Development of a screen-printed carbon electrode based disposable enzyme sensor strip for the measurement of glycated albumin

被引:28
|
作者
Hatada, Mika [1 ]
Tsugawa, Wakako [1 ,2 ]
Kamio, Eri [1 ]
Loew, Noya [2 ]
Klonoff, David C. [2 ,3 ]
Sode, Koji [1 ,2 ]
机构
[1] Tokyo Univ Agr & Technol, Dept Biotechnol & Life Sci, Grad Sch Engn, 2-24-16 Naka Cho, Koganei, Tokyo 1848588, Japan
[2] Tokyo Univ Agr & Technol, Inst Global Innovat Res, 2-24-16 Naka Cho, Koganei, Tokyo 1848588, Japan
[3] Mills Peninsula Hlth Serv, Diabet Res Inst, 100 South San Mateo Dr, San Mateo, CA 94401 USA
来源
关键词
Diabetes mellitus; Glycated albumin; Fructosyl amino acid oxidase; Hemoglobin A1c; Point-of-care testing; Screen-printed carbon electrode; FRUCTOSYL-AMINE OXIDASE; HUMAN-SERUM-ALBUMIN; ELECTROCHEMICAL SENSOR; GLUCOSE BIOSENSORS; HEMOGLOBIN; ASSAY; CONSTRUCTION; GLYCEMIA; PROTEIN; SYSTEM;
D O I
10.1016/j.bios.2016.08.005
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Glycated proteins, such as glycated hemoglobin (HbA1c) or glycated albumin (GA) in the blood, are essential indicators of glycemic control for diabetes mellitus. Since GA, compared to HbA1c, is more sensitive to short term changes in glycemic levels, GA is expected to be used as an alternative or together with HbA1c as a surrogate marker indicator for glycemic control. In this paper we report the development of a sensing system for measuring GA by combining an enzyme analysis method, which is already used in clinical practice, with electrochemical principles. We used fructosyl amino acid oxidase, hexaammineruthenium(III) chloride as the electron mediator, and an inexpensive and economically attractive screen-printed carbon electrode. We used chronoamperometry to measure protease-digested GA samples. The developed sensor strips were able to measure protease-digested samples containing GA in very small sample volumes (1.3 mu L) within about 1 min. We also prepared enzyme sensor strips suitable for clinical use in which the enzyme and the mediator were deposited and dried on. This sensor system showed a clear correlation between the GA concentration and the resulting current. The strips were stable following 3 months of storage at 37 degrees C. We conclude that this disposable enzyme sensor strip system for measuring GA is suitable for point-of-care test (POCT) applications. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:167 / 173
页数:7
相关论文
共 50 条
  • [31] Disposable screen-printed antimony film electrode modified with carbon nanotubes/ionic liquid for electrochemical stripping measurement
    Niu, Xiangheng
    Zhao, Hongli
    Lan, Minbo
    [J]. ELECTROCHIMICA ACTA, 2011, 56 (27) : 9921 - 9925
  • [32] SCREEN-PRINTED ENZYME ELECTRODE FOR THE DETERMINATION OF LACTOSE
    JAGER, A
    BILITEWSKI, U
    [J]. ANALYST, 1994, 119 (06) : 1251 - 1255
  • [33] A disposable glucose biosensor based on diffusional mediator dispersed in nanoparticulate membrane on screen-printed carbon electrode
    Gao, ZQ
    Xie, F
    Shariff, M
    Arshad, M
    Ying, JY
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2005, 111 : 339 - 346
  • [34] A disposable glucose biosensor based on diffusional mediator dispersed in nanoparticulate membrane on screen-printed carbon electrode
    Gao, Z
    Xie, F
    Arshad, MSM
    Ying, JY
    [J]. NSTI NANOTECH 2004, VOL 1, TECHNICAL PROCEEDINGS, 2004, : 209 - 212
  • [35] Flow injection electrochemical enzyme immunoassay based on the use of an immunoelectrode strip integrate immunosorbent layer and a screen-printed carbon electrode
    Gao, Q
    Ma, Y
    Cheng, ZL
    Wang, WD
    Yang, MR
    [J]. ANALYTICA CHIMICA ACTA, 2003, 488 (01) : 61 - 70
  • [36] Sensitive Electrochemical Detection of Creatinine at Disposable Screen-Printed Carbon Electrode Mixed with Ferrocenemethanol
    Chen, Ping
    Peng, Yong
    He, Min
    Yan, Xin-Chuang
    Zhang, Yuan
    Liu, You-Nian
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2013, 8 (07): : 8931 - 8939
  • [37] Development of a method for total plasma thiols measurement using a disposable screen-printed carbon, electrode coupled with a MnO2 reactor
    Liao, Chun-Yen
    Zen, Jyh-Myng
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2008, 129 (02) : 896 - 902
  • [38] Disposable paper-based electrochemical sensor utilizing inkjet-printed Polyaniline modified screen-printed carbon electrode for Ascorbic acid detection
    Kit-Anan, Worrapong
    Olarnwanich, Aricha
    Sriprachuabwong, Chakrit
    Karuwan, Chanpen
    Tuantranont, Adisorn
    Wisitsoraat, Anurat
    Srituravanich, Werayut
    Pimpin, Alongkorn
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2012, 685 : 72 - 78
  • [39] Silver-manganese nanocomposite modified screen-printed carbon electrode in the fabrication of an electrochemical, disposable biosensor strip for cystic fibrosis
    P. Arun Kumar
    Aarathi Pradeep
    Bipin Kumar G. Nair
    T. G. Satheesh Babu
    Punathil Vasu Suneesh
    [J]. Microchimica Acta, 2022, 189
  • [40] A novel and Disposable Amperometric Hydrazine Sensor based on Polydimethyldiallylamine Stabilized Copper(II)hexacyanoferrate Nanocubes modified Screen-printed Carbon Electrode
    Ramaraj, Sukanya
    Sakthivel, Rajalakshmi
    Chen, Shen-Ming
    Palanisamy, Selvakumar
    Velusamy, Vijayalakshmi
    Chen, Tse-Wei
    Ramaraj, Sayee Kannan
    Pandian, Kannaiyan
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (06): : 5567 - 5580