Glycated Hemoglobin Electrochemical Immunosensor Based on Screen-Printed Electrode

被引:0
|
作者
Zhao, Yuliang [1 ]
Zhang, Hongyu [2 ]
Li, Yang [3 ]
Wang, Xiaoai [1 ]
Zhao, Liang [4 ]
Xu, Jianghong [5 ]
Zhan, Zhikun [3 ,6 ]
Zhang, Guanglie [7 ]
Li, Wen Jung [2 ]
机构
[1] Northeastern Univ Qinhuangdao, Sch Control Engn, Qinhuangdao 066004, Hebei, Peoples R China
[2] City Univ Hong Kong, Dept Mech Engn, Hong Kong 999077, Peoples R China
[3] Yanshan Univ, Sch Elect Engn, Key Lab Intelligent Rehabil & Neuromodulat Hebei, Qinhuangdao 066004, Hebei, Peoples R China
[4] Dalian Inst Measurement & Testing, Dalian 116033, Peoples R China
[5] Qinhuangdao Hosp Tradit Chinese Med, Qinhuangdao 066004, Hebei, Peoples R China
[6] Northeastern Univ Qinhuangdao, Sch Comp & Commun Engn, Qinhuangdao 066004, Hebei, Peoples R China
[7] City Univ Hong Kong, Shenzhen Res Inst, Shenzhen 518057, Peoples R China
来源
BIOSENSORS-BASEL | 2022年 / 12卷 / 10期
基金
中国国家自然科学基金;
关键词
glycated hemoglobin (HbA1c); screen-printed electrode (SPE); electrochemical immunosensor; differential pulse voltammetry (DPV); cyclic voltammetry (CV); LABEL-FREE IMMUNOSENSOR; DIABETES-MELLITUS; GRAPHENE OXIDE; THIN-FILM; HBA1C; BIOSENSOR; SENSORS; HBA(1C); BINDING; FABRICATION;
D O I
10.3390/bios12100902
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An electrochemical HbA1c sensor with high sensitivity and good specificity is proposed based on the electrochemical immune principle. The reproducibility and conductivity of the electrode are improved by depositing gold nanoparticles (AuNPs) on the surface of the screen-printed electrode (SPE). The HbA1c antibodies are immobilized on the surface of the modified electrode by adsorption to capture the HbA1c in the sample. The hindering effect of HbA1c on the electrode transfer reaction was exploited as the HbA1c detection mechanism. The electrode's properties were characterized by electrochemical impedance spectroscopy (EIS), and the measurement properties of the electrode were analyzed using differential pulse voltammetry (DPV) and cyclic voltammetry (CV). The experimental results show that the peak current signal of the electrochemical immunosensor produced a linear response to HbA1c in the concentration range of 20-200 mu g/mL, a linear relationship coefficient of 0.9812, a detection limit of 15.5 mu g/mL, and a sensitivity of 0.0938 mu A/mu g.mL(-1). The sensor delivered satisfactory repeatability, stability, and anti-interference performance. Due to its small size, high sensitivity, and wide linear detection range, it is expected to play a significant role in managing diabetes at home.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Glycated Hemoglobin Electrochemical Immunosensor Based on Screen-Printed Electrode
    Zhao, Yuliang
    Zhang, Hongyu
    Li, Yang
    Wang, Xiaoai
    Zhao, Liang
    Xu, Jianghong
    Zhan, Zhikun
    Zhang, Guanglie
    Li, Wen Jung
    [J]. Biosensors, 2022, 12 (10):
  • [2] Screen-printed carbon electrode-based electrochemical immunosensor for rapid detection of microalbuminuria
    Tsai, Jang-Zern
    Chen, Ching-Jung
    Settu, Kalpana
    Lin, Yu-Feng
    Chen, Chien-Lung
    Liu, Jen-Tsai
    [J]. BIOSENSORS & BIOELECTRONICS, 2016, 77 : 1175 - 1182
  • [3] Immunosensor for the determination of okadaic acid based on screen-printed electrode
    Tang, A
    Kreuzer, M
    Lehane, M
    Pravda, M
    Guilbault, GG
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2003, 83 (7-8) : 663 - 670
  • [4] Study on electrochemical biosensor based on screen-printed electrode
    Zou, Quan
    Cheng, Gong
    Zhang, Yu
    [J]. MODERN PHYSICS LETTERS B, 2018, 32 (34-36):
  • [5] Carbon nanotube/polysulfone screen-printed electrochemical immunosensor
    Sanchez, Samuel
    Pumera, Martin
    Fabregas, Esteve
    [J]. BIOSENSORS & BIOELECTRONICS, 2007, 23 (03): : 332 - 340
  • [6] Tungsten Disulfide Decorated Screen-Printed Electrodes for Sensing of Glycated Hemoglobin
    Mahobiya, Sunil Kumar
    Balayan, Sapna
    Chauhan, Nidhi
    Khanuja, Manika
    Kuchhal, Naresh K.
    Islam, S. S.
    Jain, Utkarsh
    [J]. ACS OMEGA, 2022, : 34676 - 34684
  • [7] Disposable electrochemical immunosensor for carcinoembryonic antigen using ferrocene liposomes and MWCNT screen-printed electrode
    Viswanathan, Subramanian
    Rani, Chinnakkaruppanan
    Anand, Annadurai Vijay
    Ho, Ja-an Annie
    [J]. BIOSENSORS & BIOELECTRONICS, 2009, 24 (07): : 1984 - 1989
  • [8] Screen-printed diamond electrode: A disposable sensitive electrochemical electrode
    Kondo, Takeshi
    Sakamoto, Hironori
    Kato, Takayoshi
    Horitani, Masaru
    Shitanda, Isao
    Itagaki, Masayuki
    Yuasa, Makoto
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2011, 13 (12) : 1546 - 1549
  • [9] Portable Benzo[a]pyrene Immunosensor Based on the Polyanline Nanofiber Modified Screen-printed Electrode
    Wang, Chunping
    Zhou, Jiedan
    Huang, Yibin
    Liang, Genquan
    Liu, Yingju
    Lei, Hongtao
    [J]. ADVANCED POLYMER SCIENCE AND ENGINEERING, 2011, 221 : 295 - +
  • [10] Towards the development of a single-step immunosensor based on an electrochemical screen-printed electrode strip coupled with immunomagnetic beads
    G. Volpe
    U. Sozzo
    S. Piermarini
    E. Delibato
    G. Palleschi
    D. Moscone
    [J]. Analytical and Bioanalytical Chemistry, 2013, 405 : 655 - 663