Validation of GEANT4, an object-oriented Monte Carlo toolkit, for simulations in medical physics

被引:143
|
作者
Carrier, JF
Archambault, L
Beaulieu, L
Roy, R
机构
[1] CHUQ Pavillon Hotel Dieu Quebec, Dept RadioOncol, Quebec City, PQ G1R 2J6, Canada
[2] CHUQ Pavillon Hotel Dieu Quebec, Ctr Rech Cancerol, Quebec City, PQ G1R 2J6, Canada
[3] Univ Laval, Dept Phys, Quebec City, PQ G1K 7P4, Canada
关键词
Monte Carlo; dosimetry; GEANT4; validation;
D O I
10.1118/1.1644532
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
GEANT4 (GEometry ANd Tracking 4) is an object-oriented Monte Carlo simulation toolkit that has been developed by a worldwide collaboration of scientists. It simulates the passage of particles through matter. In order to validate GEANT4 for medical physics applications, different simulations are conducted. The results are compared to published results based on three Monte Carlo codes widely used in medical physics: MCNP, EGS4, and EGSnrc. When possible, the simulation results are also compared to experimental data. Different geometries are tested (multilayer and homogeneous phantoms), different sources considered (point-source and broad parallel beam), and different primary particles simulated (photons and electrons) at different energies. For the heterogeneous media, there are notable differences between the Monte Carlo codes reaching up to over 5% in relative difference. For the monoenergetic electrons in a homogeneous medium, the difference between GEANT4 and the experimental measurements is similar to the difference between EGSnrc and the experimental measurements; for the depth-dose curves, the difference expressed as a fraction of the peak dose is always smaller than 4%. We conclude that GEANT4 is a promising Monte Carlo simulation toolkit for low-energy medical applications. (C) 2004 American Association of Physicists in Medicine.
引用
收藏
页码:484 / 492
页数:9
相关论文
共 50 条
  • [41] A GATE/Geant4 Monte Carlo toolkit for surface dose calculation in VMAT breast cancer radiotherapy
    Arbor, Nicolas
    Gasteuil, Jean
    Noblet, Caroline
    Moreau, Matthieu
    Meyer, Philippe
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 61 : 112 - 117
  • [42] Cytogenetic analysis of 60Co γ-radiation-induced chromosome damage and simulations using the Geant4 Monte Carlo toolkit
    Fourie, H.
    Newman, R. T.
    Slabbert, J. P.
    Beukes, P.
    [J]. PROCEEDINGS OF SAIP2013: THE 58TH ANNUAL CONFERENCE OF THE SOUTH AFRICAN INSTITUTE OF PHYSICS, 2013, : 248 - 253
  • [43] A comparison of cellular irradiation techniques with alpha particles using the Geant4 Monte Carlo simulation toolkit
    Incerti, S.
    Gault, N.
    Habchi, C.
    Lefaix, J. L.
    Moretto, Ph.
    Poncy, J. L.
    Pouthier, T.
    Seznec, H.
    [J]. RADIATION PROTECTION DOSIMETRY, 2006, 122 (1-4) : 327 - 329
  • [44] Optical physics of scintillation imagers by GEANT4 simulations
    Lo Meo, Sergio
    Baldazzi, Giuseppe
    Bennati, Paolo
    Bollini, Dante
    Cencelli, Valentino O.
    Cinti, Maria N.
    Moschini, Giuliano
    Lanconelli, Nico
    Navarria, Francesco L.
    Pani, Roberto
    Pellegrini, Rosanna
    Perrotta, Andrea
    Vittorini, Francesca
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 607 (01): : 259 - 260
  • [45] Recent Developments and Validation of Geant4 Hadronic Physics
    Yarba, Julia
    [J]. INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS 2012 (CHEP2012), PTS 1-6, 2012, 396
  • [46] Geant4 and Beyond: Precision Physics Modeling and Validation
    Basaglia, Tullio
    Batic, Matej
    Begalli, Marcia
    Han, Min Cheol
    Hauf, Steffen
    Hoff, Gabriela
    Kim, Chan Hyeong
    Kim, Han Sung
    Kim, Sung Hun
    Kuster, Markus
    Pia, Maria Grazia
    Saracco, Paolo
    Weidenspointer, Georg
    [J]. 2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [47] Validation and verification of Geant4 standard electromagnetic physics
    Apostolakis, J.
    Bagulya, A.
    Elles, S.
    Ivanchenko, V. N.
    Jacquemier, J.
    Maire, M.
    Toshito, T.
    Urban, L.
    [J]. 17TH INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS (CHEP09), 2010, 219
  • [48] The Importance of Monte Carlo (Geant4) Physics Settings for Clinical Proton Therapy Treatment Plans
    Winterhalter, C.
    Taylor, M.
    Boersma, D.
    Elia, A.
    Guatelli, S.
    Mackay, R.
    Kirkby, K.
    Maigne, L.
    Ivanchenko, V.
    Resch, A.
    Sarrut, D.
    Sitch, P.
    Vidal, M.
    Grevillot, L.
    Aitkenhead, A.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E862 - E862
  • [49] Progress in Geant4 Electromagnetic Physics Modelling and Validation
    Apostolakis, J.
    Asai, M.
    Bagulya, A.
    Brown, J. M. C.
    Burkhardt, H.
    Chikuma, N.
    Cortes-Giraldo, M. A.
    Elles, S.
    Grichine, V.
    Guatelli, S.
    Incerti, S.
    Ivanchenko, V. N.
    Jacquemier, J.
    Kadri, O.
    Maire, M.
    Pandola, L.
    Sawkey, D.
    Toshito, T.
    Urban, L.
    Yamashita, T.
    [J]. 21ST INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS (CHEP2015), PARTS 1-9, 2015, 664
  • [50] PRELIMINARY STUDY OF PROTON RADIOGRAPHY IMAGING QUALITIES USING GEANT4 MONTE CARLO SIMULATIONS
    Depauw, Nicolas
    Danto, Sylvain
    Bednarz, Bryan
    Paganetti, Harald
    Fink, Yoel
    Seco, Joao