Calibration and field evaluation of polar organic chemical integrative sampler (POCIS) for monitoring pharmaceuticals in hospital wastewater

被引:62
|
作者
Bailly, Emilie [1 ]
Levi, Yves [1 ]
Karolak, Sara [1 ]
机构
[1] Univ Paris 11, Fac Pharmaceut Sci, AgroParisTech, CNRS,Publ Hlth & Environm Lab,UMR 8079, F-92290 Chatenay Malabry, France
关键词
POCIS; Pharmaceuticals; Hospital wastewaters; Water pollution; Modeling; SOLID-PHASE EXTRACTION; PERSONAL CARE PRODUCTS; RISK-ASSESSMENT; MASS-SPECTROMETRY; SURFACE-WATER; SEWAGE WATER; EFFLUENT; CONTAMINANTS; ENVIRONMENT; 5-FLUOROURACIL;
D O I
10.1016/j.envpol.2012.10.025
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The Polar Organic Chemical Integrative Sampler (POCIS) is a new tool for the sampling of organic pollutants in water. We tested this device for the monitoring of pharmaceuticals in hospital wastewater. After calibration, a field application was carried out in a French hospital for six pharmaceutical compounds (Atenolol, Prednisolone, Methylprednisolone, Sulfamethoxazole, Ofloxacin, Ketoprofen). POCIS were calibrated in tap water and wastewater in laboratory conditions close to relevant environmental conditions (temperature, flow velocity). Sampling rates (R-s) were determined and we observed a significant increase with flow velocity and temperature. Whatever the compound, the Rs value was lower in wastewater and the linear phase of uptake was shorter. POCIS were deployed in a hospital sewage pipe during four days and the estimated water concentrations were close to those obtained with twenty-four hour composite samples. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:100 / 105
页数:6
相关论文
共 50 条
  • [1] In situ calibration of polar organic chemical integrative sampler (POCIS) for monitoring of pharmaceuticals in surface waters
    Vrana, Branislav
    Urik, Jakub
    Fedorova, Ganna
    Svecova, Helena
    Grabicova, Katerina
    Golovko, Oksana
    Randak, Tomas
    Grabic, Roman
    ENVIRONMENTAL POLLUTION, 2021, 269 (269)
  • [2] Development and Calibration of the Polar Organic Chemical Integrative Sampler (POCIS) for Neonicotinoid Pesticides
    Noro, Kazushi
    Endo, Satoshi
    Shikano, Yohei
    Banno, Arisa
    Yabuki, Yoshinori
    ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 2020, 39 (07) : 1325 - 1333
  • [3] Polar organic chemical integrative sampler (POCIS): application for monitoring organic micropollutants in wastewater effluent and surface water
    Miege, Cecile
    Budzinski, Helene
    Jacquet, Romain
    Soulier, Coralie
    Pelte, Thomas
    Coquery, Marina
    JOURNAL OF ENVIRONMENTAL MONITORING, 2012, 14 (02): : 626 - 635
  • [4] Determination of naproxen, ibuprofen and triclosan in wastewater using the polar organic chemical integrative sampler (POCIS): A laboratory calibration and field application
    Amdany, Robert
    Chimuka, Luke
    Cukrowska, Ewa
    WATER SA, 2014, 40 (03) : 407 - 414
  • [5] Chemical calibration, performance, validation and applications of the polar organic chemical integrative sampler (POCIS) in aquatic environments
    Morin, Nicolas
    Miege, Cecile
    Randon, Jerome
    Coquery, Marina
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2012, 36 : 144 - 175
  • [6] Development of the performance reference compound approach for the calibration of “polar organic chemical integrative sampler” (POCIS)
    Angel Belles
    Nathalie Tapie
    Patrick Pardon
    Hélène Budzinski
    Analytical and Bioanalytical Chemistry, 2014, 406 : 1131 - 1140
  • [7] Development of the performance reference compound approach for the calibration of "polar organic chemical integrative sampler" (POCIS)
    Belles, Angel
    Tapie, Nathalie
    Pardon, Patrick
    Budzinski, Helene
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (04) : 1131 - 1140
  • [8] Sampling Rate of Polar Organic Chemical Integrative Sampler (POCIS): Influence Factors and Calibration Methods
    Wang, Liyang
    Liu, Ruixia
    Liu, Xiaoling
    Gao, Hongjie
    APPLIED SCIENCES-BASEL, 2020, 10 (16):
  • [9] Laboratory calibration and field deployment of the polar organic chemical integrative sampler for pharmaceuticals and personal care products in wastewater and surface water
    Macleod, Sherri L.
    Mcclure, Evelyn L.
    Wong, Charles S.
    ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 2007, 26 (12) : 2517 - 2529
  • [10] Polar organic chemical integrative sampler (POCIS) uptake rates for 17 polar pesticides and degradation products: laboratory calibration
    Ibrahim, Imtiaz
    Togola, Anne
    Gonzalez, Catherine
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2013, 20 (06) : 3679 - 3687