Background effects on Faraday collectors in gas-source mass spectrometry and implications for clumped isotope measurements

被引:118
|
作者
Bernasconi, Stefano M. [1 ]
Hu, Bin [1 ,2 ]
Wacker, Ulrike [3 ]
Fiebig, Jens [3 ,4 ]
Breitenbach, Sebastian F. M. [1 ]
Rutz, Tanja [3 ]
机构
[1] Swiss Fed Inst Technol, Inst Geol, CH-8092 Zurich, Switzerland
[2] Peking Univ, Dept Geog, Beijing 100871, Peoples R China
[3] Goethe Univ Frankfurt, Inst Geosci, Dept Paleontol, D-60438 Frankfurt, Germany
[4] Biodivers & Climate Res Ctr, D-60325 Frankfurt, Germany
关键词
CARBONATE MINERALS; C-13-O-18; BONDS; PALEOTHERMOMETER; THERMOMETRY; CO2;
D O I
10.1002/rcm.6490
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
RATIONALE The measurement of the abundances of minor isotopologues by mass spectrometry requires correction of subtle non-linearities in the mass spectrometer that cause deviations in the relationship between actual and measured isotope ratios. Here we show that negative backgrounds on the Faraday cups recording the minor ion beams are the cause of the observed non-linearities in the measurement of CO2 isotopologues, and propose a new correction procedure for clumped isotope measurements. METHODS We carefully investigated the cause of non-linearity effects in the measurement of the abundance of 13C18O16O, a minor isotopologue of CO2 with m/z 47, on two different mass spectrometers. By using gases of different composition with close to stochastic and with non-random distribution of isotopes we demonstrate that the apparent dependence of the excess abundance of the isotopologue of m/z 47 on the bulk isotopic composition of CO2 is due to a background interference that is linearly dependent on the partial pressure of the gas in the source of the mass spectrometer. CONCLUSIONS Background determination with gas flowing into the source of the mass spectrometer is necessary for accurate clumped isotope measurements of CO2. Background corrections can be performed accurately if the slit width of the m/z 44 Faraday cup significantly exceeds that of the one for m/z 47, using a correlation between m/z 44 signal intensity and the corresponding minimum in m/z 47 background. We propose two new correction schemes that reduce the time-consuming measurement of gases of different bulk isotopic compositions. These findings may also be relevant for the measurement of other rare isotopologues by mass spectrometry. Copyright (c) 2013 John Wiley & Sons, Ltd.
引用
收藏
页码:603 / 612
页数:10
相关论文
共 50 条
  • [41] Detection of exogenous GHB in blood by gas chromatography-combustion-isotope ratio mass spectrometry: Implications in postmortem toxicology
    Saudan, C
    Augsburger, M
    Kintz, P
    Saugy, M
    Mangin, P
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 2005, 29 (08) : 777 - 781
  • [42] Comparison of gas chromatography and liquid chromatography mass spectrometric measurements for high accuracy analysis of cholesterol in human serum by isotope dilution mass spectrometry
    Briche, CSJW
    Carter, D
    Webb, KS
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (09) : 848 - 853
  • [43] Effects of Acid and Concentration on Cu and Zn Isotope Measurements by Multicollector-Inductively Coupled Plasma Mass Spectrometry
    Li Jin
    Zhu Xiang-Kun
    Tang Suo-Han
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2008, 36 (09) : 1196 - 1200
  • [44] Influence of laser parameters on isotope fractionation and optimisation of lithium and boron isotope ratio measurements using laser ablation-multiple Faraday collector-inductively coupled plasma mass spectrometry
    Kimura, Jun-ichi
    Chang, Qing
    Ishikawa, Tsuyoshi
    Tsujimori, Tatsuki
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (11) : 2305 - 2320
  • [45] Simplified absolute metabolite quantification by gas chromatography-isotope dilution mass spectrometry on the basis of commercially available source material
    Vielhauer, Oliver
    Zakhartsev, Maksim
    Horn, Thomas
    Takors, Ralf
    Reuss, Matthias
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (32): : 3859 - 3870
  • [46] QUANTITATIVE MEASUREMENTS VIA CO-ELUTION AND DUAL-ISOTOPE DETECTION BY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY
    THOMAS, LC
    WEICHMANN, W
    [J]. JOURNAL OF CHROMATOGRAPHY, 1991, 587 (02): : 255 - 262
  • [47] GAS-CHROMATOGRAPHY ISOTOPE RATIO MASS-SPECTROMETRY MEASUREMENTS OF SOME CARBOXYLIC ESTERS FROM DIFFERENT APPLE VARIETIES
    KARL, V
    DIETRICH, A
    MOSANDL, A
    [J]. PHYTOCHEMICAL ANALYSIS, 1994, 5 (01) : 32 - 37
  • [48] High-precision Cu and Zn isotope analysis by plasma source mass spectrometry - Part 2. Correcting for mass discrimination effects
    Mason, TFD
    Weiss, DJ
    Horstwood, M
    Parrish, RR
    Russell, SS
    Mullane, E
    Coles, BJ
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (02) : 218 - 226
  • [49] High-precision Cu and Zn isotope analysis by plasma source mass spectrometry Part 2. Correcting for mass discrimination effects
    [J]. Mason, T.F.D. (thomas.mason@ic.ac.uk), 1600, Royal Society of Chemistry (19):
  • [50] Application of gas chromatography-isotope ratio mass spectrometry to source coal-derived polycyclic aromatic hydrocarbons in the environment.
    McRae, C
    Ioannou, A
    Sun, C
    Snape, CE
    Fallick, AE
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1998, 216 : U760 - U760