Evaluation of the RealStar® SARS-CoV-2 RT-PCR kit RUO performances and limit of detection

被引:36
|
作者
Visseaux, Benoit [1 ,2 ]
Le Hingrat, Quentin [1 ,2 ]
Collin, Gilles [1 ,2 ]
Ferre, Valentine [1 ,2 ]
Storto, Alexandre [1 ,2 ]
Ichou, Houria [1 ]
Bouzid, Donia [2 ,3 ]
Poey, Nora [4 ]
de Montmollin, Etienne [5 ]
Descamps, Diane [1 ,2 ]
Houhou-Fidouh, Nadhira [1 ]
机构
[1] Univ Paris, Hop Bichat, AP HP, Serv Virol, Paris, France
[2] Univ Paris, INSERM, DeSCID Decis SCi Infect Dis Control & Care, UMR 1137,IAME, Paris, France
[3] Univ Paris, Hop Bichat, AP HP, Serv Accueil Urgences, Paris, France
[4] Univ Paris, Hop Bichat, AP HP, Serv Malad Infect & Trop, Paris, France
[5] Univ Paris, Hop Bichat, AP HP, Reanimat Med & Infect, Paris, France
关键词
SARS-CoV-2; COVID-19; RT-PCR; Sensitivity;
D O I
10.1016/j.jcv.2020.104520
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Background: The use of efficient, reliable and sensitive PCR assays is a cornerstone in the race to contain the SARS-CoV-2 pandemic. In this work we performed an independent evaluation of the RealStar (R) SARS-CoV-2 RTPCR Kit Researh Use Only (Altona) for SARS-CoV-2 detection. Methods: A comparative limit of detection (LoD) assessment was performed between RealStar (R) SARS-CoV-2 and the currently WHO recommended RT-PCR (WHO-PCR) workflow using a quantified clinical sample. Assessment of the RealStar (R) SARS-CoV-2 assay was also performed using 83 primary clinical samples in comparison with the WHO-PCR. Results: The RealStar (R) SARS-CoV-2 demonstrated a slightly higher sensitivity than the WHO recommended assay with a limit of detection at 625 copies/mL instead of 1250 copies/mL for the WHO-PCR in our conditions. The overall percent agreement between RealStar (R) SARS-CoV-2 and WHO-PCR on 83 clinical samples was 97.6 % (81/83) with a sensitivity at 97.8 % (45/46) and specificity at 97.3 % (36/37). No cross reaction was encountered for the other human coronaviruses (HKU1, OC43, NL63, 229E). Conclusions: In this comparison of the RealStar (R) SARS-CoV-2 assay with the reference WHO assay, we observed a slightly better sensitivity of the RealStar (R) assay. It provides a robust option for all molecular biology laboratories, with a strong real-life LoD and is compatible with various real-time PCR platforms.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Comparison of FTD SARS-CoV-2 Assay and RealStar RT-PCR kit 1.0 for the detection of SARS-CoV-2
    Di Carlo, Daniele
    Mazzuti, Laura
    Sciandra, Ilaria
    Guerrizio, Giuliana
    Oliveto, Giuseppe
    Cabral, Rodolfo J. Riveros
    Zingaropoli, Maria Antonella
    Turriziani, Ombretta
    JOURNAL OF VIROLOGICAL METHODS, 2021, 298
  • [2] Multicenter comparison of the Cobas 6800 system with the RealStar RT-PCR kit for the detection of SARS-CoV-2
    Wirden, Marc
    Feghoul, Linda
    Bertine, Melanie
    Nere, Marie-Laure
    Le Hingrat, Quentin
    Abdi, Basma
    Boutolleau, David
    Ferre, Valentine Marie
    Jary, Aude
    Delaugerre, Constance
    Marcelin, Anne-Genevieve
    Descamps, Diane
    Legoff, Jerome
    Visseaux, Benoit
    Chaix, Marie-Laure
    JOURNAL OF CLINICAL VIROLOGY, 2020, 130
  • [3] Evaluation of RT-PCR assays for detection of SARS-CoV-2 variants of concern
    Sourav Dutta Dip
    Shovon Lal Sarkar
    Md. Ali Ahasan Setu
    Prosanto Kumar Das
    Md. Hasan Ali Pramanik
    A. S. M. Rubayet Ul Alam
    Hassan M. Al-Emran
    M. Anwar Hossain
    Iqbal Kabir Jahid
    Scientific Reports, 13
  • [4] Evaluation of RT-PCR assays for detection of SARS-CoV-2 variants of concern
    Dip, Sourav Dutta
    Sarkar, Shovon Lal
    Setu, Md. Ali Ahasan
    Das, Prosanto Kumar
    Pramanik, Md. Hasan Ali
    Alam, A. S. M. Rubayet Ul
    Al-Emran, Hassan M.
    Hossain, M. Anwar
    Jahid, Iqbal Kabir
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [5] Molecular diagnosis of SARS-CoV-2, performances and throughput by Direct RT-PCR
    Rigo, Silvia
    Durigon, Serena
    Basaglia, Giancarlo
    Avolio, Manuela
    De Rosa, Rita
    NEW MICROBIOLOGICA, 2021, 44 (03): : 173 - 176
  • [6] Microchip RT-PCR Detection of Nasopharyngeal SARS-CoV-2 Samples
    Cojocaru, Razvan
    Yaseen, Iqra
    Unrau, Peter J.
    Lowe, Christopher F.
    Ritchie, Gordon
    Romney, Marc G.
    Sin, Don D.
    Gill, Sikander
    Slyadnev, Maxim
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2021, 23 (06): : 683 - 690
  • [7] Establishment of a quantitative RT-PCR detection of SARS-CoV-2 virus
    Jiang, Yushen
    Zhang, Shanming
    Qin, Hong
    Meng, Shuai
    Deng, Xuyi
    Lin, He
    Xin, Xiaoliang
    Liang, Yuxin
    Chen, Bowen
    Cui, Yan
    Su, Yiheng
    Liang, Pei
    Zhou, Guangzhi
    Hu, Hongbo
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2021, 26 (01)
  • [8] Establishment of a quantitative RT-PCR detection of SARS-CoV-2 virus
    Yushen Jiang
    Shanming Zhang
    Hong Qin
    Shuai Meng
    Xuyi Deng
    He Lin
    Xiaoliang Xin
    Yuxin Liang
    Bowen Chen
    Yan Cui
    YiHeng Su
    Pei Liang
    GuangZhi Zhou
    Hongbo Hu
    European Journal of Medical Research, 26
  • [9] Detection of SARS-CoV-2 RNA in Bivalve Mollusks by Droplet Digital RT-PCR (dd RT-PCR)
    Mancusi, Andrea
    Capuano, Federico
    Girardi, Santa
    Di Maro, Orlandina
    Suffredini, Elisabetta
    Di Concilio, Denise
    Vassallo, Lucia
    Cuomo, Maria Concetta
    Tafuro, Maria
    Signorelli, Daniel
    Pierri, Andrea
    Pizzolante, Antonio
    Cerino, Pellegrino
    La Rosa, Giuseppina
    Proroga, Yolande Therese Rose
    Pierri, Biancamaria
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (02)
  • [10] The Dynamics of SARS-CoV-2 (RT-PCR) Testing
    Joyce, Nicole
    Seim, Lynsey
    Smerina, Michael
    CASE REPORTS IN MEDICINE, 2021, 2021