Sampling Rate of Polar Organic Chemical Integrative Sampler (POCIS): Influence Factors and Calibration Methods

被引:13
|
作者
Wang, Liyang [1 ,2 ]
Liu, Ruixia [1 ,2 ]
Liu, Xiaoling [1 ]
Gao, Hongjie [1 ]
机构
[1] Chinese Res Inst Environm Sci, State Key Lab Environm Criteria & Risk Assessment, Beijing 100012, Peoples R China
[2] Beijing Normal Univ, Coll Water Sci, Beijing 100875, Peoples R China
来源
APPLIED SCIENCES-BASEL | 2020年 / 10卷 / 16期
基金
中国国家自然科学基金;
关键词
passive sampling; POCIS; sampling rate; influence factors; calibration; IN-SITU CALIBRATION; SEMIPERMEABLE-MEMBRANE DEVICES; POLYCYCLIC AROMATIC-HYDROCARBONS; REFERENCE COMPOUND APPROACH; PERSONAL CARE PRODUCTS; PASSIVE SAMPLERS; WASTE-WATER; PERFLUORINATED CHEMICALS; LABORATORY CALIBRATION; EMERGING CONTAMINANTS;
D O I
10.3390/app10165548
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
As a passive sampling device, the polar organic chemical integrative sampler (POCIS) has the characteristics of simple operation, safety, and reliability for assessing the occurrence and risk of persistent and emerging trace organic pollutants. The POCIS, allowing for the determination of time-weighted average (TWA) concentration of polar organic chemicals, exhibits good application prospects in aquatic environments. Before deploying the device in water, the sampling rate (R-s), which is a key parameter for characterizing pollutant enrichment, should be determined and calibrated accurately. However, theR(s)values strongly depend on experimental hydrodynamic conditions. This paper provides an overview of the current situation of the POCIS for environmental monitoring of organic pollutants in an aquatic system. The principle and theory of the POCIS are outlined. In particular, the effect factors such as the ambient conditions, pollutant properties, and device features on theR(s)are analyzed in detail from aspects of impact dependence and mechanisms. The calibration methods of theR(s)under laboratory and in situ conditions are summarized. This review offers supplementary information on comprehensive understanding of mechanism and application of the POCIS. Nevertheless, theR(s)were impacted by a combined effect of solute-sorbent-membrane-solution, and the influence extent of each variable was still unclear. On this basis, the ongoing challenges are proposed for the future application of the POCIS in the actual environment, for instance, the need for this device to be improved in terms of quantitative methods for more accurate measurement of theR(s).
引用
收藏
页数:20
相关论文
共 50 条
  • [1] Development and Calibration of the Polar Organic Chemical Integrative Sampler (POCIS) for Neonicotinoid Pesticides
    Noro, Kazushi
    Endo, Satoshi
    Shikano, Yohei
    Banno, Arisa
    Yabuki, Yoshinori
    ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 2020, 39 (07) : 1325 - 1333
  • [2] Chemical calibration, performance, validation and applications of the polar organic chemical integrative sampler (POCIS) in aquatic environments
    Morin, Nicolas
    Miege, Cecile
    Randon, Jerome
    Coquery, Marina
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2012, 36 : 144 - 175
  • [3] Development of the performance reference compound approach for the calibration of “polar organic chemical integrative sampler” (POCIS)
    Angel Belles
    Nathalie Tapie
    Patrick Pardon
    Hélène Budzinski
    Analytical and Bioanalytical Chemistry, 2014, 406 : 1131 - 1140
  • [4] In situ calibration of polar organic chemical integrative sampler (POCIS) for monitoring of pharmaceuticals in surface waters
    Vrana, Branislav
    Urik, Jakub
    Fedorova, Ganna
    Svecova, Helena
    Grabicova, Katerina
    Golovko, Oksana
    Randak, Tomas
    Grabic, Roman
    ENVIRONMENTAL POLLUTION, 2021, 269 (269)
  • [5] Development of the performance reference compound approach for the calibration of "polar organic chemical integrative sampler" (POCIS)
    Belles, Angel
    Tapie, Nathalie
    Pardon, Patrick
    Budzinski, Helene
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (04) : 1131 - 1140
  • [6] Atrazine contamination at the watershed scale and environmental factors affecting sampling rates of the polar organic chemical integrative sampler (POCIS)
    Dalton, Rebecca L.
    Pick, Frances R.
    Boutin, Celine
    Saleem, Ammar
    ENVIRONMENTAL POLLUTION, 2014, 189 : 134 - 142
  • [7] Calibration and field evaluation of polar organic chemical integrative sampler (POCIS) for monitoring pharmaceuticals in hospital wastewater
    Bailly, Emilie
    Levi, Yves
    Karolak, Sara
    ENVIRONMENTAL POLLUTION, 2013, 174 : 100 - 105
  • [8] Temperature dependence on the pesticide sampling rate of polar organic chemical integrative samplers (POCIS)
    Yabuki, Yoshinori
    Nagai, Takashi
    Inao, Keiya
    Ono, Junko
    Aiko, Nobuyuki
    Ohtsuka, Nobutoshi
    Tanaka, Hitoshi
    Tanimori, Shinji
    BIOSCIENCE BIOTECHNOLOGY AND BIOCHEMISTRY, 2016, 80 (10) : 2069 - 2075
  • [9] Polar organic chemical integrative sampler (POCIS) uptake rates for 17 polar pesticides and degradation products: laboratory calibration
    Ibrahim, Imtiaz
    Togola, Anne
    Gonzalez, Catherine
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2013, 20 (06) : 3679 - 3687
  • [10] Polar organic chemical integrative sampler (POCIS) uptake rates for 17 polar pesticides and degradation products: laboratory calibration
    Imtiaz Ibrahim
    Anne Togola
    Catherine Gonzalez
    Environmental Science and Pollution Research, 2013, 20 : 3679 - 3687