Calibration and field evaluation of polar organic chemical integrative sampler (POCIS) for monitoring pharmaceuticals in hospital wastewater

被引:62
|
作者
Bailly, Emilie [1 ]
Levi, Yves [1 ]
Karolak, Sara [1 ]
机构
[1] Univ Paris 11, Fac Pharmaceut Sci, AgroParisTech, CNRS,Publ Hlth & Environm Lab,UMR 8079, F-92290 Chatenay Malabry, France
关键词
POCIS; Pharmaceuticals; Hospital wastewaters; Water pollution; Modeling; SOLID-PHASE EXTRACTION; PERSONAL CARE PRODUCTS; RISK-ASSESSMENT; MASS-SPECTROMETRY; SURFACE-WATER; SEWAGE WATER; EFFLUENT; CONTAMINANTS; ENVIRONMENT; 5-FLUOROURACIL;
D O I
10.1016/j.envpol.2012.10.025
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The Polar Organic Chemical Integrative Sampler (POCIS) is a new tool for the sampling of organic pollutants in water. We tested this device for the monitoring of pharmaceuticals in hospital wastewater. After calibration, a field application was carried out in a French hospital for six pharmaceutical compounds (Atenolol, Prednisolone, Methylprednisolone, Sulfamethoxazole, Ofloxacin, Ketoprofen). POCIS were calibrated in tap water and wastewater in laboratory conditions close to relevant environmental conditions (temperature, flow velocity). Sampling rates (R-s) were determined and we observed a significant increase with flow velocity and temperature. Whatever the compound, the Rs value was lower in wastewater and the linear phase of uptake was shorter. POCIS were deployed in a hospital sewage pipe during four days and the estimated water concentrations were close to those obtained with twenty-four hour composite samples. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:100 / 105
页数:6
相关论文
共 50 条
  • [31] Development of semipermeable membrane devices (SPMDs) and polar organic chemical integrative samplers (POCIS) for environmental monitoring
    Alvarez, David A.
    ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 2013, 32 (10) : 2179 - 2181
  • [32] A POCIS-based approach for the monitoring of pharmaceuticals in wastewater treatment plants: Calibration and deployment challenges
    Dominguez-Garcia, Pol
    Almirall, Xavier Ortiz
    Gomez-Canela, Cristian
    ENVIRONMENTAL POLLUTION, 2025, 367
  • [33] A Review of In Situ Methods-Solid Phase Adsorption Toxin Tracking (SPATT) and Polar Organic Chemical Integrative Sampler (POCIS) for the Collection and Concentration of Marine Biotoxins and Pharmaceuticals in Environmental Waters
    Kamali, Naghmeh
    Abbas, Feras
    Lehane, Mary
    Griew, Michael
    Furey, Ambrose
    MOLECULES, 2022, 27 (22):
  • [34] Optimization of the polar organic chemical integrative sampler for the sampling of acidic and polar herbicides
    Fauvelle, Vincent
    Mazzella, Nicolas
    Belles, Angel
    Moreira, Aurelie
    Allan, Ian J.
    Budzinski, Helene
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (13) : 3191 - 3199
  • [35] Optimization of the polar organic chemical integrative sampler for the sampling of acidic and polar herbicides
    Vincent Fauvelle
    Nicolas Mazzella
    Angel Belles
    Aurélie Moreira
    Ian J. Allan
    Hélène Budzinski
    Analytical and Bioanalytical Chemistry, 2014, 406 : 3191 - 3199
  • [36] Evaluation of performance reference compounds (PRCs) to monitor emerging polar contaminants by polar organic chemical integrative samplers (POCIS) in rivers
    Carpinteiro, Inmaculada
    Schopfer, Adrien
    Estoppey, Nicolas
    Fong, Camille
    Grandjean, Dominique
    de Alencastro, Luiz F.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (04) : 1067 - 1078
  • [37] Evaluation of performance reference compounds (PRCs) to monitor emerging polar contaminants by polar organic chemical integrative samplers (POCIS) in rivers
    Inmaculada Carpinteiro
    Adrien Schopfer
    Nicolas Estoppey
    Camille Fong
    Dominique Grandjean
    Luiz F. de Alencastro
    Analytical and Bioanalytical Chemistry, 2016, 408 : 1067 - 1078
  • [38] Temperature dependence on the pesticide sampling rate of polar organic chemical integrative samplers (POCIS)
    Yabuki, Yoshinori
    Nagai, Takashi
    Inao, Keiya
    Ono, Junko
    Aiko, Nobuyuki
    Ohtsuka, Nobutoshi
    Tanaka, Hitoshi
    Tanimori, Shinji
    BIOSCIENCE BIOTECHNOLOGY AND BIOCHEMISTRY, 2016, 80 (10) : 2069 - 2075
  • [39] Development of an adapted version of polar organic chemical integrative samplers (POCIS-Nylon)
    Belles, Angel
    Pardon, Patrick
    Budzinski, Helene
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (04) : 1099 - 1110
  • [40] Development of an adapted version of polar organic chemical integrative samplers (POCIS-Nylon)
    Angel Belles
    Patrick Pardon
    Hélène Budzinski
    Analytical and Bioanalytical Chemistry, 2014, 406 : 1099 - 1110