Validation of GEANT4, an object-oriented Monte Carlo toolkit, for simulations in medical physics

被引:143
|
作者
Carrier, JF
Archambault, L
Beaulieu, L
Roy, R
机构
[1] CHUQ Pavillon Hotel Dieu Quebec, Dept RadioOncol, Quebec City, PQ G1R 2J6, Canada
[2] CHUQ Pavillon Hotel Dieu Quebec, Ctr Rech Cancerol, Quebec City, PQ G1R 2J6, Canada
[3] Univ Laval, Dept Phys, Quebec City, PQ G1K 7P4, Canada
关键词
Monte Carlo; dosimetry; GEANT4; validation;
D O I
10.1118/1.1644532
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
GEANT4 (GEometry ANd Tracking 4) is an object-oriented Monte Carlo simulation toolkit that has been developed by a worldwide collaboration of scientists. It simulates the passage of particles through matter. In order to validate GEANT4 for medical physics applications, different simulations are conducted. The results are compared to published results based on three Monte Carlo codes widely used in medical physics: MCNP, EGS4, and EGSnrc. When possible, the simulation results are also compared to experimental data. Different geometries are tested (multilayer and homogeneous phantoms), different sources considered (point-source and broad parallel beam), and different primary particles simulated (photons and electrons) at different energies. For the heterogeneous media, there are notable differences between the Monte Carlo codes reaching up to over 5% in relative difference. For the monoenergetic electrons in a homogeneous medium, the difference between GEANT4 and the experimental measurements is similar to the difference between EGSnrc and the experimental measurements; for the depth-dose curves, the difference expressed as a fraction of the peak dose is always smaller than 4%. We conclude that GEANT4 is a promising Monte Carlo simulation toolkit for low-energy medical applications. (C) 2004 American Association of Physicists in Medicine.
引用
收藏
页码:484 / 492
页数:9
相关论文
共 50 条
  • [31] Geant4 - A new Monte Carlo toolkit for simulating space radiation shielding and effects
    Truscott, P
    Lei, F
    Dyer, C
    Ferguson, C
    Gurriaran, R
    Nieminen, P
    Daly, E
    Apostolakis, J
    Giani, S
    Pia, MG
    Urban, L
    Maire, M
    [J]. 2000 IEEE RADIATION EFFECTS DATA WORKSHOP - WORKSHOP RECORD, 2000, : 147 - 152
  • [32] The Geant4 physics validation repository
    Wenzel, H.
    Yarba, J.
    Dotti, A.
    [J]. 21ST INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS (CHEP2015), PARTS 1-9, 2015, 664
  • [33] GATE/Geant4 as a Monte Carlo simulation toolkit for light ion beam dosimetry
    Bolsa-Ferruz, M.
    Palmans, H.
    Carlino, A.
    Stock, M.
    Traneus, E.
    Grevillot, L.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S727 - S728
  • [34] Validating Geant4 with Monte Carlo simulations in the context of nuclear disarmament verification
    Kreutle, Manuel
    Borella, Alessandro
    Hebel, Simon
    Kirchner, Gerald
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1057
  • [35] Validation of Monte Carlo Geant4 code for a 6 MV Varian linac
    EL Bakkali, Jaafar
    EL Bardouni, Tarek
    [J]. JOURNAL OF KING SAUD UNIVERSITY SCIENCE, 2017, 29 (01) : 106 - 113
  • [36] Development of a Full Monte Carlo Therapeutic Dose Calculation Toolkit for Halcyon Using Geant4
    Liu, R.
    Ji, Z.
    Cai, B.
    Hugo, G.
    Mutic, S.
    Zhao, T.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E742 - E742
  • [37] Precision validation of Geant4 electromagnetic physics
    Cirrone, GAP
    Cuttone, G
    Donadio, S
    Grichine, V
    Guatelli, S
    Gumplinger, P
    Ivanchenko, V
    Maire, M
    Mantero, A
    Mascialino, B
    Nieminen, P
    Pandola, L
    Parlati, S
    Pfeiffer, A
    Pia, MG
    Urban, L
    [J]. 2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 482 - 485
  • [38] Physics settings for using the Geant4 toolkit in proton therapy
    Jarlskog, Christina Zacharatou
    Paganetti, Harald
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (03) : 1018 - 1025
  • [39] Assessment of a new multileaf collimator concept using GEANT4 Monte Carlo simulations
    Tacke, MB
    Szymanowski, H
    Oelfke, U
    Schulze, C
    Nuss, S
    Wehrwein, E
    Leidenberger, S
    [J]. MEDICAL PHYSICS, 2006, 33 (04) : 1125 - 1132
  • [40] A framework for Monte Carlo simulation calculations in GEANT4
    Walker, B.
    Figgins, J.
    Comfort, J. R.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 568 (02): : 889 - 895