposable molecularly imprinted electrochemical sensor based on screen-printed electrode modified with ordered mesoporous carbon and gold nanoparticles for determination of ractopamine
    Ma, Min
    Zhu, Pei
    Pi, Fuwei
    Ji, Jian
    Sun, Xiulan
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 775 : 171 - 178
  • [45] Development of a disposable sensor for electrocatalytic detection of guanine and ss-DNA using a modified sol-gel screen-printed carbon electrode
    Abbaspour, Abdolkarim
    Baramakeh, Leila
    Nabavizadeh, S. Masould
    [J]. ELECTROCHIMICA ACTA, 2007, 52 (14) : 4798 - 4803
  • [46] Nafion mixed carbon nanotube modified screen-printed carbon electrode as a disposable electrochemical sensor for quantification of Amitraz in honey and longan samples
    Lerdsri, Jamras
    Upan, Jantima
    Jakmunee, Jaroon
    [J]. ELECTROCHIMICA ACTA, 2022, 410
  • [47] Development of 3-hydroxybutyrate dehydrogenase enzyme biosensor based on carbon nanotube-modified screen-printed electrode
    Khorsand, Fahimeh
    Riahi, Siavash
    Fard, Solmaz Eynollahi
    Kashanian, Soheila
    Naeemy, Ali
    Larijani, Bagher
    Omidfar, Kobra
    [J]. IET NANOBIOTECHNOLOGY, 2013, 7 (01) : 1 - 6
  • [48] A Disposable, Screen-Printed Electrode for the Amperometric Determination of Azide Based on the Immobilization with Catalase or Tyrosinase
    Yue Cui
    John P. Barford
    Reinhard Renneberg
    [J]. Analytical Sciences, 2006, 22 : 1279 - 1281
  • [49] Rapid hydrolysis and electrochemical detection of trace carbofuran at a disposable heated screen-printed carbon electrode
    Wei, Hang
    Sun, Jian-Jun
    Wang, Yan-Min
    Li, Xiao
    Chen, Guo-Nan
    [J]. ANALYST, 2008, 133 (11) : 1619 - 1624
  • [50] Electroanalytical Sensor Based on Unmodified Screen-Printed Carbon Electrode for the Determination of Levo-Thyroxine
    Das, Ashis
    Sangaranarayanan, M. V.
    [J]. ELECTROANALYSIS, 2015, 27 (02) : 360 - 367