Calibration and field evaluation of polar organic chemical integrative sampler (POCIS) for monitoring pharmaceuticals in hospital wastewater

被引:62
|
作者
Bailly, Emilie [1 ]
Levi, Yves [1 ]
Karolak, Sara [1 ]
机构
[1] Univ Paris 11, Fac Pharmaceut Sci, AgroParisTech, CNRS,Publ Hlth & Environm Lab,UMR 8079, F-92290 Chatenay Malabry, France
关键词
POCIS; Pharmaceuticals; Hospital wastewaters; Water pollution; Modeling; SOLID-PHASE EXTRACTION; PERSONAL CARE PRODUCTS; RISK-ASSESSMENT; MASS-SPECTROMETRY; SURFACE-WATER; SEWAGE WATER; EFFLUENT; CONTAMINANTS; ENVIRONMENT; 5-FLUOROURACIL;
D O I
10.1016/j.envpol.2012.10.025
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The Polar Organic Chemical Integrative Sampler (POCIS) is a new tool for the sampling of organic pollutants in water. We tested this device for the monitoring of pharmaceuticals in hospital wastewater. After calibration, a field application was carried out in a French hospital for six pharmaceutical compounds (Atenolol, Prednisolone, Methylprednisolone, Sulfamethoxazole, Ofloxacin, Ketoprofen). POCIS were calibrated in tap water and wastewater in laboratory conditions close to relevant environmental conditions (temperature, flow velocity). Sampling rates (R-s) were determined and we observed a significant increase with flow velocity and temperature. Whatever the compound, the Rs value was lower in wastewater and the linear phase of uptake was shorter. POCIS were deployed in a hospital sewage pipe during four days and the estimated water concentrations were close to those obtained with twenty-four hour composite samples. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:100 / 105
页数:6
相关论文
共 50 条
  • [21] Effects of Environmentally Relevant Concentration Exposure Profiles on Polar Organic Chemical Integrative Sampler (POCIS) Sampling Rates
    Taylor, Raegyn B.
    Djomte, Valerie Toteu
    Bobbitt, Jonathan M.
    Hering, Amanda S.
    Chen, Sunmao
    Chambliss, C. Kevin
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2020, 54 (14) : 8848 - 8856
  • [22] Compatibility of polar organic chemical integrative sampler (POCIS) with compound specific isotope analysis (CSIA) of substituted chlorobenzenes
    Suchana, Shamsunnahar
    Edwards, Elizabeth
    Mack, E. Erin
    Lomheim, Line
    Melo, Natanna
    Gavazza, Savia
    Passeport, Elodie
    SCIENCE OF THE TOTAL ENVIRONMENT, 2024, 906
  • [23] Investigation of polar organic chemical integrative sampler (POCIS) flow rate dependence for munition constituents in underwater environments
    Lotufo, Guilherme R.
    George, Robert D.
    Belden, Jason B.
    Woodley, Christa M.
    Smith, David L.
    Rosen, Gunther
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2018, 190 (03)
  • [24] Mass transfer characteristics of chiral pharmaceuticals on membrane used for polar organic chemical integrative sampler
    Wang, Liyang
    Liu, Ruixia
    Zhou, Youya
    Yuan, Peng
    Liu, Xiaoling
    Gao, Hongjie
    JOURNAL OF ENVIRONMENTAL SCIENCES, 2024, 136 : 670 - 681
  • [25] Detection of pharmaceuticals in wastewater effluents-a comparison of the performance of Chemcatcher® and polar organic compound integrative sampler
    Gravell, Anthony
    Fones, Gary R.
    Greenwood, Richard
    Mills, Graham A.
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2020, 27 (22) : 27995 - 28005
  • [26] Atrazine contamination at the watershed scale and environmental factors affecting sampling rates of the polar organic chemical integrative sampler (POCIS)
    Dalton, Rebecca L.
    Pick, Frances R.
    Boutin, Celine
    Saleem, Ammar
    ENVIRONMENTAL POLLUTION, 2014, 189 : 134 - 142
  • [27] Uptake of some selected aquatic pollutants in semipermeable membrane devices (SPMDs) and the polar organic chemical integrative sampler (POCIS)
    Harman, Christopher
    Boyum, Olav
    Tollefsen, Knut Erik
    Thomas, Kevin
    Grung, Merete
    JOURNAL OF ENVIRONMENTAL MONITORING, 2008, 10 (02): : 239 - 247
  • [28] Estimating pesticide sampling rates by the polar organic chemical integrative sampler (POCIS) in the presence of natural organic matter and varying hydrodynamic conditions
    Charlestra, Lucner
    Amirbahman, Aria
    Courtemanch, David L.
    Alvarez, David A.
    Patterson, Howard
    ENVIRONMENTAL POLLUTION, 2012, 169 : 98 - 104
  • [29] Use of Mixed-Mode Ion Exchange Sorbent for the Passive Sampling of Organic Acids by Polar Organic Chemical Integrative Sampler (POCIS)
    Fauvelle, Vincent
    Mazzella, Nicolas
    Delmas, Francois
    Madarassou, Karine
    Eon, Melissa
    Budzinski, Helene
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2012, 46 (24) : 13344 - 13353
  • [30] Monitoring alkylphenols in water using the polar organic chemical integrative sampler (POCIS): Determining sampling rates via the extraction of PES membranes and Oasis beads
    Silvani, Ludovica
    Riccardi, Carmela
    Eek, Espen
    Papini, Marco Petrangeli
    Morin, Nicolas A. O.
    Cornelissen, Gerard
    Oen, Amy M. P.
    Hale, Sarah E.
    CHEMOSPHERE, 2017, 184 : 1362 - 1371